Dometic FreshWell2000 Návod na obsluhu

Typ
Návod na obsluhu

Táto príručka je tiež vhodná pre

Dometic WAECO International GmbH
Hollefeldstrasse 63
D-48282 Emsdetten
www.dometic.com
A
C
B
D
Ø
32 mm
100 mm
69 mm
128 mm
41 mm
135 mm
41 mm
B
C
A
A
B
A
B
B
Ø 32 mm
A
D
RAI
N H
O
L
E
O
UT
L
E
T
I
N
L
E
T
I
NL
E
T
Freshwell 2000
D
RA
I
N
H
O
L
E
O
UT
L
E
T
I
N
L
E
T
I
N
L
E
T
Freshwell 2000
D
R
A
I
N
H
O
L
E
O
U
T
L
E
T
I
N
L
E
T
I
N
L
E
T
Freshwell 2000
1 2
3
4
5
6
7
89
FreshWell2000
1
2
6
3
4
5
4445100686 F 05/2016
IR LIN1 LIN2
POWER
59 mm
X + 29,5 mm
X
50 mm
Y
93,5 mm
Y + 47
21
N1
N1 N2
sw
ws
sw
rt
ws
NO
COM
NF
bl
bl
br
N3
CN1 CN2
G/Y
G/Y
G/Y
RS
220~240 V 50 Hz
O.L.
LIN 1LIN 2CNA2
CN1
SW1
CNA1
CN10
CN7
6
5
7
2
1
3
4
a
b
DE EN FR ES IT NL DA SV NO FI PT RU PL CS SK HU
bl Blau Blue Bleu Azul Blu Blauw Blå Blå Blå Sininen Azul Синий Niebieski Modrá Modrá Kék
br Braun Brown Marron Marrón Marrone Bruin Brun Brun Brun Ruskea Castanho Коричневый Brązowy Hněda Hnedá Barna
cy Cyan Cyan Cyan Cian Cyan Cyaan Cyan Cyan Cyan Syaani Ciano Голубой Cyjan Azurová Azúrová Cián
ge Gelb Yellow Jaune Amarillo Giallo Geel Gul Gul Gul Keltainen Amarelo Желтый Żółty Žlutá Žltá Sárga
gn Grün Green Vert Verde Verde Groen Grøn Grön Grønn Vihreä Verde Зеленый Zielony Zelená Zelená Zöld
gr Grau Grey Gris Gris Grigio Grijs Grå Grå Grå Harmaa Cinzento Серый Szary Šedá Sivá Szürke
or Orange Orange Orange Naranja Arancione Oranje Orange Orange Oransje Oranssi Cor de laranja Оранжевый Pomarańczowy Oranžová Oranžová Narancs
pk Pink Pink Rosa Rose Rosa Roze Lysede Rosa Rosa Pinkki Cor de rosa Розовый żowy Růžová Ružová Rózsaszín
rt Rot Red Rouge Rojo Rosso Rood Rød Röd Rød Punainen Vermelho Красный Czerwony Červená Červená Piros
sw Schwarz Black Noir Negro Nero Zwart Sort Svart Svart Musta Preto Черный Czarny Černá Čierna Fekete
vt Violett Violet Violeta Lila Violetto Paars Violet Violett Fiolett Violetti Violeta Фиолетовый Fioletowy Fialová Fialová Ibolya
ws Weiß White Blanc Blanco Bianco Wit Hvid Vit Hvit Valkoinen Branco Белый Biały Bílá Biela Fehér
08
97
Under-bench air conditioner
Installation Manual. . . . . . . . . . . . . . . 3
Staukastenklimaanlage
Montageanleitung . . . . . . . . . . . . . . 17
Climatiseur de coffre
Instructions de montage . . . . . . . . . 33
Equipo de aire acondicionado
de cajón
Instrucciones de montaje. . . . . . . . . 49
Climatizzatore per vano di
carico
Indicazioni di montaggio . . . . . . . . . 65
Airco onder de bank
Montagehandleiding . . . . . . . . . . . . 81
Klimaanlæg til montering i et
magasin
Monteringsvejledning. . . . . . . . . . . . 97
Klimatanläggning för
förvaringsutrymmen
Monteringsanvisning . . . . . . . . . . . 110
Takboksklimaanlegg
Monteringsanvisning . . . . . . . . . . . 124
Kaappi-ilmastointilaite
Asennusohje . . . . . . . . . . . . . . . . . 137
Sistema de climatização para
caixa de arrumação
Instruções de montagem . . . . . . . . 150
Встраиваемый в багажный
ящик кондиционер
Инструкция по монтажу . . . . . . . . 166
EN
DE
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
Klimatyzator umieszczany
w schowku
Instrukcja montażu . . . . . . . . . . . . 182
Klimatizace do zavazadlového
prostoru
Návod k montáži . . . . . . . . . . . . . . 198
Klimatizačné zariadenie do
úložného priestoru
Návod na montáž . . . . . . . . . . . . . .211
Tárolóládás klímaberendezés
Szerelési útmutató . . . . . . . . . . . . 225
PL
CS
SK
HU
Dometic
FreshWell2000
EN
FreshWell2000 Explanation of symbols
3
Please read this instruction manual carefully before installation and
first use, and store it in a safe place. If you pass on the product to
another person, hand over this instruction manual along with it.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety and installation instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Target group for this instruction manual . . . . . . . . . . . . . . . . . . . . . . 6
4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1 Explanation of symbols
!
!
A
I
WARNING!
Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to
injury.
NOTICE!
Failure to observe this instruction can cause material damage and
impair the function of the product.
NOTE
Supplementary information for operating the product.
EN
Safety and installation instructions FreshWell2000
4
2 Safety and installation instructions
Please observe the prescribed safety instructions and stipulations
from the vehicle manufacturer and service workshops.
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and excess
voltage
Alterations to the product without express permission from the manu-
facturer
Use for purposes other than those described in the operating manual
Note the following basic safety information when using electrical devices to
protect against:
Electric shock
Fire hazards
Injury
2.1 Handling the device
!
WARNING!
Installation and repair of the under-bench air conditioner may
only be carried out by qualified personnel who are familiar with
the risks involved and the relevant regulations. Inadequate
repairs may cause serious hazards. For repair service, please
contact the service centre in your country (addresses on the
back page).
Electrical devices are not toys.
Keep electrical devices out of reach of children or infirm per-
sons. Do not allow them to use electrical devices without super-
vision.
Persons whose physical, sensory or mental capabilities or
whose lack of experience and knowledge prevent them from
using the device safely should not use it without supervision or
instruction by a responsible person.
In the event of a fire only use approved extinguishing agents.
Do not use water to extinguish fires.
EN
FreshWell2000 Safety and installation instructions
5
!
CAUTION!
The under-bench air conditioner must be installed securely so
that it cannot fall down.
Only operate the under-bench air conditioner if you are certain
that the housing and the cables are not damaged.
Do not use the under-bench air conditioner near flammable
fluids.
Make sure no combustible objects are stored or installed near
the air outlet. A distance of at least 50 cm must be kept.
Do not reach into air outlets or insert any foreign objects in the
device.
A
NOTICE!
Only use the device as intended.
The under-bench air conditioner is not suitable for use in agri-
cultural or construction vehicles.
Do not make any alterations or conversions to the device.
If faults occur in this refrigerant circuit, the system must be
checked by a specialist company and repaired properly. The
refrigerant must never be released into the air.
2.2 Handling electrical cables
!
WARNING!
The electrical power supply may only be connected by a
qualified electrician (e.g. VDE 0100, Part 721 in Germany).
!
CAUTION!
Fit a fuse of at least 10 amps to the connection with the vehicle’s
power supply.
Attach and lay the cables so that they cannot be tripped over or
damaged.
A
NOTICE!
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive
materials (metal).
Do not pull on the cables.
EN
Target group for this instruction manual FreshWell2000
6
3 Target group for this instruction
manual
The instructions in this manual are intended for qualified personnel at work-
shops who are familiar with the guidelines and safety precautions to be
applied.
4 Scope of delivery
No. in fig. 1 Number Description
1 1 under-bench air conditioner
2 1 Remote control
31Receiver
44Air filter
5 2 Angle section
6 4 Fastening bracket
7 14 Fastening screw
8 2 Drain pipe
9 2 Air purifying net
1 Assembly template
EN
FreshWell2000 Intended use
7
5 Intended use
The Dometic FreshWell2000 under-bench air conditioner (item no.
9105306418) is designed for use in motorcaravans, caravans and other vehi-
cles with habitation compartments only. It is not suitable for houses and
appartments.
The under-bench air conditioner is not suitable for installation in construction
machines, agricultural machines or similar equipment. It will not work prop-
erly if exposed to strong vibrations.
The operating mode of FreshWell2000 is guaranteed for temperatures
between 0 °C and 43 °C.
I
6Labels
Labels are attached to the Dometic FreshWell under-bench air conditioners.
These labels provide the user and fitter with information on specifications of
the device.
NOTE
You can find additional information on under-bench air condition-
ers in the operating manual, such as the technical description or
the controls.
EN
Installation FreshWell2000
8
7 Installation
!
7.1 Note on installation
Read this installation manual completely before installing the under-bench air
conditioner.
The following tips and instructions must be observed while installing the
under-bench air conditioner:
D
!
A
Note on transport
Always have someone help you carry the under-bench air conditioner.
Always lift the under-bench air conditioner to move it and never drag it
over the floor (fig. 2 A).
Do not use the ventilation slots to lift it (fig. 2 B).
CAUTION! Beware of injury
The under-bench air conditioner may only be installed by qualified
personnel from a specialist company. The following information is
intended for technicians who are familiar with the guidelines and
safety precautions to be applied.
DANGER! Danger of electrocution
Disconnect all power supplies when working on the under-bench
air conditioner.
CAUTION! Beware of injury
Improper installation of the under-bench air conditioner can
result in irreparable damage to the device and put the safety of
the user at risk.
The manufacturer assumes no liability for malfunctions and for
the safety of the under-bench air conditioner, especially for
injury and/or damage to property, if the under-bench air condi-
tioner is not fitted in accordance with these installation instruc-
tions.
Always wear the recommended protective clothing
(e.g. protective goggles, gloves).
NOTICE! Beware of damage
Observe the structural engineering of the vehicle and seal of all
openings made when installing the under-bench air conditioner.
EN
FreshWell2000 Installation
9
Note on installation location
To install the machine it is necessary to create openings in the floor.
These openings must be accessible and must not be covered by any
parts of the vehicle.
Before installing the under-bench air conditioner, check whether any vehi-
cle components could be damaged by the installation of the under-bench
air conditioner (such as lamps, cupboards, doors).
Make sure no combustible objects are stored or installed near the air out-
let. A distance of at least 50 cm should be kept.
The inclination of the installation surface may not exceed 10°.
For safety reasons, note the location of existing wiring harnesses, wires
and other components within the installation area, in particular those
which are not visible, when installing the under-bench air conditioner
(when drilling or screwing etc.).
To obtain the optimal air-conditioning in the vehicle, install the under-
bench air conditioner in a central position, in a compartment or a similar
housing.
Choose a place that is easily accessible for servicing as well as disassem-
bling and installing.
Place the assembly template into the chosen compartment and check the
space available for the openings in the floor.
To minimize the transmission of noise and vibration during operation, the
under-bench air conditioner should have a all around minimum clearance
of 30 mm to walls and furniture.
The under-bench air conditioner must be installed on the floor.
Keep a distance of 200 mm between the front of the under-bench air
conditioner and the walls of the compartment to facilitate filter replace-
ment.
Installing the under-bench air conditioner into an external compartment
(e.g. false bottoms), the air to be treated must be drawn in from the vehi-
cle’s passenger compartment.
Suctioning of outside air can significantly reduce the power of the system.
EN
Installation FreshWell2000
10
Note on electrical system (see fig. b)
Only a qualified electrician should connect the under-bench air condi-
tioner to the electrical power.
Check that the voltage specification on the type plate is the same as that
of the power supply.
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
Install an all-pole switch with a contact opening width of at least 3 mm on
the installation side.
7.2 Making openings
See fig. 3
Mark the position and size of the openings using the template included in
the packaging (A and B).
See fig. 4
Drill out the corners (A).
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
Make sure no electrical power cables are damaged.
Drill out a condensation water drainage opening with a diameter of
32 mm (C).
See fig. 5
Mark the position of the angle sections (A) and the fastening brackets (B).
No. in fig. b Description
1 Motor ventilator (inner)
2 Motor ventilator (outer)
3 Capacitor
4 Compressor
5 Temperature sensor
6PCB
7 PCB Display
EN
FreshWell2000 Installation
11
7.3 Installing the fastening brackets and the belts
See fig. 6
Fasten the four fastening brackets (A).
Pull the belts through the fastening brackets (B).
Install the drain pipe under the under-bench air conditioner (C).
Fasten the under-bench air conditioner with the belts (D).
7.4 Installing the angle section
See fig. 7
Fasten the under-bench air conditioner with the two angle sections an
three fastening screw for each as shown.
7.5 Installing the receiver
See fig. 8
Drill an opening of 50 mm into the wall.
See fig. 9
Lay the cable through the hole to the under-bench air conditioner.
Fasten the receiver as shown.
7.6 Laying the connecting cables
D
The under-bench air conditioner must be connected to an electric circuit
which is able to supply the required current (see chapter “Technical data” on
page 16).
Select the cross-section of the cable corresponding to the length:
Length < 7.5 m: 1.5 mm²
Length > 7.5 m: 2.5 mm²
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
EN
Installation FreshWell2000
12
See fig. 0
Plug the four-pole plug of the receiver into the IR socket of the (1)
Plug the 230 Vw plug into an 230 Vw socket (2).
7.7 Air ducting
See fig. a
Make the air ducting with trade parts (not included in the supply). It is recom-
mended to use cardboard pipe for air conditioning with an aluminium core
and external covering of PVC. The nominal inside diameter should size up to
60 mm, the outside diameter 65 mm.
The ventilation pipes are joined by pressing them together thanks to the
tapered hole on the air outlet.
The pipes can be connected either on the outlet on the coil side or, by remov-
ing the guard and closing the front holes, on the side outlet.
To achieve the best efficiency it is recommended to:
lay the air pipes as short and straight as possible
restrict the legth of the pipes to 5 m
don‘t lay the pipes near any heat sources
The recirculation air is drawn in through a grille or through other openings
with a total cross-section of at least 300 cm². The recirculation air opening
must be created near the machine. If this is not possible, make sure that the
air flow must be obstructed by anything; if necessary, create an air duct
between the opening and the machine.
The recirculation air must be taken from inside the passenger compartment;
if taken from the outside then the efficiency of the under-bench air conditioner
will be reduced.
EN
FreshWell2000 Troubleshooting
13
8 Troubleshooting
Problem Cause Remedy
No cooling
capacity
The under-bench air conditioner is
not set to cooling.
Set the under-bench air condi-
tioner to cooling.
The ambient temperature is above
43 °C.
The under-bench air conditioner is
only designed for ambient temper-
atures of up to 43 °C.
The temperature set is higher that the
room temperature.
Select a lower temperature.
The ambient temperature is below
16 °C.
The under-bench air conditioner is
only designed for ambient temper-
atures above 16 °C.
The thermal protection is defective.
Contact an authorised work-
shop.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
Low air output The air filter is obstructed.
Clean the air filter.
The heat exchange coils are polluted.
Contact an authorised work-
shop.
The internal blower is defective.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
Clean the drainage openings
for condensation water.
The seals are damaged.
Contact an authorised work-
shop.
EN
Disposal FreshWell2000
14
9 Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and
control the influence that their activities (manufacturing, products, services,
etc.) have on the environment.
The procedures to be followed to identify significant environmental impact
must take the following factors into account:
use of raw materials and natural resources
atmospheric emissions
discharge of liquids
waste management and recycling
contamination of the soil
Under-bench air
conditioner does
not switch on.
No supply voltage (230 Vw)
connected.
Check the power supply.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
Contact an authorised work-
shop.
The defective thermal protection is
defective.
The electrical fuse of the power
supply is too low.
Check the electrical fuse of the
power supply.
Under-bench air
conditioner stops
working.
The air filter is obstructed.
Clean the air filter.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
Contact an authorised work-
shop.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
conditioner does
not switch off.
One of the temperature sensors is
defective.
Contact an authorised work-
shop.
Problem Cause Remedy
EN
FreshWell2000 Disposal
15
In order to minimise environmental impact, the manufacturer provides a
series of indications here below that should be taken into account by all those
who, for whatever reason, interact with the appliance during its working life.
All packing components must be disposed of (preferably recycled) in com-
pliance with statutory legislation in the country in which disposal takes
place.
All product components must be disposed of (preferably recycled) in com-
pliance with statutory legislation in the country in which disposal takes
place.
For correct disposal, the appliance must be consigned to an authorised
waste disposal company to ensure that all recyclable components are
reused and the remaining materials are processed properly.
During installation ensure the room has adequate ventilation to prevent
the build-up of stale air that might be harmful to the health of the opera-
tors.
During operation and maintenance ensure that any waste pollutant prod-
ucts (oil, grease, etc.) are disposed of correctly.
Keep noise levels down to reduce noise pollution.
For more information on correct dismantling of our products please refer to
the recycling handbooks at www.dometic.com.
Place the packaging material in the appropriate recycling waste bins
wherever possible.
When in operation or undergoing repairs and maintenance work, make
sure that the refrigerant circuit is not damaged and refrigerant cannot
escape. It acts as a greenhouse gas and should not be allowed into the
environment.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Dispose of the product at an official waste disposal facility in accordance
with the applicable recycling or disposal guidelines.
B
Protect the environment!
Do not dispose of any batteries with general household waste.
Return defective or used batteries to your retailer or dispose of
them at collection points.
EN
Technical data FreshWell2000
16
10 Technical data
Dometic FreshWell2000
Item no.: 9105306418
Compressor cooling capacity: 1800 W
Rated input voltage: 230 Vw/ 50 Hz
Current consumption: 2.8 A
Operating temperature range: 0 °C to +43 °C
Refrigerant: R-407C
Blower: 3 blower levels
1 Automatic mode
Protection class: IP X5
Max. volume of space in the vehicle
(with insulated walls): 30 m³
Dimensions L x W x H: 560 x 400 x 286 mm
Weight: approx. 20 kg
Inspection/certification:
560 400
286
10R-053561
4
DE
FreshWell2000 Erklärung der Symbole
17
Bitte lesen Sie diese Anleitung vor Einbau und Inbetriebnahme sorg-
fältig durch und bewahren Sie sie auf. Geben Sie sie im Falle einer
Weitergabe des Produktes an den Nutzer weiter.
Inhaltsverzeichnis
1 Erklärung der Symbole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2 Sicherheits- und Einbauhinweise. . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3 Zielgruppe dieser Anleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4 Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Bestimmungsgemäßer Gebrauch . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6 Kennzeichnungsschilder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7 Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8 Störungsbeseitigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
9 Entsorgung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
10 Technische Daten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
1 Erklärung der Symbole
!
!
A
I
WARNUNG!
Sicherheitshinweis: Nichtbeachtung kann zu Tod oder schwerer
Verletzung führen.
VORSICHT!
Sicherheitshinweis: Nichtbeachtung kann zu Verletzungen
führen.
ACHTUNG!
Nichtbeachtung kann zu Materialschäden führen und die
Funktion des Produktes beeinträchtigen.
HINWEIS
Ergänzende Informationen zur Bedienung des Produktes.
DE
Sicherheits- und Einbauhinweise FreshWell2000
18
2 Sicherheits- und Einbauhinweise
Beachten Sie die vom Fahrzeughersteller und vom Kfz-Handwerk vor-
geschriebenen Sicherheitshinweise und Auflagen!
Der Hersteller übernimmt in folgenden Fällen keine Haftung für Schäden:
Beschädigungen am Produkt durch mechanische Einflüsse und Über-
spannungen
Veränderungen am Produkt ohne ausdrückliche Genehmigung vom
Hersteller
Verwendung für andere als die in der Anleitung beschriebenen Zwecke
Beachten Sie folgende grundsätzliche Sicherheitsmaßnahmen beim
Gebrauch von elektrischen Geräten zum Schutz vor:
elektrischem Schlag
Brandgefahr
Verletzungen
2.1 Umgang mit dem Gerät
!
WARNUNG!
Die Montage und Reparaturen der Staukastenklimaanlage
dürfen nur von Fachkräften durchgeführt werden, die mit den
verbundenen Gefahren bzw. den einschlägigen Vorschriften
vertraut sind. Durch unsachgemäße Reparaturen können
erhebliche Gefahren entstehen. Wenden Sie sich im Reparatur-
fall an den Service-Stützpunkt in Ihrem Land (Adressen auf der
Rückseite).
Elektrogeräte sind kein Kinderspielzeug!
Kinder können Gefahren, die von elektrischen Geräten ausge-
hen, nicht richtig einschätzen. Lassen Sie Kinder nicht ohne
Aufsicht elektrische Geräte benutzen.
Personen, die aufgrund ihrer physischen, sensorischen oder
geistigen Fähigkeiten oder ihrer Unerfahrenheit oder Unkennt-
nis nicht in der Lage sind, das Gerät sicher zu benutzen, sollten
dieses Gerät nicht ohne Aufsicht oder Anweisung durch eine
verantwortliche Person nutzen.
Im Falle von Feuer verwenden Sie nur zugelassene Lösch-
mittel. Verwenden Sie kein Wasser zum Löschen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242

Dometic FreshWell2000 Návod na obsluhu

Typ
Návod na obsluhu
Táto príručka je tiež vhodná pre