Safety Instructions MCS6, MCS12, MSC16
10
✓ This symbol describes the result of an action.
fig. 1 5, page 3: This refers to an element in an illustration. In this case,
item 5 in figure 1 on page 3.
2 Safety Instructions
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and
excess voltage
Alterations to the product without express permission from the manu-
facturer
Use for purposes other than those described in the operating manual
2.1 General Safety
!
WARNING!
Danger of electrocution!
The units are AC voltage components, running on 230 V~.
Electrical shock hazard!
Disconnect voltage at main panel or power source before opening any
cover.
Failure to comply may result in injury or death.
To minimize the hazard of electrical shock and personal injury, this
component must be effectively grounded.
This system does not meet requirements for ignition protection. Do not
install in spaces containing gasoline engines, tanks, LPG/CPG cylin-
ders, regulators, valves or fuel line fittings.
Failure to comply may result in injury or death.
Do not terminate condensate drain line
– within 1 m of any outlet of engine or generator exhaust systems,
– in a compartment housing of an engine or generator,
– in a bilge, unless the drain is connected properly to a sealed con-
densate or shower sump pump.
Failure to comply may allow bilge or engine room vapors to mix with
the air conditioners return-air and contaminate living areas which
may result in injury or death.
In order to prevent the ingress of carbon monoxide (CO) or other
harmful vapors, a trap should be installed in the condensate drain
line(s).
Installation and servicing of this system can be hazardous due to
system pressure and electrical components.