FJ 1700

Dometic FJ 1700 Používateľská príručka

  • Prečítal som si prevádzkovú príručku pre strešné klimatizačné jednotky Dometic FreshJet 1700, 2000, 2200 a 3200. Som pripravený odpovedať na vaše otázky týkajúce sa ich prevádzky, čistenia, údržby a riešenia problémov. Príručka popisuje rôzne režimy prevádzky, nastavenie teploty a ďalšie funkcie, ako je časovač a režim spánku.
  • Ako zapnem strešnú klimatizáciu?
    Ako nastavím teplotu?
    Čo robiť, ak klimatizácia neustále vypína?
    Ako vyčistím klimatizáciu?
FJ 1700, FJ 2000, FJ 2200, FJ 3200
Air conditioning roof unit
Operating manual. . . . . . . . . . . . . . . . . . . 15
Dachklimaanlage
Bedienungsanleitung . . . . . . . . . . . . . . . . 33
Climatiseur de toit
Notice d’utilisation . . . . . . . . . . . . . . . . . .53
Aire acondicionado de techo
Instrucciones de uso . . . . . . . . . . . . . . . . . 72
Ar condicionado para tejadilho
Manual de instruções . . . . . . . . . . . . . . . . 91
Climatizzatore a tetto
Istruzioni per l’uso. . . . . . . . . . . . . . . . . . 111
Airconditioning voor dakinbouw
Gebruiksaanwijzing . . . . . . . . . . . . . . . . 130
Klimaanlæg til tagmontering
Betjeningsvejledning . . . . . . . . . . . . . . . 149
Takmonterad klimatanläggning
Bruksanvisning . . . . . . . . . . . . . . . . . . . . 167
Takmontert klimaanlegg
Bruksanvisning . . . . . . . . . . . . . . . . . . . . 185
Kattooilmastointilaitteisto
Käyttöohje . . . . . . . . . . . . . . . . . . . . . . . .202
Накрышный кондиционер
Инструкция по эксплуатации . . . . . . . .220
Klimatyzator dachowy
Instrukcja obsługi . . . . . . . . . . . . . . . . . . 239
Strešné klimatizačné zariadenie
Návod na obsluhu . . . . . . . . . . . . . . . . . 258
Střešní klimatizace
Návod k obsluze. . . . . . . . . . . . . . . . . . . 276
Tet ő kl ím a -b ere nd e z és
Használati utasítás . . . . . . . . . . . . . . . . . 294
Krovna klimatizacijska jedinica
Upute za uporabu. . . . . . . . . . . . . . . . . . 313
Klima tavan ünitesi
Kullanma Kılavuzu. . . . . . . . . . . . . . . . . . 331
Strešna klimatska naprava
Navodilo za uporabo . . . . . . . . . . . . . . . 349
Unitate de aer condiţionat pentru
acoperiş
Instrucţiuni de operare. . . . . . . . . . . . . . 368
Покривен модул на климатичната
инсталация
Инструкция за експлоатация . . . . . . . . 388
Kliimaseade katusele
Kasutusjuhend . . . . . . . . . . . . . . . . . . . . 407
Μονάδα κλιματισμού οροφής
Οδηγίες χειρισμού . . . . . . . . . . . . . . . 425
Stogo oro kondicionavimo blokas
Naudojimo vadovas . . . . . . . . . . . . . . . . 446
Gaisa kondicionēšanas jumta
iekārta
Lietošanas rokasgrāmata . . . . . . . . . . . . 464
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
HR
TR
SL
RO
BG
ET
EL
LT
LV
AIR CONDITIONERS
FRESHJET
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 1 Wednesday, January 11, 2023 10:39 AM
© 2023 Dometic Group. The visual appearance of the contents of this manual is protected
by copyright and design law. The underlying technical design and the products contained
herein may be protected by design, patent or be patent pending. The trademarks
mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 2 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
3
FreshJet 1700, 2000, 2200
FreshJet 3200
1
2
4
3
1
2
4
3
1
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 3 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
4
Chillout ADB
ADB
4
3
2
1
1
2
3
4
2
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 4 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
5
1
7
6
13
12
15
14
2
4
311
10
9
5
8
3
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 5 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
6
ADB
Chillout ADB
1
2
15
1
4
3
2
4
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 6 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
7
1
FreshJet 1700, 2000, 2200
1
FreshJet 3200
5
1
1
1
1
FreshJet 1700, 2000, 2200 FreshJet 3200
6
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 7 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
8
1
3
2
AB
ADB
Chillout ADB
1
2
3
AB
7
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 8 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
9
787
254 533
25 – 60
562
535
225
==
480
==
47
25 – 60
257.5 297.5
555
= =
470
225
FreshJet 1700, 2000, 2200 + ADB
FreshJet 1700, 2000, 2200 + Chillout ADB
254 533
787
562
45
8
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 9 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
10
980
703277
248
25 – 60
650
480535
===
470
===
==
555
257.5 297.5
980
703277
650
25 – 60
45
248
FreshJet 3200 + Chillout ADB
FreshJet 3200 + ADB
9
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 10 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
11
FreshJet 1700
0
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 11 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
12
a
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 12 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
13
FreshJet 3200
b
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 13 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200
14
Chillout ADB
c
ADB
d
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 14 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200 Explanation of symbols
EN
15
Original instructions
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product
manual in order to ensure that you install, use, and maintain the product properly at all times. These instructions
MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and
that you understand and agree to abide by the terms and conditions as set forth herein. You agree to use this prod-
uct only for the intended purpose and application and in accordance with the instructions, guidelines, and warn-
ings as set forth in this product manual as well as in accordance with all applicable laws and regulations. A failure to
read and follow the instructions and warnings set forth herein may result in an injury to yourself and others, damage
to your product or damage to other property in the vicinity. This product manual, including the instructions, guide-
lines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date product
information, please visit documents.dometic.com.
You find the installation manual online at:
https://documents.dometic.com/?object_id=73226
The instructions in the installation manual are intended for qualified
personnel in workshops who are familiar with the guidelines and
safety precautions to be applied.
Table of contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
9 Operating the roof air conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
10 Cleaning the roof air conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
11 Maintenance of the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
13 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
14 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1 Explanation of symbols
!WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided, could result in
death or serious injury.
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 15 Wednesday, January 11, 2023 10:39 AM
Safety instructions FJ 1700, FJ 2000, FJ 2200, FJ 3200
EN
16
!
A
I
2 Safety instructions
In particular, the manufacturer will not be liable for any consequential damage, especially consequential damage
caused by failure of the roof air conditioner.
!WARNING! Failure to obey these warnings could result in death or serious
injury.
Electrocution hazard
Do not operate the device if it is visibly damaged.
Always disconnect the power supply when working on the device.
Operate the device only if you are certain that the housing and the cables are undam-
aged.
Health hazard
This device can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowl-
edge if they have been given supervision or instruction concerning use of the device
in a safe way and understand the hazards involved.
Children shall not play with the device.
Installation, maintenance and repairs of the roof air conditioner may only be carried
out by qualified personnel who are familiar with the risks involved when handling
refrigerant and air conditioning systems as well as the relevant regulations. Inade-
quate repairs may cause serious hazards. For repair service, please contact the ser-
vice centre in your country.
Fire hazard / Flammable materials
Keep the ventilation openings free of obstructions.
Do not damage the refrigerant circuit.
Do not use the roof air conditioner near flammable fluids or in closed rooms.
Make sure no combustible objects are stored or installed near the air outlet. A dis-
tance of at least 50 cm must be kept.
•Do
not undo the upper cover of the roof air conditioner in the event of a fire. Use
approved extinguishing agents instead. Do not use water to extinguish fires.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided, could result in
minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 16 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200 Target group for this manual
EN
17
The device shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric
heater).
Do not pierce or burn the device.
Be aware that refrigerants may not contain an odour.
!CAUTION! Failure to obey these cautions could result in minor or moderate
injury.
Health hazard
Only use the device as intended.
Do not make any alterations or conversions to the device.
Do not reach into air outlets or insert any foreign objects in the roof air conditioner.
If faults occur in the roof air conditioner's refrigerant circuit, the roof air conditioner
must be checked by a specialist company and properly repaired. The refrigerant
must never be released into the air.
ANOTICE! Damage hazard
Never drive through automatic car washes when the roof air conditioner is mounted.
Please ask your vehicle manufacturer if a technical inspection is required after fitting
an air conditioner and whether the height entered in your vehicle documents needs
to be altered:
FreshJet1700, 2000, 2200: increased height 225 mm
FreshJet3200: increased height 248 mm
3 Target group for this manual
This operating manual is for the user of the roof air conditioner.
4Scope of delivery
Roof air conditioner
Air outlet unit (Chillout ADB or ADB)
5 Accessories
Available as accessories (not included in scope of delivery):
I
Designation Reference no. FJ1700 FJ2000 FJ2200 FJ3200
DC Kit PP12 9100300003 ––––
DC Kit DSP-T 12 9600007286 ••••
DC Kit DSP-T 24 9600007287 ••••
NOTE
The DC extension kit (accessory) allows the Dometic FreshJet roof air conditioner to be
used while in motion.
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 17 Wednesday, January 11, 2023 10:39 AM
Intended use FJ 1700, FJ 2000, FJ 2200, FJ 3200
EN
18
6 Intended use
The Dometic FreshJet roof air conditioner is designed for use in motorcaravans, caravans and other vehicles with
habitation compartments only. It is not suitable for houses and apartments.
The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar
equipment. It will not work properly if exposed to strong vibrations.
The function of the roof air conditioner is guaranteed for an operating temperature range (see leaflet technical
data).
This product is only suitable for the intended purpose and application in accordance with these instructions.
This manual provides information that is necessary for proper installation and/or operation of the product. Poor
installation and/or improper operating or maintenance will result in unsatisfactory performance and a possible fail-
ure.
The manufacturer accepts no liability for any injury or damage to the product resulting from:
Incorrect assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product specifications.
7 Technical description
The roof air conditioner supplies the interior with cool dehumidified air without dust and dirt.
Dimmable LED lamps integrated in the air outlet unit provide pleasant lighting (LED lights are available only on spe-
cific model).
The roof air conditioner is operated with the remote control.
I
The roof air conditioner is protected against over-voltage. When the supply voltage is above 265 V, the roof air
conditioner stops working. It resumes normal service when the supply voltage is within the allowed range.
7.1 Components
The refrigerant circuit of the roof air conditioner consists of the following main components (fig. 1, page 3):
Compressor (1)
The compressor draws in the refrigerant used and compresses it. This raises the pressure and therefore the tem-
perature of the refrigerant.
Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot
refrigerant gas cools down and becomes liquid.
Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The refrigerant absorbs the heat and
vaporises.
NOTE
The roof air conditioner can lower the temperature within the vehicle to a certain level.
The temperature depends on the type of vehicle, the ambient temperature and the
cooling capacity of your roof air conditioner.
Below an outer temperature of 16 °C the roof air conditioner doesn’t cool anymore. In
this case only use the air conditioning mode “Circulating air” ( ).
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 18 Wednesday, January 11, 2023 10:39 AM
FJ 1700, FJ 2000, FJ 2200, FJ 3200 Technical description
EN
19
Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet unit.
Overview of all parts:
FreshJet1700: fig. 0, page 11
FreshJet2000, 2200 (available for models with heating and soft start): fig. a, page 12
FreshJet3200: fig. b, page 13
Air outlet unit Chillout ADB: fig. c, page 14
Air outlet unit ADB: fig. d, page 14
7.2 Control panel
The control panel is at the air outlet unit of the roof air conditioner (fig. 2, page 4).
It contains the following control and display elements:
No. Explanation
1Status LED
No light: The roof air conditioner is switched off.
Orange light: The roof air conditioner is in stand-by mode.
Green light: The roof air conditioner is switched on.
Flashing green light For models with heat pump only
The roof air conditioning is preparing for heat mode or
defrost is active.
Flashing green/orange: The roof air conditioner is in winter mode.
Red light: Only if the system is connected to 12 Vg: the supply
voltage of 230 Vw is not available.
Continuously flashing red light (----
-):
Over-voltage
The roof air conditioner resumes normal service when
the supply voltage is within the allowed range.
Slowly flashing red light
(---):
Malfunction in interior temperature sensor E1
Medium quickly flashing red light (- -
- - - -):
Malfunction in exterior temperature sensor E2
2 button Switches the roof air conditioner on, off or to stand-by
mode
Pressing the button longer engages the automatic
mode.
3 button Switches the light on or off or dims it.
Only active when the roof air conditioner is switched
on or on stand-by.
4Infrared (IR) receiver for the remote control
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 19 Wednesday, January 11, 2023 10:39 AM
Technical description FJ 1700, FJ 2000, FJ 2200, FJ 3200
EN
20
7.3 Remote control
All settings of the device (e. g. temperature settings, timer programming) are transmitted to the roof air conditioner
by remote control.
The following control and display elements are available on the remote control (fig. 3, page 5) :
No. Explanation
1Display:
Displays the following:
Time
Selected room temperature (target value) in °C or °F
Actual room temperature
Air conditioning mode
Blower level
Symbols for active additional functions
Battery status
2 button:
Switches the air conditioner and remote control on or to stand-by mode
3 button:
Selects the blower setting
4MODE button:
Selects the air conditioning mode
5 button:
Activates the sleep function. The sleep function automatically modifies the target value to provide a
pleasant sleeping temperature.
6 button:
Press once:
Press again:
Displays the current interior temperature
(symbol is displayed).
Displays the set temperature.
7 button:
Activates the “I feel” function. Every 10 minutes, the “I feel” function adjusts the target temperature
to the temperature measured by the remote control.
8°C/°F button:
Switches between temperature units Celsius (°C) and Fahrenheit (°F)
9 button:
Sets the timer and the clock
10 SET button:
Confirms and saves settings
11 button:
Switches the light of the air conditioner on or off and activates the dimming function.
The button remains functional even when the remote control is switched off.
12 + button:
Increases the value
13 button:
Reduces the value
DometicFJ1700-FJ2000-FJ2200-FJ3200_OPM_4445101818_EMEA16_202x-xx-xx.book Page 20 Wednesday, January 11, 2023 10:39 AM
/