Waeco 4-Way Manifold, 4-Way-Manifold (R1234YF), Waeco 4-Way-Manifold Návod na používanie

  • Prečítal som si návod na použitie 4-cestného ventilu WAECO pre chladivá R-134a a R-1234yf. Som pripravený odpovedať na vaše otázky týkajúce sa jeho montáže, obsluhy a funkcií. Dokument obsahuje informácie o obsahu balenia, postupe plnenia a diagnostiky klimatizačného systému a ďalšie dôležité detaily.
  • Na aké chladivá je tento 4-cestný ventil určený?
    Aké funkcie tento ventil ponúka?
    Čo všetko je súčasťou balenia?
4-Way Manifold
DE 4 4-Wege-Ventil
Montage- und Bedienungsanleitung
EN 10 4-Way Manifold
Installation and Operating Manual
FR 16 Collecteur 4 voies
Instructions de montage et de service
ES 23 Grupo manométrico de 4 vías
Instrucciones de montaje y de uso
IT 30 Gruppo manometrico a 4 vie
Istruzioni di montaggio e d’uso
NL 37 4-wegmondstuk
Montagehandleiding en gebruiks-
aanwijzing
DA 43 4-vejs manifold
Monterings- og betjeningsvejledning
SV 49 4-veis manifold
Monterings- och bruksanvisning
NO 55 4-veis manifold
Monterings- og bruksanvisning
FI 61 4-tieventtiili
Asennus- ja käyttöohje
PT 67 Coletor de 4 vias
Instruções de montagem e manual de
instruções
RU 74 4-сторонний коллектор
Инструкция по монтажу и
эксплуатации
PL 81 Rozdzielacz 4-przewodowy
Instrukcja montażu i obsługi
CS 88 Čtyřcestný rozdělovač
Návod k montáži a obsluze
SK 94 4-cestný ventil
Návod na montáž a uvedenie do
prevádzky
HU 100 4-utas szervizcsaptelep
Szerelési és használati útmutató
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 1 Mittwoch, 31. Juli 2019 11:15 11
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 2 Mittwoch, 31. Juli 2019 11:15 11
4-Way Manifold
3
1 2 3
4
5
6
8
7
1
2
1
3
2
4
5
67 89
10
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 3 Mittwoch, 31. Juli 2019 11:15 11
DE
Sicherheitshinweise 4-Way Manifold
4
Bitte lesen Sie diese Anleitung vor Einbau und Inbetriebnahme sorg-
fältig durch und bewahren Sie sie auf. Geben Sie sie im Falle einer
Weitergabe des Produktes an den Nutzer weiter.
Inhaltsverzeichnis
1 Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Bestimmungsgemäßer Gebrauch . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Technische Beschreibung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 4-Wege-Ventil bedienen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Gewährleistung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7 Entsorgung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8 Technische Daten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Sicherheitshinweise
Der Hersteller übernimmt in folgenden Fällen keine Haftung für Schäden:
Beschädigungen am Produkt durch mechanische Einflüsse
Veränderungen am Produkt ohne ausdrückliche Genehmigung vom
Hersteller
Verwendung für andere als die in der Anleitung beschriebenen Zwecke
1.1 Allgemeine Sicherheit
!
WARNUNG!
Das Gerät darf ausschließlich durch Personal verwendet wer-
den, das eine geeignete technische Ausbildung nachweisen
kann und die Wirkungsweise und Grundprinzipien von Kühl-
oder Klimaanlagen sowie von Kältemitteln kennt.
Das Gerät darf ausschließlich durch Personal verwendet wer-
den, das über einen gültigen Sachkundenachweiß verfügt.
Benutzen Sie dieses Gerät nur für den angegebenen Verwen-
dungszweck.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 4 Mittwoch, 31. Juli 2019 11:15 11
DE
4-Way Manifold Lieferumfang
5
Die Wartung und Reparatur der Geräts darf nur durch qualifi-
ziertes und autorisiertes Personal von geeigneten und zertifi-
zierten Fachfirmen vorgenommen werden.
1.2 Sicherheit beim Betrieb des Gerätes
!
VORSICHT!
Nehmen Sie das Gerät nicht in Betrieb, wenn es beschädigt ist.
Tragen Sie bei der Arbeit mit der Monteurhilfe Schutzhand-
schuhe und eine Schutzbrille.
Verwenden Sie die Monteurhilfe nur in gut belüfteten Räumen
oder im Freien.
A
ACHTUNG!
Tauchen Sie das Gerät nie in Wasser.
Schützen Sie das Gerät vor Hitze und Nässe.
Verwenden Sie nur das Kältemittel, das für diese Ausführung
freigegeben ist.
2Lieferumfang
Pos. in
Abb. 1,
Seite 3
Menge Erklärung
1 1 Tragekoffer
2 1 Befüllschlauch (1,8 m) (gelb)
3 1 Anschlussschlauch (1,8 m) für den Niederdruck-Anschluss
(blau)
4 1 Anschlussschlauch (1,8 m) für den Hochdruck-Anschluss
(rot)
5 1 Service-Schnellkupplung für den Hochdruck-Anschluss
6 1 Service-Schnellkupplung für den Niederdruck-Anschluss
7 1 Vakuumschlauch (1,8 m), 3/8" SAE (gelb)
8 1 4-Wege-Ventil mit Manometern
1 Montage- und Bedienungsanleitung
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 5 Mittwoch, 31. Juli 2019 11:15 11
DE
Bestimmungsgemäßer Gebrauch 4-Way Manifold
6
3 Bestimmungsgemäßer Gebrauch
Das 4-Wege-Ventil ist ausgelegt zum Prüfen und Befüllen von Fahrzeug-
klimaanlagen.
Das 4-Wege-Ventil ist nur einsetzbar für Klimaanlagen, die mit einem Nieder-
druck-, einem Hochdruck- oder beiden Anschlüssen ausgestattet sind.
Das 4-Wege-Ventil ist in zwei Modellen verfügbar:
für Klimaanlagen mit R-134a (Art.-Nr. 8885100161)
für Klimaanlagen mit R-1234yf (Art.-Nr. 8885100162)
4 Technische Beschreibung
Das 4-Wege-Ventil ist eine Monteurhilfe, die sich eignet, um an Fahrzeug-
klimaanlagen folgende Maßnahmen durch eventuell benötigte Zusatzgeräte
durchzuführen:
Diagnose
Kältemittelrückgewinnung
Evakuieren
Befüllung der Hochdruckseite
Befüllung der Niederdruckseite
4.1 Anschlusselemente
Pos. in
Abb. 2,
Seite 3
Bezeichnung Erklärung
1 Manometer (rot) Druckanzeige für Hochdruckseite
2 Manometer (blau) Druckanzeige für Niederdruckseite
3 Regler „HIGH“ (rot) Öffnet/schließt die Hochdruckseite
4 Regler „LOW“ (blau) Öffnet/schließt die Niederdruckseite
5 Regler „VAC“ (gelb) Evakuiert/belüftet die Klimaanlage
6 Anschluss Anschluss der Niederdruckseite
7 Anschluss 3/4" SAE Anschluss für Vakuumpumpe
8 Anschluss Anschluss für externe Kältemittelflasche
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 6 Mittwoch, 31. Juli 2019 11:15 11
DE
4-Way Manifold 4-Wege-Ventil bedienen
7
5 4-Wege-Ventil bedienen
5.1 Klimaanlage anschließen
Verwenden Sie die Niederdruck-Schnellkupplung (blau) (Abb. 1 6,
Seite 3), um den blauen Schlauch mit dem Niederdruck-Anschluss der
Klimaanlage zu verbinden."
Verwenden Sie die Hochdruck-Schnellkupplung (rot) (Abb. 1 5,
Seite 3), um den roten Schlauch mit dem Hochdruck-Anschluss der Mon-
teurhilfe zu verbinden.
Verbinden Sie den Vakuum-Anschluss (Abb. 2 7, Seite 3) mit dem
gelben, dicken Vakuumschlauch mit einer Vakuumpumpe.
Schließen Sie mit dem gelben, dünnen Befüllschlauch eine externe Kälte-
mittelflasche an (Abb. 2 2, Seite 3).
5.2 Klimaanlage befüllen
Stellen Sie sicher, dass die Klimaanlage leer ist.
Evakuieren Sie nun die Klimaanlage wie folgt:
Öffnen Sie den ReglerVAC (gelb) (Abb. 2 5, Seite 3), um ein Vakuum
zu erzeugen.
Öffnen Sie den Regler „HIGH“ (rot) (Abb. 2 3, Seite 3).
Öffnen Sie den Regler „LOW“ (blau) (Abb. 2 4, Seite 3).
Starten Sie die Vakuumpumpe.
Schließen Sie den Regler „VAC“ (gelb).
Wenn der Evakuierungsprozess abgeschlossen ist, schalten Sie die
Pumpe aus.
9 Anschluss Anschluss der Hochdruckseite
10 Regler „REF“ (grün) Befüllt die Klimaanlage
Pos. in
Abb. 2,
Seite 3
Bezeichnung Erklärung
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 7 Mittwoch, 31. Juli 2019 11:15 11
DE
4-Wege-Ventil bedienen 4-Way Manifold
8
Prüfen Sie die Anlage auf Dichtheit.
Schließen Sie den Regler „HIGH“ (rot).
Schließen Sie den Regler „LOW“ (blau).
Befüllen Sie nun die Klimaanlage wie folgt:
Öffnen Sie je nach Bedarf den Regler „HIGH“ (rot) oder den Regler „LOW“
(blau).
Öffnen Sie den Regler „REF“ (grün) (Abb. 2 10, Seite 3), um über eine
externe Kältemittelflasche Kältemittel zu befüllen, bis die erforderliche
Menge erreicht ist.
5.3 Befüllung beenden
Schließen Sie alle Ventile.
Lösen Sie alle Verbindungen.
Recyclen Sie das Kältemittel aus den Schläuchen.
5.4 Diagnose/Druckprüfung durchführen
Schließen Sie alle Ventile.
Der Druck in der Klimaanlage wird angezeigt.
5.5 Kältemittel rückgewinnen
Öffnen Sie je nach Bedarf den Regler „HIGH“ (rot) oder den Regler „LOW“
(blau).
Öffnen Sie den Regler „REF“ (grün) (Abb. 2 10, Seite 3), um das Kälte-
mittel mithilfe einer Absaugstation aus der Klimaanlage in eine externe
Kältemittelflasche zu füllen.
Schließen Sie alle Ventile.
Wenn die Klimaanlage vollständig entleert ist, ist der angezeigte Druck
0bar (0Pa).
Öffnen Sie bei Bedarf die Regler erneut bis die Klimaanlage vollständig
entleert ist.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 8 Mittwoch, 31. Juli 2019 11:15 11
DE
4-Way Manifold Gewährleistung
9
6 Gewährleistung
Es gilt die gesetzliche Gewährleistungsfrist. Sollte das Produkt defekt sein,
wenden Sie sich bitte an die Niederlassung des Herstellers in Ihrem Land
(siehe Rückseite) oder an Ihren Fachhändler.
Zur Reparatur- bzw. Gewährleistungsbearbeitung müssen Sie folgende
Unterlagen mitschicken:
eine Kopie der Rechnung mit Kaufdatum,
einen Reklamationsgrund oder eine Fehlerbeschreibung.
7 Entsorgung
Geben Sie das Verpackungsmaterial möglichst in den entsprechenden
Recycling-Müll.
M
Wenn Sie das Produkt endgültig außer Betrieb nehmen, infor-
mieren Sie sich bitte beim nächsten Recyclingcenter oder bei
Ihrem Fachhändler über die zutreffenden Entsorgungsvorschriften.
8 Technische Daten
4-Way-Manifold
R-134a
4-Way-Manifold
R-1234yf
Artikel-Nr.: 8885100161 8885100162
Abmessungen (L x B x H): 400 x 400 x 100 mm
Gewicht: 1,5 kg
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 9 Mittwoch, 31. Juli 2019 11:15 11
EN
Safety instructions 4-way manifold
10
Please read this instruction manual carefully before installation and
first use, and store it in a safe place. If you pass on the product to
another person, hand over this instruction manual along with it.
Table of contents
1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Operating the 4-way manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences
Alterations to the product without express permission from the
manufacturer
Use for purposes other than those described in the operating manual
1.1 General safety
!
WARNING!
The device may only be used by personnel who are able to
demonstrate the appropriate technical training and are familiar
with the operation and basic principles of air conditioners and
refrigerants.
The device may only be used by personnel who have a valid
certificate of competence.
Only use the device for its intended purpose.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 10 Mittwoch, 31. Juli 2019 11:15 11
EN
4-way manifold Scope of delivery
11
Maintenance and repairs to the device may only be performed
by qualified and approved personnel from suitable and certified
specialist companies.
1.2 Operating the device safely
!
CAUTION!
Do not operate the device if it has been damaged.
Always wear gloves and goggles when using the manifold.
Only use the manifold in well-ventilated areas or outdoors.
A
NOTICE!
Never immerse the device in water.
Protect the device from heat and moisture.
Use only the refrigerant approved for this version.
2 Scope of delivery
Item in
fig. 1,
page 3
Quantity Explanation
1 1 Carrying case
2 1 Filling hose (1.8 m) (yellow)
3 1 Connecting hose (1.8 m) for low-pressure connection (blue)
4 1 Connecting hose (1.8 m) for high-pressure connection (red)
5 1 Quick service coupling for high-pressure connection
6 1 Quick service coupling for low-pressure connection
7 1 Vacuum hose (1.8 m), 3/8" SAE (yellow)
8 1 4-way manifold with pressure gauges
1 Installation and operating manual
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 11 Mittwoch, 31. Juli 2019 11:15 11
EN
Intended use 4-way manifold
12
3 Intended use
The 4-way manifold is designed for testing and filling of vehicle air
conditioners.
The 4-way manifold can only be used for air conditioners that are equipped
with a low-pressure connection, high-pressure connection or both connec-
tions.
The 4-way manifold is available in two models:
for air conditioners with R-134a (ref. no. 8885100161)
for air conditioners with R-1234yf (ref. no. 8885100162)
4 Technical description
The 4-way manifold is suitable for carrying out the following measures on
vehicle air conditioners by means of any additional equipment required:
Diagnosis
Refrigerant recovery
Evacuation
Filling the high-pressure side
Filling the low-pressure side
4.1 Connections
Item in
fig. 2,
page 3
Description Explanation
1 Pressure gauge (red) Pressure indicator for the high-pressure
side
2 Pressure gauge (blue) Pressure indicator for the low-pressure side
3 “HIGH” knob (red) Opens/closes the high-pressure side
4 “LOW” knob (blue) Opens/closes the low-pressure side
5 “VAC” knob (yellow) Evacuates/fills the air conditioner
6 Connection Connection of the low-pressure side
7 Connection 3/4" SAE Connection for the vacuum pump
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 12 Mittwoch, 31. Juli 2019 11:15 11
EN
4-way manifold Operating the 4-way manifold
13
5 Operating the 4-way manifold
5.1 Connecting an air conditioner
Use the low-pressure quick coupling (blue) (fig. 1 6, page 3) to connect
the blue hose with the low-pressure connection of the air conditioner.
Use the high-pressure quick coupling (red) (fig. 1 5, page 3) to connect
the red hose with the high-pressure connection of the manifold.
Connect the vacuum connection (fig. 2 7, page 3) with the thick, yellow
vacuum hose to a vacuum pump.
Connect an external refrigerant bottle using the thin, yellow filling hose
(fig. 2 2, page 3).
5.2 Filling the air conditioner
Ensure that the air conditioner is empty.
Now evacuate the air conditioner as follows:
Open the “VAC” knob (yellow) (fig. 2 5, page 3) to create a vacuum.
Open the “HIGH” knob (red) (fig. 2 3, page 3).
Open the “LOW” knob (blue) (fig. 2 4, page 3).
Start the vacuum pump.
Close the “VAC” knob (yellow).
When the evacuation process is complete, turn off the pump.
Check the system for leaks.
8 Connection Connection for the external refrigerant
bottle
9 Connection Connection of the high-pressure side
10 “REF” knob (green) Fills the air conditioner
Item in
fig. 2,
page 3
Description Explanation
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 13 Mittwoch, 31. Juli 2019 11:15 11
EN
Operating the 4-way manifold 4-way manifold
14
Close the “HIGH” knob (red).
Close the “LOW” knob (blue).
Now fill the air conditioner as follows:
Open the “HIGH” knob (red) or the “LOW” knob (blue) as needed.
Open the “REF” knob (green) (fig. 2 10, page 3) to fill refrigerant via an
external refrigerant bottle until the required amount has been reached.
5.3 Completing the filling
Close all valves.
Detach all connections.
Recycle the refrigerant from the hoses.
5.4 Performing the diagnosis/pressure test
Close all valves.
The pressure in the air conditioner is displayed.
5.5 Recovering refrigerant
Open the “HIGH” knob (red) or the “LOW” knob (blue) as needed.
Open the “REF” knob (green) (fig. 2 10, page 3) to fill the refrigerant out
of the air conditioner into an external refrigerant bottle with the help of a
suction station.
Close all valves.
If the air conditioner is completely empty, the displayed pressure is 0 bar
(0 Pa).
If necessary, open the knobs again until the air conditioner is completely
emptied.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 14 Mittwoch, 31. Juli 2019 11:15 11
EN
4-way manifold Warranty
15
6Warranty
The statutory warranty period applies. If the product is defective, please
contact the manufacturer's branch in your country (see back page) or your
retailer.
For repair and warranty processing, please include the following documents
when you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
7 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
8 Technical data
4-way manifold
R-134a
4-way manifold
R-1234yf
Reference number: 8885100161 8885100162
Dimensions (L x W x H): 400 x 400 x 100 mm
Weight: 1.5 kg
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 15 Mittwoch, 31. Juli 2019 11:15 11
FR
Consignes de sécurité 4-Way Manifold
16
Veuillez lire attentivement cette notice avant le montage et la mise en
service. Veuillez ensuite la conserver. En cas de passer le produit,
veuillez le transmettre au nouvel acquéreur.
Sommaire
1 Consignes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 Contenu de la livraison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 Usage conforme. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 Description technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5 Utilisation du collecteur 4 voies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7 Mise au rebut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
8 Caractéristiques techniques. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1 Consignes de sécurité
Le fabricant décline toute responsabilité pour des dommages dans les cas
suivants :
des sollicitations mécaniques ayant endommagé le matériel
des modifications apportées au produit sans autorisation explicite de la
part du fabricant
une utilisation différente de celle décrite dans la notice
1.1 Sécurité générale
!
AVERTISSEMENT !
Seul un personnel pouvant prouver avoir suivi une formation
technique adéquate et connaissant le fonctionnement et les
principes de base des systèmes de climatisation et des réfrigé-
rants est habilité à utiliser l’appareil.
L’appareil doit uniquement être utilisé par un personnel déte-
nant un certificat de compétence valide.
Utilisez l’appareil uniquement conformément à l’usage pour
lequel il a été conçu.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 16 Mittwoch, 31. Juli 2019 11:15 11
FR
4-Way Manifold Contenu de la livraison
17
Seul un personnel qualifié et autorisé de sociétés agréées et
certifiées est habilité à effectuer la maintenance et les répara-
tions de l’appareil.
1.2 Consignes de sécurité concernant le fonctionne-
ment de l’appareil
!
ATTENTION !
N’utilisez pas l’appareil s’il est endommagé.
Portez toujours des gants et des lunettes de protection lors de
l’utilisation du collecteur.
Utilisez le collecteur uniquement dans un espace suffisamment
aéré ou à l’air libre.
A
AVIS !
Ne plongez jamais l’appareil dans l’eau.
Tenez l’appareil à l’abri de la chaleur et de l’humidité.
Utilisez uniquement le réfrigérant approuvé pour cette version.
2 Contenu de la livraison
Position dans
fig. 1, page 3
Quantité Description
1 1 Mallette
2 1 Flexible de charge (1,8 m) (jaune)
3 1 Flexible de raccordement (1,8 m) pour le raccord
basse pression (bleu)
4 1 Flexible de raccordement (1,8 m) pour le raccord
haute pression (rouge)
5 1 Couplage de service rapide pour le raccord haute
pression
6 1 Couplage de service rapide pour le raccord basse
pression
7 1 Flexible de vide (1,8 m), 3/8" SAE (jaune)
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 17 Mittwoch, 31. Juli 2019 11:15 11
FR
Usage conforme 4-Way Manifold
18
3 Usage conforme
Le collecteur 4 voies est conçu pour le test et le remplissage des systèmes
de climatisation pour véhicules.
Le collecteur 4 voies doit uniquement être utilisé sur des systèmes de clima-
tisation équipés d’un raccord basse pression, d’un raccord haute pression ou
les deux.
Le collecteur 4 voies est disponibles en deux versions :
pour climatiseurs avec R-134a (n° d’article 8885100161)
pour climatiseurs avec R-1234yf (n° d’article 8885100162)
4 Description technique
Le collecteur 4 voies convient pour exécuter les mesures suivantes sur les
climatiseurs pour véhicules à l’aide des équipements additionnels
nécessaires :
Diagnostic
Récupération de réfrigérant
Évacuation
Remplissage du côté haute pression
Remplissage du côté basse pression
8 1 Collecteur 4 voies avec manomètres
1 Instructions de montage et de service
Position dans
fig. 1, page 3
Quantité Description
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 18 Mittwoch, 31. Juli 2019 11:15 11
FR
4-Way Manifold Utilisation du collecteur 4 voies
19
4.1 Raccordements
5 Utilisation du collecteur 4 voies
5.1 Raccordement du climatiseur
Utilisez le couplage rapide basse pression (bleu) (fig. 1 6, page 3) pour
brancher le flexible bleu sur le raccord basse pression du climatiseur.
Utilisez le couplage rapide haute pression (rouge) (fig. 1 5, page 3) pour
brancher le flexible rouge sur le raccord haute pression du climatiseur.
Branchez le raccord de vide (fig. 2 7, page 3) avec le flexible de vide
jaune épais sur une pompe à vide.
Raccordez une bouteille de réfrigérant externe à l’aide du flexible de rem-
plissage jaune épais (fig. 2 2, page 3).
Position dans
fig. 2, page 3
Description Description
1 Manomètre (rouge) Indicateur de pression coté haute
pression
2 Manomètre (bleu) Indicateur de pression coté basse
pression
3 Bouton « HIGH »
(rouge)
Ouvre/ferme le côté haute pression
4 Bouton « LOW » (bleu) Ouvre/ferme le côté basse pression
5 Bouton « VAC »
(jaune)
Vide/remplit le climatiseur
6 Raccord Raccordement du côté basse pression
7 Raccord 3/4" SAE Raccordement de la pompe à vide
8 Raccord Raccordement de la bouteille de réfri-
gérant externe
9 Raccord Raccordement du côté haute pression
10 Bouton « REF » (vert) Remplit le climatiseur
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 19 Mittwoch, 31. Juli 2019 11:15 11
FR
Utilisation du collecteur 4 voies 4-Way Manifold
20
5.2 Remplissage du climatiseur
Vérifiez que le climatiseur est bien vide.
Maintenant, purgez le climatiseur de la manière suivante :
Ouvrez le bouton « VAC » (jaune) (fig. 2 5, page 3) pour créer un vide.
Ouvrez le bouton « HIGH » (rouge) (fig. 2 3, page 3).
Ouvrez le bouton « LOW » (bleu) (fig. 2 4, page 3).
Démarrez la pompe à vide.
Fermez le bouton « VAC » (jaune).
Au terme de la purge, arrêtez la pompe.
Vérifiez que le système est étanche.
Fermez le bouton « HIGH » (rouge).
Fermez le bouton « LOW » (bleu).
Maintenant, remplissez le climatiseur de la manière suivante :
Ouvrez le bouton « HIGH » (rouge) ou le bouton « LOW » (bleu) selon les
besoins.
Ouvrez le bouton « REF » (vert) (fig. 2 10, page 3) pour faire le plein de
réfrigérant via une bouteille de réfrigérant externe jusqu’à ce que la quan-
tité requise soit atteinte.
5.3 Terminer le remplissage
Fermez toutes les vannes.
Débranchez tous les raccords.
Recyclez le réfrigérant qui se trouve dans les flexibles.
5.4 Exécution du diagnostic/test de pression
Fermez toutes les vannes.
La pression dans le climatiseur est affichée.
AirCon-4-Way-ManifoldR1234YF-EMEA16.book Seite 20 Mittwoch, 31. Juli 2019 11:15 11
/