Parkside PKO 400 B2 Operation and Safety Notes

Kategória
Vzduchové kompresory
Typ
Operation and Safety Notes
IAN 89566
K
COMPRESSOR
Operation and Safety Notes
Original operating instructions
D
KOMPRESOR
Pokyny pro obsluhu a bezpečnostní pokyny
Originální návod k obsluze
W
KOMPRESOR
Pokyny pre obsluhu a bezpečnostné pokyny
Originálny návod na obsluhu
T
KOMPRESOR
Wskazówki dotyczące obsługi i bezpieczeństwa
Instrukcją oryginalną
e
COMPRESOR
Indicaţii de siguranţă şi de folosire
Instrucţiuni de utilizare originale
F A C
KOMPRESSOR
Bedienungs- und Sicherheitshinweise
Originalbetriebsanleitung
D W
T e
COMPRESSOR PKO 400 B2
Anl_4010164.indb 1Anl_4010164.indb 1 25.03.13 15:5525.03.13 15:55
- 2 -
K
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of
the device.
D
Před čtením si otevřete stranu s obrázky a potom se seznamte se všemi funkcemi přístroje.
W
Pred čítaním si odklopte stranu s obrázkami a potom sa oboznámte so všetkými funkciami prístroja.
T
Przed przeczytaniem proszę rozłożyć stronę z ilustracjami, a następnie proszę zapoznać się z
wszystkimi funkcjami urządzenia.
e
Înainte de a citi instrucţiunile, deschideţi pagina cu fi guri şi apoi familiarizaţi-vă cu toate funcţiile
aparatului.
F A C
Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen Sie sich anschließend mit
allen Funktionen des Gerätes vertraut.
GB Operation and Safety Notes Page 6
CZ Pokyny pro obsluhu a bezpečnostní pokyny Strana 19
SK Pokyny pre obsluhu a bezpečnostné pokyny Strana 32
PL Wskazówki dotyczące obsługi i bezpieczeństwa Strona 45
RO Indicaţii de siguranţă şi de folosire Pagina 60
DE/AT/CH Bedienungs- und Sicherheitshinweise Seite 74
Anl_4010164.indb 2Anl_4010164.indb 2 25.03.13 15:5525.03.13 15:55
- 3 -
1
2
9
11
2
7
8
3
G
3
4
5
6
8
10
13
14
173
1
1515
19
4
20
21
12
16
18
Anl_4010164.indb 3Anl_4010164.indb 3 25.03.13 15:5525.03.13 15:55
- 4 -
4
7 8
6
29 22 23 24 26 8 27 23 2811
25,26
15
28
27
23
5
242311
8
15
29
25
22
B
Anl_4010164.indb 4Anl_4010164.indb 4 25.03.13 15:5525.03.13 15:55
- 5 -
9 10
11 12
A
max
min
15
16
18
16
D F C
15
21
15
Anl_4010164.indb 5Anl_4010164.indb 5 25.03.13 15:5525.03.13 15:55
GB
- 6 -
Table of contents
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
1. Introduction .................................................................................................................................................. 8
2. Safety regulations ....................................................................................................................................... 8
3. Layout and items supplied ........................................................................................................................10
4. Proper use ...................................................................................................................................................11
5. Technical data ............................................................................................................................................11
6. Before starting the equipment .................................................................................................................. 12
7. Assembly and starting .............................................................................................................................. 12
8. Replacing the power cable ...................................................................................................................... 13
9. Cleaning, maintenance, storage, ordering spare parts and transport ................................................. 13
10. Disposal and recycling ............................................................................................................................. 15
11. Possible causes of failure .......................................................................................................................... 16
12. Declaration of conformity .........................................................................................................................17
13. Warranty certifi cate .................................................................................................................................. 18
Anl_4010164.indb 6Anl_4010164.indb 6 25.03.13 15:5625.03.13 15:56
GB
- 7 -
Caution - Read the operating instructions to reduce the risk of inquiry
Wear ear-muffs. The impact of noise can cause damage to hearing.
Beware of electrical voltage!
Beware of hot parts!
Warning! The equipment is remote-controlled and may start-up without warning.
Caution! Before using for the fi rst time, check the oil level and replace the oil sealing plug!
Important! Do not open the stopcock/pressure regulator until the air hose is connected.
If the equipment is overloaded, the overload switch will shut down in order to prevent damage. Once the
equipment has cooled down, activate the button to start up again.
Anl_4010164.indb 7Anl_4010164.indb 7 25.03.13 15:5625.03.13 15:56
GB
- 8 -
1. Introduction
Congratulations on your new purchase.
You have decided in favor of a high-quality pro-
duct. The operating instructions are a part of this
product. They contain information of importance
for your safety, for the use of the product and for
its disposal. Before you use the product, acquaint
yourself with all the information concerning its
operation and safety. Use the product only as
described and only for the listed areas of applica-
tion. If you hand on the product to other people,
give them all the documentation as well.
2. Safet y regulations
Caution!
Read all safety regulations and instruc-
tions.
Any errors made in following the safety regu-
lations and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instruc-
tions in a safe place for future use.
2.1 Safety information
Important! The following basic safety
actions must be taken when using this
compressor in order to protect the user
from electric shocks and the risk of injury
and fi re. Read and follow these instruc-
tions before using the equipment.
Keep your work area tidy
Untidy work areas can result in accidents.
Check the ambient conditions
Do not expose the compressor to rain. Never
use the compressor in damp or wet locations.
There is a risk of electric shock! Provide good
lighting. Do not use the compressor near
flammable liquids or gases. There is a risk of
explosion!
Protect yourself against electric
shocks
Avoid bodily contact with earthed parts, e.g.
pipes, radiators, cookers and refrigerators.
Keep children away!
Do not allow other persons to touch the com-
pressor or cable, keep them away from your
work area.
Keep your compressor in a safe place
When unused, the compressor must be stored
in a dry, locked room out of children’s reach.
Do not overload your compressor
It will run better and safer within its quoted
capacity range.
Wear suitable work clothes
Never wear loose fitting clothes or jewellery.
They may get caught in moving parts. Rubber
gloves and non-slip shoes are recommended
when working outdoors. Wear a hair net if
you have long hair. Risk of injury!
Do not use the cable for purposes
other than that for which it is designed
Do not carry the compressor by its cable and
do not use the cable to pull the plug out of the
socket. Protect the cable from heat, oil and
sharp edges. The cable/plug could become
damaged.
Take care of your compressor
Keep your compressor clean in order to work
well and safely. Follow the maintenance inst-
ructions. Check the power plug and cable on
a regular basis and have them replaced by
an authorized specialist if they are damaged.
Check the extension cable regularly and re-
place it if damaged.
Pull out the power plug
When not in use and before carrying out any
maintenance work.
Avoid unintentional starting
Make sure that the switch is turned off when
connecting to the power supply.
When using an extension cable out-
doors
Check that it is approved for outdoor duty
and is marked accordingly.
Be alert at all times
Watch what you are doing. Use common sen-
se when working. Never use the compressor
when you are distracted.
Check your compressor for damage
Before using the compressor again, carefully
check the safety devices and any slightly da-
Anl_4010164.indb 8Anl_4010164.indb 8 25.03.13 15:5625.03.13 15:56
GB
- 9 -
maged parts to ensure that they are in good
working order. Check that the moving parts
are working correctly, that they do not jam,
and that no parts are damaged. Make sure
that all parts are fitted correctly to ensure that
the equipment remains safe to use. Unless
otherwise stated in the operating instructions,
damaged guards and parts have to be re-
paired or replaced by a customer service
workshop. Damaged switches have to be
replaced by a customer service workshop.
Never use an electric power tool with a switch
that cannot be turned on and off.
Important!
For your own safety you must only use the
accessories and additional units listed in the
operating instructions or recommended or
specified by the manufacturer. The use of
mounted tools or accessories other than those
recommended in the operating instructions
or catalog may place your personal safety
at risk.
Leave all repairs to a qualified electri-
cian
Repairs must be left strictly to qualified electri-
cians or the user might suffer an accident.
Noise
Wear ear muffs when you use the compressor.
Replacing the power cable
To prevent hazards, leave the replacement of
damaged power cables strictly to the manu-
facturer or a qualified electrician. There is a
risk of electric shock!
Inflating tires
Directly after inflating tires, check the pressure
with a suitable pressure gauge, for example
at your filling station.
Roadworthy compressors for building
site operations
Make sure that all lines and fittings are sui-
table for the maximum permissible operating
pressure of the compressor.
Place of installation
Set up the compressor on an even surface.
Make sure that all compressed air lines and
fittings are suitable for the maximum permissi-
ble operating pressure of the compressor.
For pressures above 7 bar it is recommended
to use an air line with a safety cable.
2.2 Safety instructions for working with
compressed air and blasting guns
The compressor pump and lines can become
very hot during operation. Touching these
parts will burn you.
The air which is sucked in by the compressor
must be kept free of impurities that could
cause fires or explosions in the compressor
pump.
When releasing the hose coupling, hold the
hose coupling piece with your hand. This way,
you can protect yourself against injury from
the rebounding hose.
Wear safety goggles when working with the
blow-out pistol. Foreign bodies or blown off
parts can easily cause injuries.
Do not blow at people with the blow-out
pistol and do not clean clothes while being
worn. Risk of injury!
2.3. Safety information for paint spray-
ing
Do not process any paints or solvents with a
flash point below 55° C. There is a risk of ex-
plosion!
Do not heat up paints or solvents. There is a
risk of explosion!
If hazardous liquids are processed, wear pro-
tective filter units (face guards). Also, adhere
to the safety information provided by the ma-
nufacturers of such liquids.
The details and designations of the Ordi-
nance on Hazardous Substances, which
are displayed on the outer packaging of the
processed material, must be observed. Addi-
tional protective measures are to be underta-
ken if necessary, particularly the wearing of
suitable clothing and masks.
Do not smoke during the spraying process
and/or in the work area. There is a risk of ex-
plosion! Paint vapors are easily combustible.
Never set up or operate the equipment in the
vicinity of a fire place, open lights or sparking
machines.
Do not store or eat food and drink in the work
area. Paint vapors are harmful to your health.
Anl_4010164.indb 9Anl_4010164.indb 9 25.03.13 15:5625.03.13 15:56
GB
- 10 -
The work area must exceed 30 m
3
and suf-
ficient ventilation must be ensured during
spraying and drying. Do not spray against the
wind. Always adhere to the regulations of the
local police authority when spraying combus-
tible or hazardous materials.
Do not process media such as white spirit,
butyl alcohol and methylene chloride with the
PVC pressure hose. These media will destroy
the pressure hose.
2.4 Operating pressure vessels
You must keep your pressure vessel in good
working order, operate the vessel correctly,
monitor the vessel, carry out necessary main-
tenance and repair work immediately and
meet the relevant safety precautions.
The supervisory authority may enforce essenti-
al control measures in individual cases.
A pressure vessel is not allowed to be used if
it has faults or deficiencies that can endanger
workers or third parties.
Check the pressure vessel for signs of rust
and damage each time before using. Do not
use the compressor with a damaged or rusty
pressure vessel. If you discover any damage,
then please contact the customer service
workshop.
Do not lose these safety instructions
3. Layout and items supplied
3.1 Layout
1. Transport handle
2. Pressure switch
3. Pressure regulator
4. Quick-lock coupling
(regulated compressed air)
5. Pressure gauge
(for reading the preset pressure)
6. Pressure gauge
(for reading the vessel pressure)
7. Pressure vessel
8. Supporting foot
9. Drain plug for condensed water
10. Axle screw
11. Wheel
12. Non-return valve with discharge line
13. Compressor pump
14. Housing
15. Air lter
16. Oil sealing plug with oil dipstick
17. ON/OFF switch
18. Oil drainage screw
19. Safety valve
20. Quick-lock coupling
(unregulated compressed air)
21. Oil fi ller opening
22. Washer
23. Spring washer
24. Nut
25. Screw
26. Washer
27. Washer
28. Nut
29. Wheel cap
3.2 Items supplied
Open the packaging and take out the equip-
ment with care.
Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until
the end of the guarantee period.
Important!
The equipment and packaging material
are not toys. Do not let children play with
plastic bags, foils or small parts. There is
a danger of swallowing or suffocating!
Anl_4010164.indb 10Anl_4010164.indb 10 25.03.13 15:5625.03.13 15:56
GB
- 11 -
4. Proper use
The compressor is designed to generate com-
pressed air for compressed-air driven tools which
can be driven with an air volume of up to approx.
360 l/min (e.g. a tire infl ator, blow-out pistol and
paint spray gun). Compressed air tools with very
high air consumption have only limited suitability
for use with this compressor. For tools with high air
consumption (e.g. orbital sanders/grinders, rod
grinders, hammer screwdrivers), check whether
the compressor’s air output is suffi cient to operate
the tool in question. The volume of air supplied by
the compressor must be greater than the volume
of air consumed by the compressed air tool at its
operating pressure.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of
any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Mains connection: .........................230 V ~ 50 Hz
Motor rating kW: ................................S1 2400 W
..................................................S2 30 min 2600 W
Compressor speed min
-1
: .............................. 2850
Operating pressure bar: ..............................max. 8
Pressure vessel capacity (in liters): .....................50
Theoretical suction rate l/min.: .........approx. 360
Effective delivery rate at 7 bar: approx. 170 l/min
Sound power level L
WA
in dB: ............................96
K
WA
uncertainty: ...............................................2 dB
Sound pressure level L
pA
in dB: .......................... 74
K
pA
uncertainty: ................................................2 dB
Protection type: ................................................IP20
Weight of the unit in kg: ....................approx. 38.5
Oil (15W 40) ...................................................0.7 l
Load factor:
A load factor of S2 30 min (intermittent periodic
duty) means that you may operate the motor
continuously at its nominal power level (2600
W) for no longer than the time stipulated on the
specifi cations label (30 min). If you fail to observe
this time limit the motor will overheat. During the
OFF period the motor will cool again to its starting
temperature.
The noise emission values were measured in ac-
cordance with EN ISO 2151: 2008.
Anl_4010164.indb 11Anl_4010164.indb 11 25.03.13 15:5625.03.13 15:56
GB
- 12 -
6. Before starting the
equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
Install the compressor near the point of con-
sumption.
Avoid long air lines and supply lines (extensi-
on cables).
Make sure that the intake air is dry and dust-
free.
Do not install the compressor in a damp or
wet room.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
The oil level in the compressor pump has to
be checked before putting the equipment into
operation (see 9.4).
7. Assembly and starting
Important!
You must fully assemble the appliance
before using it for the fi rst time!
You will require the following tools for assembly
and installation:
1 x open-ended wrench size 13 mm (not in-
cluded)
2 x open-ended wrench size 16 mm (not in-
cluded)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting feet (8)
Fit the supplied supporting feet as shown in
Figure 6.
7.3 Fitting the air fi lters (15)
Remove the transportation stopper (B) and screw
the air fi lters (15) securely to the equipment (Fig.
7, 8). Make sure that the intake opening on the air
lter faces down.
7.4 Changing the transportation cover (A)
Remove the transportation cover from the oil fi ller
opening (21) and insert the supplied oil sealing
plug (16) into the oil fi ller opening. (Fig. 9, 10.)
7.5 Mains connection
Before you use the machine, make sure that
the mains voltage is the same as the operating
voltage (see the rating plate).
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossible.
7.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch
on the compressor. To switch off the compressor,
press the ON/OFF switch down.
7.7 Setting the pressure (Fig. 1-3)
Use the pressure regulator (3) to set the pres-
sure on the pressure gauge (5).
Turn the pressure regulator knob to adjust the
pressure.
The set pressure can be drawn from the quick-
lock coupling (4).
The vessel pressure can be read off the pres-
sure gauge (6).
The vessel pressure is drawn from the quick-
lock coupling (20).
Anl_4010164.indb 12Anl_4010164.indb 12 25.03.13 15:5625.03.13 15:56
GB
- 13 -
7.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7.9 Overload cut-out (Fig. 3)
The motor of this equipment is protected against
overload by an overload switch (G). If the rated
current is exceeded, the overload switch (G) will
shut down the equipment. After a short cooling
down period, the equipment can be switched on
again by pressing the overload switch (G).
8. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel to
avoid danger.
9. Cleaning, maintenance,
storage, ordering spare
parts and transport
Important!
Pull out the power plug before doing any
cleaning and maintenance work on the
equipment. Risk of injury from electric
shock!
Important!
Wait until the equipment has cooled
down completely! Risk of burns!
Important!
Always depressurize the equipment be-
fore carrying out any cleaning and main-
tenance work (see 9.7.1)! Risk of injury!
9.1 Cleaning
Keep the equipment free of dirt and dust as
far as possible. Wipe the equipment with a
clean cloth or blow it down with compressed
air at low pressure.
We recommend that you clean the equipment
immediately after you use it.
Clean the equipment regularly with a damp
cloth and some soft soap. Do not use cleaning
agents or solvents; these may be aggressive
to the plastic parts in the equipment. Ensure
that no water can get into the interior of the
equipment.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
9.2 Maintenance work on the pressure
vessel (Figure 1)
Important! To ensure a long service life of the
pressure vessel (7), drain off the condensed water
by opening the drain valve (9) each time after
using. Release the vessel pressure fi rst (see 9.7.1).
Open the drain screw by turning counter-clock-
wise (looking at the screw from the bottom of the
compressor) so that all the condensed water can
run out of the pressure vessel. Then close the drain
screw again (turn it clockwise). Check the pressure
vessel for signs of rust and damage each time
before using. Do not use the compressor with a
damaged or rusty pressure vessel. If you discover
any damage, then please contact the customer
service workshop.
Important!
The condensed water from the pressure
vessel will contain residual oil. Dispose
of the condensed water in an environ-
mentally compatible manner at a suitable
collection point.
Anl_4010164.indb 13Anl_4010164.indb 13 25.03.13 15:5625.03.13 15:56
GB
- 14 -
9.3 Safety valve (Figure 2)
The safety valve (19) has been set for the highest
permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time to
ensure that it works when required. Pull the ring
with suffi cient force until you can hear the com-
pressed air being released. Then release the ring
again.
9.4 Checking the oil level at regular inter-
vals (Figure 11)
Place the compressor on a level and straight
surface. The oil level must be between the two
marks MAX and MIN on the oil dipstick (16). Oil
change: we recommend SAE 15W 40 or equiva-
lent. The original oil fi lling must be changed after
100 hours in operation; thereafter the oil must be
drained and replaced with new oil after every
300 hours in operation.
9.5 Changing the oil (Figure 1,10, 11)
Switch off the motor and pull the mains plug out
of the socket. After releasing any air pressure (see
9.7.1) you can unscrew the oil drain screw (18)
from the compressor pump (13). To prevent the oil
from running out in an uncontrolled manner, hold
a small metal chute under the opening and collect
the oil in a container. If the oil does not drain out
completely, we recommend tilting the compressor
slightly. When the oil has drained out, refi t the oil
drain screw (18).
Dispose of the old oil at a drop-off point
for old oil.
To fi ll in the correct quantity of oil, make sure that
the compressor stands on an even surface. Fill
new oil through the oil fi ller opening (21) until it
comes up to the maximum level. Check the oil
level by inserting the dipstick. Do not exceed
the maximum fi lling quantity. Overfi lling the
equipment may result in damage. Reinsert the oil
sealing plug (16) into the oil fi ller opening (21).
9.6 Cleaning the intake fi lter
(Fig. 2, 3, 12)
The intake fi lters (15) prevent the drawing in
of dust and dirt. It is essential to clean these
lters after at least every 300 hours in opera-
tion. A clogged intake fi lter will decrease the
compressor’s performance dramatically.
Remove the intake fi lters from the equipment by
unscrewing them. The fi lter housing (D) is plugged
on the fi lter cover (C) and can be removed by ap-
plying slight pressure to the fi lter cover. Carefully
tap out the air fi lters (F), the fi lter cover and the
lter housing. Then blow out these parts with com-
pressed air (approx. 3 bar) and reinstall in reverse
order. The fi lter cover and the fi lter housing have
different latching positions. When you assemble
the intake fi lter, make sure that the intake opening
faces down.
9.7 Storage
Important!
Pull out the mains plug and ventilate the
equipment and all connected pneumatic
tools (see 9.7.1). Switch off the compres-
sor and make sure that it is secured in
such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry lo-
cation which is not accessible to unau-
thorized persons. Always store upright,
never tilted! Oil may leak out!
9.7.1 Releasing excess pressure
Release the excess pressure by switching off the
compressor and using the compressed air which
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a
blow-out pistol.
Anl_4010164.indb 14Anl_4010164.indb 14 25.03.13 15:5625.03.13 15:56
GB
- 15 -
9.8 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
For our latest prices and information please go to
www.isc-gmbh.info
9.9 Transport (Figure 1)
Switch off the equipment and pull out the
power plug before lifting and moving the
compressor.
Use the transport handle (1) to move the com-
pressor.
Use the transport handle (1) on the pressure
vessel (7) to lift the compressor. Note the
equipment‘s weight!
Transport the compressor only in an upright
position and secure it against tilting so that no
oil runs out.
Secure the compressor in accordance with the
regulations in force for transporting equipment
in motor vehicles.
10. Disposal and recycling
The unit is supplied in packaging to prevent its
being damaged in transit. This packaging is raw
material and can therefore be reused or can be
returned to the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic. De-
fective components must be disposed of as spe-
cial waste. Ask your dealer or your local council.
For EU countries only
Never place any electric power tools in your
household refuse.
To comply with European Directive 2002/96/EC
concerning old electric and electronic equipment
and its implementation in national laws, old elec-
tric power tools have to be separated from other
waste and disposed of in an environment-friendly
fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the
manufacturer, the owner of the electrical equip-
ment must make sure that the equipment is proper-
ly disposed of if he no longer wants to keep the
equipment. The old equipment can be returned to
a suitable collection point that will dispose of the
equipment in accordance with the national recyc-
ling and waste disposal regulations. This does not
apply to any accessories or aids without electrical
components supplied with the old equipment.
Anl_4010164.indb 15Anl_4010164.indb 15 25.03.13 15:5625.03.13 15:56
GB
- 16 -
11. Possible causes of failure
Problem Cause Solution
The compressor
does not start.
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for condensation
water (9) leaks.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
1. The hose connections have a leak.
2. A quick-lock coupling (4, 20) has
a leak.
3. Insuffi cient pressure set on the pres-
sure regulator (3).
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.
Anl_4010164.indb 16Anl_4010164.indb 16 25.03.13 15:5625.03.13 15:56
GB
- 17 -
12. Declaration of conformity
Yu Feng Quing/Product-ManagementWeichselgartner/General-Manager
D erklärt folgende Konformität gemäß EU-Richtlinie und
Normen für Artikel
GB explains the following conformity according to EU directi-
ves and norms for the following product
F déclare la conformité suivante selon la directive CE et les
normes concernant l’article
I dichiara la seguente conformità secondo la direttiva UE e
le norme per l’articolo
NL verklaart de volgende overeenstemming conform EU
richtlijn en normen voor het product
E declara la siguiente conformidad a tenor de la directiva y
normas de la UE para el artículo
P declara a seguinte conformidade, de acordo com a
directiva CE e normas para o artigo
DK attesterer følgende overensstemmelse i medfør af
EU-direktiv samt standarder for artikel
S förklarar följande överensstämmelse enl. EU-direktiv och
standarder för artikeln
FIN vakuuttaa, että tuote täyttää EU-direktiivin ja standardien
vaatimukset
EE tõendab toote vastavust EL direktiivile ja standarditele
CZ vydává následující prohlášení o shodě podle směrnice EU
a norem pro výrobek
SLO potrjuje sledečo skladnost s smernico EU in standardi za
izdelek
SK vydáva nasledujúce prehlásenie o zhode podľa smernice
EÚ a noriem pre výrobok
H a cikkekhez az EU-irányvonal és Normák szerint a
következő konformitást jelenti ki
PL deklaruje zgodność wymienionego poniżej artykułu z
następującymi normami na podstawie dyrektywy WE.
BG декларира съответното съответствие съгласно
Директива на ЕС и норми за артикул
LV paskaidro šādu atbilstību ES direktīvai un standartiem
LT apibūdina šį atitikimą EU reikalavimams ir prekės normoms
RO declară următoarea conformitate conform directivei UE şi
normelor pentru articolul
GR δηλώνει την ακόλουθη συμμόρφωση σύμφωνα με την
Οδηγία ΕΚ και τα πρότυπα για το προϊόν
HR potvrđuje sljedeću usklađenost prema smjernicama EU i
normama za artikl
Izjava o sukladnosti za ovaj proizvod dostupna je na
internet stranici www.lidl.hr.
BIH potvrđuje sljedeću usklađenost prema smjernicama EU i
normama za artikl
RS potvrđuje sledeću usklađenost prema smernicama EZ i
normama za artikal
RUS следующим удостоверяется, что следующие продукты
соответствуют директивам и нормам ЕС
UKR проголошує про зазначену нижче відповідність виробу
директивам та стандартам ЄС на виріб
MK ја изјавува следната сообрзност согласно
ЕУ-директивата и нормите за артикли
TR Ürünü ile ilgili AB direkti eri ve normları gereğince aşağıda
ıklanan uygunluğu belirtir
N erklærer følgende samsvar i henhold til EU-direktivet og
standarder for artikkel
IS Lýsir uppfyllingu EU-reglna og annarra staðla vöru
Konformitätserklärung
Kompressor PKO 400 B2 (Parkside)
X
87/404/EC_2009/105/EC
2005/32/EC_2009/125/EC
2006/95/EC
2006/28/EC
X
2004/108/EC
2004/22/EC
1999/5/EC
X
97/23/EC
90/396/EC_2009/142/EC
89/686/EC_96/58/EC
X
2011/65/EC
X
2006/42/EC
Annex IV
Noti ed Body:
Noti ed Body No.:
Reg. No.:
2000/14/EC_2005/88/EC
Annex V
Annex VI
Noise measured: L
WA
= dB (A); guaranteed L
WA
= dB (A)
P = KW; L/Ø = cm
Noti ed Body:
2004/26/EC
Emission No.:
Standard references: EN 1012-1; EN 60204-1;
EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-11
Landau/Isar, den 25.03.2013
First CE: 13 Archive-File/Record: NAPR007418
Art.-No.: 40.101.64 I.-No.: 11013 Documents registrar: Siegfried Roider
Subject to change without notice Wiesenweg 22, D-94405 Landau/Isar
Einhell Germany AG · Wiesenweg 22 · D-94405 Landau/Isar
Anl_4010164.indb 17Anl_4010164.indb 17 25.03.13 15:5625.03.13 15:56
GB
13. Warrant y certifi cate
Dear Customer,
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event
that your device develops a fault, please contact our service department at the address shown on this guarantee card.
Of course, if you would prefer to call us then we are also happy to offer our assistance under the service number prin-
ted below. Please note the following terms under which guarantee claims can be made:
1. These guarantee terms cover additional guarantee rights and do not affect your statutory warranty rights. We do
not charge you for this guarantee.
2. Our guarantee only covers problems caused by material or manufacturing defects, and it is restricted to the rec-
tifi cation of these defects or replacement of the device. Please note that our devices have not been designed for
use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment
is used in commercial, trade or industrial applications or for other equivalent activities. The following are also
excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with
the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the
operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use
(such as overloading of the device or use of non-approved tools or accessories), failure to comply with the main-
tenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), effects of
force or external infl uences (e.g. damage caused by the device being dropped) and normal wear resulting from
proper operation of the device. This applies in particular to rechargeable batteries for which we nevertheless
issue a guarantee period of 12 months. The guarantee is rendered null and void if any attempt is made to tamper
with the device.
3. The guarantee is valid for a period of 3 years starting from the purchase date of the device. Guarantee claims
should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No
guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains
applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed
or parts fi tted will not result in an extension of the guarantee period, and no new guarantee will become active
for the work performed or parts fi tted. This also applies when an on-site service is used.
4. In order to assert your guarantee claim, please send your defective device postage-free to the address shown
below. Please enclose either the original or a copy of your sales receipt or another dated proof of purchase.
Please keep your sales receipt in a safe place, as it is your proof of purchase. It would help us if you could de-
scribe the nature of the problem in as much detail as possible. If the defect is covered by our guarantee then your
device will either be repaired immediately and returned to you, or we will send you a new device.
Of course, we are also happy offer a chargeable repair service for any defects which are not covered by the scope
of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device
to our service address.
- 18 -
IAN 89566
Anl_4010164.indb 18Anl_4010164.indb 18 25.03.13 15:5625.03.13 15:56
CZ
- 19 -
Obsah
Patisk nebo jiné rozmnožování dokumentace a průvodních listin, také ve výtažcích, je přípustný pouze s
výslovným souhlasem fi rmy iSC GmbH.
Technické změny vyhrazeny
1. Úvod .......................................................................................................................................................... 21
2. Bezpečnostní pokyny................................................................................................................................ 21
3. Popis přístroje a rozsah dodávky ............................................................................................................23
4. Použití podle účelu určení ........................................................................................................................24
5. Technická data ..........................................................................................................................................24
6. Před uvedením do provozu ......................................................................................................................25
7. Montáž a uvedení do provozu ................................................................................................................25
8. Výměna síťového napájecího vedení ......................................................................................................26
9. Čištění, údržba, uložení, objednání náhradních dílů a transport .........................................................26
10. Likvidace a recyklace ...............................................................................................................................28
11. Možné příčiny výpadku ...........................................................................................................................29
12. Prohlášení o shodě ....................................................................................................................................30
13. Záruční list ................................................................................................................................................. 31
Anl_4010164.indb 19Anl_4010164.indb 19 25.03.13 15:5625.03.13 15:56
CZ
- 20 -
Varování - Ke snížení rizika zranění si přečíst návod k obsluze
Noste ochranu sluchu. Působení hluku může způsobit ztrátu sluchu.
Varování před elektrickým napětím
Varování před horkými díly
Varování! Jednotka je řízena dálkově a může se spustit bez varování
Pozor! ed prvním uvedením do provozu zkontrolovat stav oleje a vyměnit uzavírací zátku oleje!
Pozor! Neotvírat kohoutek/regulátor tlaku dříve, než je napojena vzduchová hadice.
Při přetížení přístroje se vypínač na přetížení vypne, aby se zabránilo škodám. Po ochlazení stlačte
tlačítko, abyste mohli přístroj znovu uvést do provozu.
Anl_4010164.indb 20Anl_4010164.indb 20 25.03.13 15:5625.03.13 15:56
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

Parkside PKO 400 B2 Operation and Safety Notes

Kategória
Vzduchové kompresory
Typ
Operation and Safety Notes

V iných jazykoch