Dometic FreshWell FW3000 Návod na používanie

Typ
Návod na používanie

Tento návod je vhodný aj pre

FW3000
Under-bench air conditioner
Operating manual . . . . . . . . . . . . . . . . . . . . . 6
Staukastenklimaanlage
Bedienungsanleitung . . . . . . . . . . . . . . . . .30
Climatiseur de coffre
Notice d’utilisation . . . . . . . . . . . . . . . . . . .55
Equipo de aire acondicionado de
cajón
Instrucciones de uso . . . . . . . . . . . . . . . . . .79
Sistema de climatização para caixa
de arrumação
Manual de instruções . . . . . . . . . . . . . . . .104
Climatizzatore per vano di carico
Istruzioni per l’uso . . . . . . . . . . . . . . . . . . . 131
Airco onder de bank
Gebruiksaanwijzing. . . . . . . . . . . . . . . . . .156
Klimaanlæg til montering i et
magasin
Betjeningsvejledning . . . . . . . . . . . . . . . .180
Klimatanläggning för
förvaringsutrymmen
Bruksanvisning . . . . . . . . . . . . . . . . . . . . . 204
Takboksklimaanlegg
Bruksanvisning . . . . . . . . . . . . . . . . . . . . . 226
Kaappi-ilmastointilaite
Käyttöohje . . . . . . . . . . . . . . . . . . . . . . . . . 249
Встраиваемый в багажный ящик
кондиционер
Инструкция по эксплуатации . . . . . . . . . 272
Klimatyzator umieszczany
wschowku
Instrukcja obsługi . . . . . . . . . . . . . . . . . . . 297
Klimatizačné zariadenie do
úložného priestoru
Návod na obsluhu. . . . . . . . . . . . . . . . . . . 321
Klimatizace do zavazadlového
prostoru
Návod k obsluze . . . . . . . . . . . . . . . . . . . .345
Tárolóládás klímaberendezés
Használati utasítás. . . . . . . . . . . . . . . . . . . 368
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
AIR CONDITIONERS
FRESHWELL
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
FreshWell3000
2
1
2
6
5
3
4
7
8
9
10
4
1
5
1
2
3
4
2
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
FreshWell3000
3
1
7
6
13
12
15
14
2
4
3
11
10
9
5
8
3
1
2
4
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
FreshWell3000
4
1
2
1.
2.
4.
5.
3.
5
400
628
286
6
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
FreshWell3000
5
7
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000
6
Original instructions
Please read this instruction manual carefully before first use, and store it in
a safe place. If you pass on the product to another person, hand over this
instruction manual along with it.
You find the installation manual online at:
“dometic.com/manuals”.
The instructions in the installation manual are intended for qualified
personnel at workshops who are familiar with the guidelines and
safety precautions to be applied.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
6 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
6.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6.4 Air conditioning modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
6.5 Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
7 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
8 Operating the under-bench air conditioner. . . . . . . . . . . . . . . . . . . . .17
8.1 Basic notes on operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
8.2 Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
8.3 Hint for improved use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
8.4 Switching the under-bench air conditioner on and off . . . . . . . . . . .18
8.5 Selecting the air conditioning mode . . . . . . . . . . . . . . . . . . . . . . . . .18
8.6 Selecting the blower setting manually . . . . . . . . . . . . . . . . . . . . . . . .19
8.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
8.8 Setting the timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Explanation of symbols
7
8.9 Activating the Sleep function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.10 Replacing the remote control batteries . . . . . . . . . . . . . . . . . . . . . . 22
8.11 Setting the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9 Cleaning the under-bench air conditioner . . . . . . . . . . . . . . . . . . . . . 23
10 Maintenance of the under-bench air conditioner . . . . . . . . . . . . . . . 24
11 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
14 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1 Explanation of symbols
!
!
A
I
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and incorrect
connection voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Safety instructions FreshWell3000
8
In particular, the manufacturer will not be liable for any consequential damage,
especially consequential damage caused by failure of the under-bench air
conditioner.
Note the following basic safety information when using electrical devices to protect
against:
Electric shock
Fire hazards
Injury
2.1 General safety
!
WARNING!
Electrical devices are not toys.
Keep electrical devices out of reach of children or infirm persons. Do
not allow them to use electrical devices without supervision.
This device can be used by children aged 8 years or over, as well as by
persons with diminished physical, sensory or mental capacities or a
lack of experience and/or knowledge, providing they are supervised
or have been taught how to use the device safely and are aware of the
resulting risks.
Cleaning and user maintenance must not be carried out by children
without supervision.
Children must not play with the device.
Children must be supervised to ensure that they do not play with the
device.
Always keep and use the device out of the reach of children under the
age of 8 years.
Only use the device as intended.
Do not make any alterations or conversions to the device.
Installation, maintenance and repairs of the under-bench air
conditioner must only be carried out by qualified personnel who are
familiar with the risks involved when handling refrigerant and air
conditioning systems as well as the relevant regulations. Inadequate
repairs may cause serious hazards. For repair service, please contact
the service centre in your country (addresses on the back page).
Do not use the under-bench air conditioner near flammable fluids.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Target group for this manual
9
Make sure no combustible objects are stored or installed near the air
outlet. A distance of at least 50 cm must be kept.
Do not reach into air outlets or insert any foreign objects in the under-
bench air conditioner.
Do not undo the upper cover of the under-bench air conditioner in
the event of a fire. Use approved extinguishing agents instead. Do not
use water to extinguish fires.
A damaged supply cord must be replaced by the manufacturer or a
qualified person in order to avoid a hazard.
A
NOTICE!
If faults occur in the under-bench air conditioner's refrigerant circuit,
the under-bench air conditioner must be checked by a specialist com-
pany and properly repaired. The refrigerant must never be released
into the air.
Do not apply heavy objects or pressure on the device.
2.2 Operating the device safely
!
WARNING!
Always disconnect the power supply when working on the device.
!
CAUTION!
Do not touch the device during operation. The device contains hot
and cold components, moving parts and electrical items which may
cause injury.
A
NOTICE!
The under-bench air conditioner is not suitable for use in agricultural or
construction vehicles.
Operate the device only if you are certain that the housing and the
cables are undamaged.
3 Target group for this manual
This operating manual is for the user of the under-bench air conditioner.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Scope of delivery FreshWell3000
10
4Scope of delivery
Dometic FreshWell under-bench air conditioner
Operating manual
5 Intended use
The Dometic FreshWell3000 under-bench air conditioner is designed for use in
motorcaravans, caravans and other vehicles with habitation compartments only. It is
not suitable for houses and appartments.
The under-bench air conditioner is not suitable for installation in construction
machines, agricultural machines or similar equipment. It will not work properly if
exposed to strong vibrations.
The operating mode of FreshWell3000 is guaranteed for temperatures between
C and 5C.
6 Technical description
The under-bench air conditioner supplies the interior with cool dehumidified air
without dust and dirt.
The under-bench air conditioner is operated with the remote control.
I
NOTE
The under-bench air conditioner can lower the temperature within the
vehicle to a certain level. The temperature depends on the type of
vehicle, the ambient temperature and the cooling capacity of your
under-bench air conditioner.
Below an outer temperature of 16 °C the under-bench air conditioner
doesn’t cool anymore. In this case only use the air conditioning mode
“Circulating air” ( ).
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Technical description
11
6.1 Components
The refrigerant circuit of the under-bench air conditioner consists of the following
main components (fig. 1 , page 2):
Compressor (1)
The compressor draws in the refrigerant used and compresses it. This raises the
pressure and therefore the temperature of the refrigerant.
Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past
absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The
refrigerant absorbs the heat and vaporises.
Blower (4)
A blower distributes the cooled or heated air within the vehicle through an air
outlet unit.
4-way valve (5)
The 4-way valve reverses the cooling circuit. Thus the internal register of the
evaporator becomes a condenser and heats the air passing through.
Electric heating element (6)
The electric heating element increases the heating effect when the outer
temperature is low.
Air inlet (7), air outlet (8) for external heat exchanger
Air is sucked into the device through the air inlet and escapes through the air
outlet.
Air inlet (9), air outlet (10) for internal heat exchanger
Air is sucked into the device through the air inlet and escapes through the air
outlet. The internal heat exchanger treats the air in order to be cold or hot
depending on active mode.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Technical description FreshWell3000
12
6.2 Receiver
The receiver (fig. 2, page 2) contains the following control and display elements:
In case of an alarm the display shows an error code to identify the fault:
No. Explanation
1 Digital display Displays the room temperature.
2 Red/green LED Constantly lit, red: the stand-by mode is active
Constantly lit, green: any other mode is active
Flashing, red/green: the under-bench air conditioner is on,
but the supply voltage is not present
3 Blue LED Constantly lit: the cooling mode is active
Flashing: the dehumidification mode is active
Off: any other mode is active
4 Orange LED Constantly lit: the heating mode is active
Flashing: the heating mode is active, but the air conditioner is
not yet producing hot air, because the defrost function or the
preventing cold air function is active
The defrost function prevents ice on the external battery
exchanger while in heating mode.
The preventing cold air function prevents that cold air is blown
into the vehicle while in heating mode.
Off: any other mode is active
5 Yellow LED Constantly lit: the timer mode is active
Off: the timer mode is not active
Code Explanation
E1 Room temperature probe fault
E2 Indoor battery temperature probe fault
E3 Outdoor battery temperature probe fault
E4 Control card communication fault (control card failure)
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Technical description
13
6.3 Remote control
All settings of the device (e. g. temperature settings, timer programming) are
transmitted to the under-bench air conditioner by remote control.
The following control and display elements are available on the remote control
(fig. 3, page 3) :
No. Explanation
1 Digital display:
Displays the following:
Time
Selected room temperature (target value) in °C or °F
Actual room temperature
Air conditioning mode
Blower level
Symbols for active additional functions
Battery status
2
button:
Switches the air conditioner and remote control on or to stand-by mode
3
button:
Selects the blower setting
4 MODE button:
Selects the air conditioning mode
5
button:
Activates the sleep function. The sleep function automatically modifies the target
value to provide a pleasant sleeping temperature.
6
button:
Press once:
Displays the current interior temperature (symbol is dis-
played).
Press again: Displays the set temperature.
7
button:
No function assigned yet
8 °C/°F button:
Switches between temperature units Celsius (°C) and Fahrenheit (°F).
9
button:
Sets the timer and the clock.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Technical description FreshWell3000
14
6.4 Air conditioning modes
The under-bench air conditioner has the following air conditioning modes:
10 SET button:
Confirms and saves settings.
11
button:
No function assigned yet
12 + button:
Increases the value
13 button:
Reduces the value
14
Symbol (batteries empty)
Is displayed when the batteries in the remote control are empty. If this happens,
replace the batteries, see chapter “Replacing the remote control batteries” on
page 22.
15
Symbol (transmitting values)
Is displayed briefly when the remote control is transmitting values to the under-
bench air conditioner.
Air conditioning
mode
Display
message
Explanation
Automatic In this mode the air conditioner sets the temperature
(set point) automatically and manages the compressor,
heat pump and fan speed by comparing the set point
with the room temperature and it sets the
corresponding conditioning mode (see following
table).
The , + and buttons are deactivated in this mode.
Cooling You specify the temperature and blower settings, and
the air conditioner cools the interior to this tempera-
ture.
Heating You specify the temperature and blower settings, and
the air conditioner heats the interior to this tempera-
ture.
No. Explanation
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Technical description
15
6.5 Additional functions
The under-bench air conditioner has the following additional functions:
Circulating air You specify the blower level, and the air conditioner
blows air into the interior
.
Dehumidification You specify the temperature, and the air conditioner
cools the interior to this temperature and controls the
necessary blower output and dehumidifys the interior
(Circulating air mode).
The button is deactivated in this mode.
Current room
temperature ϑ
ϑ ≤ 20 °C 22 °C < ϑ < 25 °C ϑ 25 °C
Set point: 2C 2C 2C
Conditioning
mode:
Heating or
Circulating air
Dehumidification or
Circulating air
Cooling
Additional
function
Display
message
Explanation
Timer The air conditioner is switched on at the specified
time.
The air conditioner is switched off at the specified
time.
The air conditioner is switched on and off at the
specified times.
Sleep The set temperature is modified by 1 °C after one hour
and by 2 °C after two hours to generate a pleasant
temperature for sleeping.
Air conditioning
mode
Display
message
Explanation
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Before initial use FreshWell3000
16
7 Before initial use
Inspection before starting up
Before you switch on the under-bench air conditioner, observe the following:
Check whether the supply voltage and frequency correspond to the values
specified in the technical data, see page 29.
Ensure both the air intake opening and the air nozzles are free. All ventilation
grilles must always be kept free to ensure that the under-bench air conditioner is
able to operate at maximum capacity.
!
Setting the time
Set the current time: see chapter “Setting the time” on page 23.
Set the remote control
Insert the batteries (see chapter “Replacing the remote control batteries” on
page 22).
The display shows all symbols for 5 seconds.
Press simultaneously the
button and the button during this 5 seconds.
The display shows the default model number.
Press simultaneously + and button within 3 seconds to select the model
number:
FreshWell3000: 02
–FreshJet: 07
–FreshLight: 11
The display shows all symbols for 5 seconds.
The remote control is ready for operation.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Operating the under-bench air conditioner
17
8 Operating the under-bench air
conditioner
8.1 Basic notes on operation
The under-bench air conditioner has three operating modes:
The receiver switches on when it receives pulses from the remote control. The
display shows (flashing) the temperature setting, after 10 seconds the display shows
the room temperature, then it switches off.
You can use the remote control to
switch the under-bench air conditioner to and from stand-by mode.
adjust the settings
select additional functions
8.2 Using the remote control
The remote control must be pointed at the IR receiver (fig. 2 4, page 2) on the
receiver during operation.
When a button is pressed, the value is transmitted directly to the under-bench air
conditioner. The under-bench air conditioner confirms the receipt of data with a high
note.
Switching only the remote control to or from stand-by
In stand-by mode, the remote control display shows only the time.
If the remote control is not pointing to the IR receiver (fig. 2
4, page 2) on the
control panel, you can activate the remote control or switch it to stand-by
independently from the under-bench air conditioner:
Press the button.
Operating mode Features
Stand-by The under-bench air conditioner is ready for operation and can be
switched on with the remote control.
On The under-bench air conditioner is conditioning the air in the interior.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Operating the under-bench air conditioner FreshWell3000
18
8.3 Hint for improved use
The following hints will optimise the performance of your under-bench air
conditioner:
Improve the heat insulation of your vehicle by sealing gaps and hanging reflective
blinds or curtains on your windows.
If the vehicle has been subjected to direct sunlight for a long time: Operate the
under-bench air conditioner in the “Circulating air” ( ) mode with the windows
open for a while before switching on the “Cooling” ( ) air conditioning mode.
Avoid opening doors and windows as far as possible in the “Cooling” ( )
mode.
Select an appropriate temperature and blower speed.
Align the air nozzles sensibly.
Make sure the air nozzles and intake grille are not covered by cloths, paper or
other objects.
Clean the air filter periodically.
8.4 Switching the under-bench air conditioner on and off
I
When you switch on the under-bench air conditioner, the device waits a few minutes
before operating the compressor.
8.5 Selecting the air conditioning mode
I
Select the air conditioning mode of your choice using the MODE key, see
chapter “Air conditioning modes” on page 14.
NOTE
When it is switched on, it begins to condition the air to the values that
were set most recently.
You can use the remote control to switch the under-bench air
conditioner to and from stand-by mode. Press the button.
You can operate the under-bench by remote control and via LIN bus.
If you use LIN bus control the receiver is not required.
Don‘t use the under-bench air conditioner if the vehicle is tilted more
than 10°.
NOTE
The under-bench air conditioner must be switched on.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
FreshWell3000 Operating the under-bench air conditioner
19
The under-bench air conditioner confirms the receipt of the values with a high
note.
The under-bench air conditioner is switched to the selected air conditioning
mode.
8.6 Selecting the blower setting manually
I
The blower controls the strength of the air supply.
In the “Cooling” ( ) and “Circulating air” ( ) modes, the blower levels can be
selected manually. In the other air conditioning modes, the under-bench air
conditioner controls the blower level automatically.
Use the button to select the desired blower level.
The under-bench air conditioner confirms the receipt of the values with a high
note.
The new blower level has been set.
8.7 Setting the temperature
I
NOTE
The under-bench air conditioner must be switched on.
Display message Explanation
Low blower level
Medium blower level
High blower level
not available in the “Cooling” ( ) mode
Automatic mode, only available in the “Cooling” ( ), “Heating”
( ) and “Dehumidifying” ( ) modes.
NOTE
The under-bench air conditioner must be switched on.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
EN
Operating the under-bench air conditioner FreshWell3000
20
Cooling Mode
In the “Cooling” ( ), and “Dehumidifying” ( ) modes, you can specify a
temperature between 16 °C and 31 °C via the remote control.
Use the + or button to select the desired temperature.
The under-bench air conditioner confirms the receipt of the values with a high
note.
The temperature is set on the under-bench air conditioner.
Heating Mode
In the “Heating” ( ) mode, you can specify a temperature between 16 °C and 31 °C
via the remote control.
Use the + or button to select the desired temperature.
The under-bench air conditioner confirms the receipt of the values with a high
note.
The temperature is set on the under-bench air conditioner.
8.8 Setting the timer
The timer function allows you to set a specific time period for air conditioning. You
can specify the switch-on time, the switch-off time or both values.
I
Before programming the timer, select the air conditioning mode and all required
values (e.g. temperature).
Setting the switch-on time
I
Press the button once.
The ON symbol ( ) flashes on the display of the remote control.
Use the + or button to set the time when the under-bench air conditioner is to
switch on.
NOTE
The remote control returns to its initial mode if no button is pressed on
the remote control for 15 seconds while programming the timer.
NOTE
The under-bench air conditioner must be switched off.
)UHVK:HOO2VERRN6HLWH0LWWZRFK'H]HPEHU
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392

Dometic FreshWell FW3000 Návod na používanie

Typ
Návod na používanie
Tento návod je vhodný aj pre