Dometic FreshWell 2000 Návod na používanie

Typ
Návod na používanie

Tento návod je vhodný aj pre

Under-bench air conditioner
Operating manual . . . . . . . . . . . . . . . 7
Staukastenklimaanlage
Bedienungsanleitung . . . . . . . . . . . . 32
Climatiseur de coffre
Notice d’utilisation . . . . . . . . . . . . . . 57
Equipo de aire acondicionado
de cajón
Instrucciones de uso . . . . . . . . . . . . 82
Climatizzatore per vano di
carico
Istruzioni per l’uso . . . . . . . . . . . . . 107
Airco onder de bank
Gebruiksaanwijzing . . . . . . . . . . . . 133
Klimaanlæg til montering i et
magasin
Betjeningsvejledning . . . . . . . . . . . 158
Klimatanläggning för
förvaringsutrymmen
Bruksanvisning . . . . . . . . . . . . . . . 158
Takboksklimaanlegg
Bruksanvisning . . . . . . . . . . . . . . . 183
Kaappi-ilmastointilaite
Käyttöohje . . . . . . . . . . . . . . . . . . . 233
Sistema de climatização para
caixa de arrumação
Manual de instruções. . . . . . . . . . . 258
  
 
  . . . . 284
EN
DE
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
Klimatyzator umieszczany
w schowku
Instrukcja obsugi . . . . . . . . . . . . . .311
Klimatizace do zavazadlového
prostoru
Bruksanvisning . . . . . . . . . . . . . . . 336
Klimatizané zariadenie do
úložného priestoru
Käyttöohje. . . . . . . . . . . . . . . . . . . 361
Tárolóládás klímaberendezés
Használati utasítás . . . . . . . . . . . . 387
PL
CS
SK
HU
Dometic
FreshWell2000
FreshWell2000
3
1
2
3
4
1
5
1
2
3
4
2
FreshWell2000
4
+
-
MODE
°C
CLOCK
TIMER
SET - °F/°C
SET - °F/°C
SLEEP
R
OOM
DIM
DIM
P.F.
P.F.
LIGHT
08:00
ON
20:00
OFF
1
10
11
12
13
14
15
16
17
18
2
3
4
5
6
7
8
9
3
1
23 4
1
4
FreshWell2000
5
1
2
5
1
6
FreshWell2000
6
560 400
59 33
286
93,5
7
EN
FreshWell2000
7
Please read this instruction manual carefully before first use, and store
it in a safe place. If you pass on the product to another person, hand
over this instruction manual along with it.
Table of contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2 Receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.4 Air conditioning modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.5 Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8 Operating the under-bench air conditioner. . . . . . . . . . . . . . . . . 19
8.1 Basic notes on operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8.2 Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8.3 Hint for improved use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8.4 Switching the under-bench air conditioner on and off . . . . . . 20
8.5 Selecting the air conditioning mode. . . . . . . . . . . . . . . . . . . . 21
8.6 Selecting the blower setting manually . . . . . . . . . . . . . . . . . . 21
8.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.8 Setting the timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.9 Activating the Sleep function . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.10 Replacing the remote control batteries . . . . . . . . . . . . . . . . . 24
8.11 Setting the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9 Cleaning the under-bench air conditioner. . . . . . . . . . . . . . . . . . 25
10 Maintenance of the under-bench air conditioner . . . . . . . . . . . . 26
EN
Explanation of symbols FreshWell2000
8
11 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
14 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1 Explanation of symbols
!
!
A
I
WARNING!
Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to
injury.
NOTICE!
Failure to observe this instruction can cause material damage and
impair the function of the product.
NOTE
Supplementary information for operating the product.
EN
FreshWell2000 Safety instructions
9
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
z Damage to the product resulting from mechanical influences and excess
voltage
z Alterations to the product without express permission from the manu-
facturer
z Use for purposes other than those described in the operating manual
In particular, the manufacturer will not be liable for any consequential
damage, especially consequential damage caused by failure of the under-
bench air conditioner.
Note the following basic safety information when using electrical devices to
protect against:
z Electric shock
z Fire hazards
z Injury
2.1 General safety
!
WARNING!
z Electrical devices are not toys.
Keep electrical appliances out of reach of children or infirm
persons. Do not let them use the appliances without super-
vision.
z Persons whose physical, sensory or mental capabilities or
whose lack of experience and knowledge prevent them from
using the device safely should not use it without supervision or
instruction by a responsible person.
z Only use the device as intended.
z Do not make any alterations or conversions to the device.
z Installation, maintenance and repairs of the under-bench air
conditioner may only be carried out by qualified personnel who
are familiar with the risks involved when handling refrigerant
and air conditioning systems as well as the relevant regulations.
Inadequate repairs may cause serious hazards. For repair
service, please contact the service centre in your country
(addresses on the back page).
EN
Target group for this manual FreshWell2000
10
z Do not use the under-bench air conditioner near flammable
fluids.
z Make sure no combustible objects are stored or installed near
the air outlet. A distance of at least 50 cm must be kept.
z Do not reach into air outlets or insert any foreign objects in the
under-bench air conditioner.
z Do not undo the upper cover of the under-bench air conditioner
in the event of a fire. Use approved extinguishing agents
instead. Do not use water to extinguish fires.
A
NOTICE!
z If faults occur in the under-bench air conditioner's refrigerant
circuit, the under-bench air conditioner must be checked by a
specialist company and properly repaired. The refrigerant must
never be released into the air.
2.2 Operating the device safely
!
WARNING!
z Always disconnect the power supply when working on the
device.
A
NOTICE!
z The under-bench air conditioner is not suitable for use in agri-
cultural or construction vehicles.
z Operate the device only if you are certain that the housing and
the cables are undamaged.
3 Target group for this manual
This operating manual is for the user of the under-bench air conditioner.
EN
FreshWell2000 Scope of delivery
11
4 Scope of delivery
5 Intended use
The Dometic FreshWell2000 under-bench air conditioner (item no.
9105306418) is designed for use in motorcaravans, caravans and other vehi-
cles with habitation compartments only. It is not suitable for houses and
appartments.
The under-bench air conditioner is not suitable for installation in construction
machines, agricultural machines or similar equipment. It will not work prop-
erly if exposed to strong vibrations.
The operating mode of FreshWell2000 is guaranteed for temperatures
between 0 °C and 43 °C.
6 Technical description
The under-bench air conditioner supplies the interior with cool dehumidified
air without dust and dirt.
The under-bench air conditioner is operated with the remote control.
I
Designation Item number
Dometic FreshWell under-bench air conditioner 9105306418
Installation manual
Operating manual
NOTE
The under-bench air conditioner can lower the temperature within
the vehicle to a certain level. The temperature depends on the
type of vehicle, the ambient temperature and the cooling capacity
of your under-bench air conditioner.
Below an outer temperature of 16 °C the under-bench air condi-
tioner doesn’t cool anymore. In this case only use the air condi-
tioning mode “Circulating air” ( ).
EN
Technical description FreshWell2000
12
6.1 Components
The refrigerant circuit of the under-bench air conditioner consists of the
following main components (fig. 1, page 3):
z Compressor (1)
The compressor draws in the refrigerant used and compresses it. This
raises the pressure and therefore the temperature of the refrigerant.
z Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flow-
ing past absorbs the heat and the hot refrigerant gas cools down and
becomes liquid.
z Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them.
The refrigerant absorbs the heat and vaporises.
z Blower (4)
A blower distributes the cooled or heated air within the vehicle through
an air outlet unit.
EN
FreshWell2000 Technical description
13
6.2 Receiver
The receiver (fig. 2, page 3) contains the following control and display
elements:
In case of an alarm the display shows an error code to identify the fault:
No. Explanation
1 Digital display Displays the room temperature.
2 Red/green LED Constantly lit, red: the stand-by mode is active.
Constantly lit, green: any other mode is active.
Flashing, red/green: the under-bench air conditioner is
on, but the supply voltage is not present.
3 Blue LED Constantly lit: the cooling mode is active.
Flashing: the dehumidification mode is active.
Off: any other mode is active.
4 Orange LED Constantly lit: the heat pump mode is active.
Flashing: the heat pump mode is active, but the air
conditioner is not yet producing hot air, because the
defrost function or the preventing cold air function is
active.
The defrost function prevents ice on the external battery
exchanger while in heat pump mode.
The preventing cold air function prevents that cold air is
blown into the vehicle while in heat pump mode.
Off: any other mode is active.
5 Yellow LED Constantly lit: the timer mode is active.
Off: the timer mode is not active.
Code Explanation
E1 Room temperature probe fault
E2 Indoor battery temperature probe fault
E4 Control card communication fault (control card failure)
EN
Technical description FreshWell2000
14
6.3 Remote control
All settings of the device (e. g. temperature settings, timer programming) are
transmitted to the under-bench air conditioner by remote control.
The following control and display elements are available on the remote
control (fig. 3, page 4) :
No. Explanation
1 Digital display:
displays the following:
–Time
Selected room temperature (target value) in °C or °F
Actual room temperature
Air conditioning mode
Blower level
Symbols for active additional functions
Battery status
2
Button :
Switches the under-bench air conditioner and remote control on or to
stand-by mode
3
Button :
Selects the blower setting
4 MODE button:
Selects the air conditioning mode
5 CLOCK button:
Sets the time
6 P. F. button:
No function assigned yet
7 TIMER button:
Sets the timer
8 SLEEP button:
Activates the sleep function. The sleep function automatically modifies the
target value to provide a pleasant sleeping temperature.
9 SET – °F/°C button:
Transmits current data to the under-bench air conditioner.
Confirms the time setting.
If temperature is displayed: switches between temperature units
Celsius (°C) and Fahrenheit (°F)
EN
FreshWell2000 Technical description
15
10 I FEEL button:
No function assigned yet
11 Reset button
Resets all values to standard values
12 ROOM button:
Press once:
Press again:
Displays the current interior temperature
(symbol is displayed).
Displays the set temperature.
13 LIGHT button:
No function assigned yet
14 DIM button:
No function assigned yet
15 button:
Reduces the value
16 + button:
Increases the value
17
Symbol (batteries empty)
Is displayed when the batteries in the remote control are empty. If this
happens, replace the batteries, see chapter “Replacing the remote control
batteries” on page 24.
18
Symbol (transmitting values)
Is displayed briefly when the remote control is transmitting values to the
under-bench air conditioner.
No. Explanation
EN
Technical description FreshWell2000
16
6.4 Air conditioning modes
The under-bench air conditioner has the following air conditioning modes:
Air condition-
ing mode
Display
message
Explanation
Automatic In this mode the under-bench air conditioner sets
the temperature (set point) automatically and
manages the compressor, heat pump and fan
speed by comparing the set point with the room
temperature and it sets the corresponding condi-
tioning mode (see following table).
The , + and buttons are deactivated in this
mode.
Cooling You specify the temperature and blower settings,
and the under-bench air conditioner cools the
interior to this temperature.
Circulating air You specify the blower level, and the under-
bench air conditioner blows air into the interior
.
Dehumidification You specify the temperature, and the under-
bench air conditioner cools the interior to this
temperature and controls the necessary blower
output and dehumidifys the interior (Circulating
air mode).
The button is deactivated in this mode.
Current room
temperature
ϑ
ϑ ≤
20 °C 20 °C <
ϑ
< 25 °C
ϑ
25 °C
Set point: 20 °C 22 °C 25 °C
Conditioning
mode:
Circulating air Dry mode Cooling
EN
FreshWell2000 Technical description
17
6.5 Additional functions
The under-bench air conditioner has the following additional functions:
Additional
function
Display
message
Explanation
Timer The under-bench air conditioner is switched on at
the specified time.
The under-bench air conditioner is switched off at
the specified time.
The under-bench air conditioner is switched on
and off at the specified times.
Sleep The set temperature is modified by 1 °C after one
hour and by 2 °C after two hours to generate a
pleasant temperature for sleeping.
08:00
20:00
08:00 20:00
EN
Before initial use FreshWell2000
18
7 Before initial use
Inspection before starting up
Before you switch on the under-bench air conditioner, observe the following:
Check whether the supply voltage and frequency correspond to the
values specified in the technical data, see page 31.
Ensure both the air intake opening and the air nozzles are free. All venti-
lation grilles must always be kept free to ensure that the under-bench air
conditioner is able to operate at maximum capacity.
!
Check remote control and insert batteries
Insert the provided batteries in the remote control battery compartment,
see chapter “Replacing the remote control batteries” on page 24.
Check that the four Dip switches (fig. 4 1, page 4) are in the correct
position.
If you changed the position of the Dip switches:
Acknowledge the new setting using the Reset button (fig. 3 11, page 4).
Setting the time
Set the current time: see chapter “Setting the time” on page 25.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the
intake grille.
EN
FreshWell2000 Operating the under-bench air conditioner
19
8 Operating the under-bench air
conditioner
8.1 Basic notes on operation
The under-bench air conditioner has three operating modes:
The receiver switches on when it receives pulses from the remote control.
The display shows (flashing) the temperature setting, after 10 seconds the
display shows the room temperature, then it switches off.
You can use the remote control to
z switch the under-bench air conditioner to and from stand-by mode.
z adjust the settings.
z select additional functions.
8.2 Using the remote control
The remote control must be pointed at the IR receiver (fig. 2 4, page 3) on
the receiver during operation.
When a button is pressed, the value is transmitted directly to the under-bench
air conditioner. The under-bench air conditioner confirms the receipt of data
with a high note.
Switching only the remote control to or from stand-by
In stand-by mode, the remote control display shows only the time.
If the remote control is not pointing to the IR receiver (fig. 2
4, page 3) on
the control panel, you can activate the remote control or switch it to stand-by
independently from the under-bench air conditioner:
Press the button.
Operating mode Features
Stand-by The under-bench air conditioner is ready for operation and can
be switched on with the remote control.
On The under-bench air conditioner is conditioning the air in the
interior.
EN
Operating the under-bench air conditioner FreshWell2000
20
8.3 Hint for improved use
The following hints will optimise the performance of your under-bench air
conditioner:
z Improve the heat insulation of your vehicle by sealing gaps and hanging
reflective blinds or curtains on your windows.
z If the vehicle has been subjected to direct sunlight for a long time: Operate
the under-bench air conditioner in the “Circulating air” ( ) mode with the
windows open for a while before switching on the “Cooling” ( ) air con-
ditioning mode.
z Avoid opening doors and windows as far as possible in the “Cooling” ( )
mode.
z Select an appropriate temperature and blower speed.
z Align the air nozzles sensibly.
z Make sure the air nozzles and intake grille are not covered by cloths,
paper or other objects.
z Clean the air filter periodically.
8.4 Switching the under-bench air conditioner on and
off
I
When you switch on the under-bench air conditioner, the device waits a few
minutes before operating the compressor.
NOTE
z When it is switched on, it begins to condition the air to the
values that were set most recently.
z You can use the remote control to switch the under-bench air
conditioner to and from stand-by mode. Press the button.
z You can operate the under-bench by remote control and via
LIN bus. If you use LIN bus control the receiver is not required.
z Don‘t use the under-bench air conditioner if the vehicle is tilted
more than 10°.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412

Dometic FreshWell 2000 Návod na používanie

Typ
Návod na používanie
Tento návod je vhodný aj pre