Ottobock 17B46 Návod na používanie

Typ
Návod na používanie
17B46*, 17B71*
Gebrauchsanweisung ................................................................ 3
Instructions for use .................................................................... 8
Instructions d'utilisation ............................................................. 13
Istruzioni per l’uso ..................................................................... 19
Instrucciones de uso ................................................................. 25
Manual de utilização .................................................................. 31
Gebruiksaanwijzing ................................................................... 36
Bruksanvisning ......................................................................... 42
Brugsanvisning ......................................................................... 47
Bruksanvisning ......................................................................... 52
Instrukcja użytkowania ............................................................... 58
Használati utasítás .................................................................... 63
Návod k použití ......................................................................... 69
Kullanma talimatı ....................................................................... 74
Οδηγίες χρήσης ....................................................................... 79
Руководство по применению .................................................... 85
1
2
1 Vorwort Deutsch
INFORMATION
Datum der letzten Aktualisierung: 2021-05-07
Lesen Sie dieses Dokument vor Gebrauch des Produkts aufmerksam
durch und beachten Sie die Sicherheitshinweise.
Weisen Sie den Benutzer in den sicheren Gebrauch des Produkts ein.
Wenden Sie sich an den Hersteller, wenn Sie Fragen zum Produkt ha
ben oder Probleme auftreten.
Melden Sie jedes schwerwiegende Vorkommnis im Zusammenhang
mit dem Produkt, insbesondere eine Verschlechterung des Gesund
heitszustands, dem Hersteller und der zuständigen Behörde Ihres Lan
des.
Bewahren Sie dieses Dokument auf.
Die Gebrauchsanweisung gibt Ihnen wichtige Informationen zur Verarbei
tung der Orthesenkniegelenke 17B46* und 17B71*.
2 Produktbeschreibung
2.1 Verfügbare Größen
Artikelnum
mer
Innen- und Außen
gelenk
Systembreite Material
17B46=16 16mm
17B46=20
außen gerade, innen
gekröpft 20mm
17B71=16 16mm
17B71=20
außen und innen ge
rade 20mm
Edelstahl
2.2 Bauteile/Konstruktion
Lieferumfang (siehe Abb.1)
Pos. Menge
[Stück]
Bezeichnung Artikelkennzeichen
1 1 Gelenkoberteil
2 4 Schrauben 501T7*
3 1 Gelenkmittelteil 6Y19
4 1 Gelenkschraube 501A6=5x5xM5
5 2 Sicherungsschraube 501S22=8xM3.5
7 1 Gelenkunterteil
8 2 Kugellager 509K12
3
Nicht im Lieferumfang enthalten (siehe Abb.1)
Pos. Menge
[Stück]
Bezeichnung Artikelkennzeichen
6 1 Verlängerungsschiene 17B38*, 17B39*, 17B40*,
17B41*, 17B84*
ohne
Abb.
1 Eingussschiene 17Y128*, 17Y129*
3 Bestimmungsgemäße Verwendung
3.1 Verwendungszweck
Das Orthesengelenk ist ausschließlich paarweise zur orthetischen Versor
gung der unteren Extremität bei einem Patienten einzusetzen.
3.2 Indikationen
Bei Teillähmung oder kompletter Lähmung der Beinmuskulatur
Orthopädische Erkrankungen der unteren Extremität
Die Indikation wird vom Arzt gestellt.
3.3 Lebensdauer
Das Produkt ist bei bestimmungsgemäßer Verwendung und fachgerechter
Montage für eine Lebensdauer von 3Jahren ausgelegt.
3.4 Qualifikation
Die Versorgung eines Patienten mit dem Produkt darf nur von ausgebilde
tem Fachpersonal vorgenommen werden. Es wird vorausgesetzt, dass das
Fachpersonal im Umgang mit den unterschiedlichen Techniken, Materialien,
Werkzeugen und Maschinen vertraut ist.
4 Sicherheit
4.1 Bedeutung der Warnsymbolik
VORSICHT Warnung vor möglichen Unfall- und Verletzungsgefahren.
HINWEIS Warnung vor möglichen technischen Schäden.
4.2 Sicherheitshinweise
VORSICHT
Überbeanspruchung tragender Bauteile
Verletzungen durch Funktionsveränderung oder –verlust
Verwenden Sie das Produkt nur für den definierten Einsatzbereich.
4
Falls das Produkt extremen Belastungen ausgesetzt wurde (z.B. durch
Sturz), sorgen Sie für geeignete Maßnahmen (z.B. Reparatur, Aus
tausch, Kontrolle durch den Kundenservice des Herstellers, etc.).
VORSICHT
Fehlerhafter Aufbau oder Montage
Verletzungen durch Funktionsveränderung oder -verlust
Die Montage darf nur von ausgebildetem Fachpersonal durchgeführt
werden.
Beachten Sie die Aufbau- und Montagehinweise.
VORSICHT
Mechanische Beschädigung des Produkts
Verletzungen durch Funktionsveränderung oder –verlust
Arbeiten Sie sorgfältig mit dem Produkt.
Prüfen Sie das Produkt auf Funktion und Gebrauchsfähigkeit.
Verwenden Sie das Produkt bei Funktionsveränderungen oder -verlust
nicht weiter und lassen Sie es durch autorisiertes Fachpersonal kon
trollieren.
VORSICHT
Überbeanspruchung durch Gebrauch an mehr als einem Patienten
Verletzungsgefahr und Funktionsverlust sowie Beschädigungen am Pro
dukt
Verwenden Sie das Produkt nur an einem Patienten.
Beachten Sie die Wartungsempfehlung.
HINWEIS
Thermische Überbelastung des Produkts
Beschädigung durch unsachgemäße thermische Bearbeitung
Führen Sie keine Wärmebehandlung über 300°C durch.
Entfernen Sie vor der thermischen Bearbeitung sämtliche temperatur
kritischen Komponenten (z.B. Kunststoffe).
HINWEIS
Produkt wird falschen Umgebungsbedingungen ausgesetzt
Beschädigungen, Versprödung oder Zerstörung durch unsachgemäße
Handhabung
5
Vermeiden Sie die Lagerung bei kondensierender Umgebungsfeuch
tigkeit.
Vermeiden Sie den Kontakt mit abrasiven Medien (z.B. Sand, Staub).
Setzen Sie das Produkt keinen Temperaturen unter -10°C und über
+60°C aus (z.B. Sauna, übermäßiger Sonneneinstrahlung, Trocknen
auf der Heizung).
INFORMATION
Erhöhter Verschleiß
Die Orthesenkniegelenke nur in Verbindung mit freibeweglichen oder fuß
hebenden Orthesenknöchelgelenken einsetzen. Bei einer Kombination mit
Orthesenknöchelgelenken mit Dorsalanschlag erhöht sich der Verschleiß.
5 Gebrauchsfähigkeit herstellen
INFORMATION
Parallele Ausrichtung der Orthesengelenke
Den Justiersatz 743R6 zur Platzierung der Orthesengelenke am Gipspositiv
verwenden.
Schienen einkleben
Benötigte Materialien: Spezialklebstoff 636W28*, entfettender Reiniger
Aus Stabilitätsgründen ist die Verklebung der Schienen in den Einsteckbe
reichen erforderlich.
1) Die Verbindungsflächen mit einem entfettenden Reiniger reinigen.
2) Den Spezialklebstoff auf die Verbindungsflächen auftragen.
3) Die Schienen einsetzen.
4) Mit den beiliegenden Schrauben fixieren.
5) Mindestens 4Stunden aushärten lassen.
INFORMATION: Die endgültige Festigkeit ist nach 16Stunden er
reicht.
Korrosionsschutz verbessern
Zur Verbesserung des Korrosionsschutzes das Produkt polieren oder sin
tern. Für die Oberflächenbeschichtung empfiehlt Ottobock das Sinterpulver
618T40*.
Zum Oberflächebeschichten das Material nicht länger als 5 Minuten
und bei maximal 150°C erwärmen.
6
Schutzvorrichtung verwenden
Verwenden Sie Gelenkschützer, um das Produkt vor Schmutz zu schüt
zen.
6 Reinigung
Das Produkt nach dem Kontakt mit salz-, chlor- oder seifenhaltigen Wasser
oder bei Verschmutzungen umgehend reinigen.
1) Das Orthesengelenk mit reinem Süßwasser abspülen und vom Schmutz
befreien.
2) Mit einem Tuch abtrocknen oder an der Luft trocknen lassen.
7 Wartung
INFORMATION
Möglicherweise ist das Produkt patientenspezifisch einer erhöhten
Belastung ausgesetzt.
Verkürzen Sie die Wartungsintervalle gemäß den zu erwartenden Be
lastungen.
Der Hersteller schreibt für das Produkt mindestens eine halbjährliche Funkti
ons- und Verschleißkontrolle vor.
Die Ersatzteile sind im Kapitel Produktbeschreibung unter „Bauteile/Kon
struktion“ aufgeführt.
Nur Spezialschmiermittel 633F7 verwenden.
Kugellager auswechseln
HINWEIS
Verkanten des Kugellagers
Mechanische Beschädigung
Das Kugellager beim Einsetzen in das Orthesengelenk nicht verkanten
oder beschädigen.
1) Die Schrauben lösen und das Orthesengelenk demontieren.
2) Das Kugellager aus dem Orthesengelenk entfernen und mit neuem er
setzen.
3) Das Orthesengelenk montieren und die Schrauben anziehen.
4) Zur finalen Montage die Schraubverbindung mit Loctite 241 sichern.
8 Entsorgung
Das Produkt gemäß den geltenden nationalen Vorschriften entsorgen.
7
9 Rechtliche Hinweise
Alle rechtlichen Bedingungen unterliegen dem jeweiligen Landesrecht des
Verwenderlandes und können dementsprechend variieren.
9.1 Haftung
Der Hersteller haftet, wenn das Produkt gemäß den Beschreibungen und
Anweisungen in diesem Dokument verwendet wird. Für Schäden, die durch
Nichtbeachtung dieses Dokuments, insbesondere durch unsachgemäße
Verwendung oder unerlaubte Veränderung des Produkts verursacht werden,
haftet der Hersteller nicht.
9.2 CE-Konformität
Das Produkt erfüllt die Anforderungen der Verordnung (EU) 2017/745 über
Medizinprodukte. Die CE-Konformitätserklärung kann auf der Website des
Herstellers heruntergeladen werden.
1 Foreword English
INFORMATION
Date of last update: 2021-05-07
Please read this document carefully before using the product and
observe the safety notices.
Instruct the user in the safe use of the product.
Please contact the manufacturer if you have questions about the
product or in case of problems.
Report each serious incident related to the product to the manufacturer
and to the relevant authority in your country. This is particularly import
ant when there is a decline in the health state.
Please keep this document for your records.
These instructions for use provide you with important information on the pro
cessing of the 17B46* and 17B71* orthotic knee joints.
2 Product description
2.1 Available sizes
Article num
ber
Medial and lateral
joint
System width Material
17B46=16 16mm
17B46=20
Outside straight,
inside contoured 20mm
Stainless
steel
8
Article num
ber
Medial and lateral
joint
System width Material
17B71=16 16mm
17B71=20
Outside and inside
straight 20mm
Stainless
steel
2.2 Components/design
Scope of delivery (see fig.1)
Item Quantity
[Piece
(s)]
Designation Article number
1 1 Upper joint section
2 4 Screws 501T7*
3 1 Joint centre piece 6Y19
4 1 Joint screw 501A6=5x5xM5
5 2 Lock screw 501S22=8xM3.5
7 1 Lower joint section
8 2 Ball bearing 509K12
Not included in scope of delivery (see fig.1)
Item Quantity
[Piece
(s)]
Designation Article number
6 1 Side bar 17B38*, 17B39*, 17B40*,
17B41*, 17B84*
Not
illus
trated
1 Lamination bar 17Y128*, 17Y129*
3 Intended use
3.1 Indications for use
The orthotic joint is intended exclusively for use as a pair for orthotic fittings
of the lower limbs on one patient.
3.2 Indications
Partial or total paralysis of the leg muscles
Orthopaedic diseases of the lower limbs
Indications must be determined by the physician.
9
3.3 Lifetime
The product is designed for a lifetime of 3years when used as intended and
assembled professionally.
3.4 Qualification
Patients may be fitted with the product only by trained qualified personnel.
The qualified personnel must be familiar with the handling of the various
techniques, materials, machines and tools.
4 Safety
4.1 Explanation of warning symbols
CAUTION Warning regarding possible risks of accident or injury.
NOTICE Warning regarding possible technical damage.
4.2 Safety instructions
CAUTION
Excessive strain on load-bearing components
Injuries due to changes in or loss of functionality
Only use the product for the defined area of application.
If the product has been exposed to extreme strain (e.g.due to falling),
take any necessary measures (e.g.repair, replacement, inspection by
the manufacturer's customer service, etc.).
CAUTION
Incorrect alignment or assembly
Injuries due to changes in or loss of functionality
The product may only be installed by trained, qualified personnel.
Observe the alignment and assembly instructions.
CAUTION
Mechanical damage to the product
Injuries due to changes in or loss of functionality
Use caution when working with the product.
Check the product for proper function and readiness for use.
In case of changes in or loss of functionality, discontinue use of the
product and have it checked by authorised, qualified personnel.
10
CAUTION
Excessive strain due to use on more than one patient
Risk of injury and loss of functionality as well as damage to the product
Use the product on only one patient.
Observe the maintenance recommendations.
NOTICE
Thermal overloading of the product
Damage due to improper thermal treatment
Do not carry out any heat treatment at temperatures above 300°C
(570°F).
Prior to thermal treatment, remove all temperature-critical components
(suchas plastic parts).
NOTICE
Exposure of the product to unsuitable environmental conditions
Damage, brittleness or destruction due to improper handling
Avoid storage in condensing ambient humidity.
Avoid contact with abrasive substances (e.g.sand, dust).
Do not expose the product to temperatures below -10°C (14°F) or
above +60°C (140°F) (e.g.sauna, excessive sunlight, drying on a
radiator).
INFORMATION
Increased wear and tear
The orthotic knee joints are intended only for use in combination with free-
motion or foot lifting orthotic ankle joints. Wear occurs more rapidly in
combinations involving orthotic ankle joints with a dorsal stop.
5 Preparing the product for use
INFORMATION
Parallel alignment of the orthotic joints
Use the 743R6 alignment fixture to position the orthotic joints on the plaster
positive.
11
Gluing in bars
Required materials: 636W28* special adhesive, degreasing cleaner
The bars must be glued in the insertion zones to ensure stability.
1) Clean the connecting surfaces with a degreasing cleaner.
2) Apply the special adhesive to the connecting surfaces.
3) Insert the bars.
4) Secure with the enclosed screws.
5) Allow to cure for at least 4hours.
INFORMATION: Final bonding strength will be reached after
16hours.
Improving corrosion protection
Polish or sinter the product for improved corrosion protection. Ottobock
recommends the 618T40* sintering powder for surface coating.
Do not heat the material longer than 5minutes at max. 150°C for sur
face coating.
Using protective devices
Use joint protectors to protect the product against soiling.
6 Cleaning
Promptly clean the product after contact with water containing salt, chlorine
or soap, or if it gets dirty.
1) Rinse the orthotic joint with clean, fresh water and remove dirt.
2) Dry with a cloth or allow to air dry.
7 Maintenance
INFORMATION
The product may be exposed to increased loads by the patient.
Shorten the maintenance intervals according to the expected loads.
The manufacturer requires at least a semi-annual inspection of the product
to verify functionality and check for wear.
Spare parts are listed in the section "Components/design".
Only use 633F7 special lubricant.
12
Replacing the ball bearing
NOTICE
Canting the ball bearing
Mechanical damage
Do not cant or damage the ball bearing while inserting it into the orthot
ic joint.
1) Loosen the screws and disassemble the orthotic joint.
2) Remove the ball bearing from the orthotic joint and replace it with a new
one.
3) Assemble the orthotic joint and tighten the screws.
4) For the final assembly, secure the screw connection with Loctite241.
8 Disposal
Dispose of the product in accordance with national regulations.
9 Legal information
All legal conditions are subject to the respective national laws of the country
of use and may vary accordingly.
9.1 Liability
The manufacturer will only assume liability if the product is used in accord
ance with the descriptions and instructions provided in this document. The
manufacturer will not assume liability for damage caused by disregarding the
information in this document, particularly due to improper use or unauthor
ised modification of the product.
9.2 CE conformity
The product meets the requirements of Regulation (EU) 2017/745 on medic
al devices. The CE declaration of conformity can be downloaded from the
manufacturer's website.
1 Avant-propos Français
INFORMATION
Date de la dernière mise à jour: 2021-05-07
Veuillez lire attentivement l’intégralité de ce document avant d’utiliser le
produit ainsi que respecter les consignes de sécurité.
Apprenez à l’utilisateur comment utiliser son produit en toute sécurité.
13
Adressez-vous au fabricant si vous avez des questions concernant le
produit ou en cas de problèmes.
Signalez tout incident grave survenu en rapport avec le produit, notam
ment une aggravation de l’état de santé, au fabricant et à l’autorité
compétente de votre pays.
Conservez ce document.
La notice d’utilisation fournit des informations importantes sur la confection
des articulations de genou pour orthèse 17B46* et 17B71*.
2 Description du produit
2.1 Tailles disponibles
Référence Articulations in
terne et externe
Largeur du sys
tème
Matériau
17B46=16 16mm
17B46=20
Externe droite, in
terne coudée 20mm
17B71=16 16mm
17B71=20
Externe et interne
droite 20mm
Acier inoxy
dable
2.2 Construction / éléments constitutifs
Contenu de la livraison (voir ill.1)
Pos. Quantité
[unité]
Désignation Référence
1 1 Partie supérieure de
l’articulation
2 4 Vis 501T7*
3 1 Partie centrale de
l’articulation
6Y19
4 1 Vis d’articulation 501A6=5x5xM5
5 2 Vis de blocage 501S22=8xM3.5
7 1 Partie inférieure de
l’articulation
8 2 Roulement à billes 509K12
Composants non compris dans la livraison (voir ill.1)
Pos. Quantité
[unité]
Désignation Référence
6 1 Rallonge
14
Composants non compris dans la livraison (voir ill.1)
Pos. Quantité
[unité]
Désignation Référence
17B38*, 17B39*, 17B40*,
17B41*, 17B84*
Sans
ill.
1 Ferrure à couler 17Y128*, 17Y129*
3 Utilisation conforme
3.1 Usage prévu
L’articulation d’orthèse doit être utilisée exclusivement par paire pour
l’appareillage orthétique du membre inférieur d’un patient.
3.2 Indications
Paralysie partielle ou complète des muscles de la jambe
Maladies orthopédiques du membre inférieur
L’indication est déterminée par le médecin.
3.3 Durée de vie
Le produit est conçu pour une durée de vie de 3ans si son utilisation est
conforme et le montage correct.
3.4 Qualification
Seul un personnel spécialisé dûment formé est autorisé à appareiller un pa
tient avec le produit. Il est entendu que ces professionnels sont familiarisés
à l’utilisation des diverses méthodes et différents matériaux, outils et ma
chines requis.
4 Sécurité
4.1 Signification des symboles de mise en garde
PRUDENCE Mise en garde contre les éventuels risques d’accidents
et de blessures.
AVIS Mise en garde contre les éventuels dommages tech
niques.
15
4.2 Consignes de sécurité
PRUDENCE
Sollicitation excessive des éléments porteurs
Blessures dues à une modification ou une perte de fonctionnalité
Veuillez utiliser le produit uniquement dans le champ d’application défi
ni.
Si le produit a été soumis à des sollicitations extrêmes (parex. en cas
de chute), prenez les mesures nécessaires (parex. réparation, rempla
cement, contrôle par le service après-vente du fabricant, etc.).
PRUDENCE
Alignement ou montage incorrect
Blessures occasionnées par une modification ou une perte de fonctionnali
Seul le personnel spécialisé et formé à cet effet est autorisé à procéder
au montage.
Respectez les consignes relatives à l’alignement et au montage.
PRUDENCE
Dégradation mécanique du produit
Blessures dues à une modification ou une perte de fonctionnalité
Manipulez le produit avec précaution.
Vérifiez le produit afin de juger s’il est encore fonctionnel.
Cessez d’utiliser le produit en cas de modifications ou de pertes fonc
tionnelles et faites-le contrôler par un personnel spécialisé agréé.
PRUDENCE
Sollicitation excessive due à un usage par plusieurs patients
Risque de blessure et perte de fonctionnalité ainsi que dégradations du
produit
N’utilisez le produit que sur un seul patient.
Respectez les recommandations en matière de maintenance.
AVIS
Surcharge thermique du produit
Dommage provoqué par un traitement thermique non conforme
N’effectuez pas de traitement thermique supérieur à 300°C.
16
Avant de procéder au traitement thermique du produit, éloignez tous
les composants sensibles à la chaleur (telsque les matières plas
tiques).
AVIS
Produit exposé à des conditions d’environnement inappropriées
Détériorations, fragilisation ou destruction dues à une manipulation incor
recte
Évitez de stocker le produit dans un environnement humide avec de la
condensation.
Évitez tout contact avec des éléments abrasifs (p.ex. le sable et la
poussière).
N’exposez pas le produit à des températures inférieures à -10°C ou à
des températures supérieures à +60°C (p.ex. sauna, fort rayonnement
solaire, séchage sur un radiateur).
INFORMATION
Usure accrue
Utilisez les articulations d’orthèses uniquement avec des articulations or
thétiques de cheville mobiles ou relevant le pied. En cas de combinaison
avec des articulations orthétiques de cheville à butée dorsale, l’usure des
composants augmente.
5 Mise en service du produit
INFORMATION
Parallélisme des articulations d’orthèse
Utiliser le kit d’outils de réglage 743R6 pour positionner les articulations
pour orthèse sur le positif en plâtre.
Collage des ferrures
Matériel nécessaire : colle spéciale 636W28*, dégraissant
Pour des raisons de stabilité, il est nécessaire de coller les ferrures dans les
zones d'emboîtement.
1) Nettoyez les surfaces de raccordement à l’aide d’un dégraissant.
2) Appliquez la colle spéciale sur les surfaces de raccordement.
3) Placez les ferrures.
4) Bloquez-les à l’aide des vis fournies.
17
5) Laissez durcir pendant au moins 4heures.
INFORMATION: la résistance définitive est obtenue au bout de
16heures.
Amélioration de la protection anti-corrosion
Polir ou fritter le produit pour en améliorer la protection anti-corrosion.
Ottobock recommande la poudre frittée 618T40* pour le revêtement de sur
face.
Pour le revêtement de surface, ne pas chauffer le matériau plus de 5mi
nutes et à max. 150°C.
Utilisation d’un dispositif de protection
Utiliser des protège-articulations pour protéger le produit contre les sa
lissures.
6 Nettoyage
Après tout contact avec de l’eau salée, chlorée ou savonneuse ou en cas de
salissures, nettoyez immédiatement le produit.
1) Rincer l’articulation pour orthèse avec de l’eau douce pure et la libérer
des souillures.
2) Essuyer avec un chiffon ou la laisser sécher à l’air libre.
7 Maintenance
INFORMATION
Il est possible que le produit soit soumis à une sollicitation accrue
en fonction du patient.
Réduisez les intervalles de maintenance en fonction des sollicitations
prévues.
Le fabricant exige un contrôle, au minimum tous les 6mois, du fonctionne
ment et de l’usure des articulations.
Les pièces de rechange sont indiquées dans le chapitre «Description du
produit», sous le point «Composants/Construction».
Utilisez uniquement le lubrifiant spécial 633F7.
Remplacement du roulement à billes
AVIS
Coincement du roulement à billes
Dégradation mécanique
Ne pas coincer ni endommager le roulement à billes lors de son inser
tion dans l’articulation pour orthèse.
18
1) Desserrer les vis et démonter l’articulation pour orthèse.
2) Retirer le roulement à billes de l’articulation pour orthèse et le remplacer
par un roulement à billes neuf.
3) Monter l’articulation pour orthèse et serrer les vis.
4) Pour le montage final, bloquer le raccord vissé avec du frein-filet Loc
tite241.
8 Mise au rebut
Éliminez le produit conformément aux prescriptions nationales en vigueur.
9 Informations légales
Toutes les conditions légales sont soumises à la législation nationale du
pays d’utilisation concerné et peuvent donc présenter des variations en
conséquence.
9.1 Responsabilité
Le fabricant est responsable si le produit est utilisé conformément aux des
criptions et instructions de ce document. Le fabricant décline toute respon
sabilité pour les dommages découlant d’un non-respect de ce document,
notamment d’une utilisation non conforme ou d’une modification non autori
sée du produit.
9.2 Conformité CE
Ce produit répond aux exigences du Règlement (UE) 2017/745 relatif aux
dispositifs médicaux. La déclaration de conformité CE peut être téléchargée
sur le site Internet du fabricant.
1 Introduzione Italiano
INFORMAZIONE
Data dell'ultimo aggiornamento: 2021-05-07
Leggere attentamente il presente documento prima di utilizzare il pro
dotto e osservare le indicazioni per la sicurezza.
Istruire l'utente sull'utilizzo sicuro del prodotto.
Rivolgersi al fabbricante in caso di domande sul prodotto o all'insorge
re di problemi.
Segnalare al fabbricante e alle autorità competenti del proprio paese
qualsiasi incidente grave in connessione con il prodotto, in particolare
ogni tipo di deterioramento delle condizioni di salute.
Conservare il presente documento.
19
Le istruzioni per l'uso contengono informazioni importanti per la preparazio
ne delle articolazioni di ginocchio per ortesi 17B46* e 17B71*.
2 Descrizione del prodotto
2.1 Misure disponibili
Codice arti
colo
Articolazione inter
na ed esterna
Larghezza del si
stema
Materiale
17B46=16 16mm
17B46=20
esterna diritta, inter
na piegata 20mm
17B71=16 16mm
17B71=20
interna ed esterna di
ritte 20mm
Acciaio inox
2.2 Componenti/costruzione
Fornitura (v. fig.1)
Pos. Quantità
[pezzo]
Denominazione Codice articolo
1 1 Parte superiore articola
zione
2 4 Viti 501T7*
3 1 Parte centrale articola
zione
6Y19
4 1 Vite articolazione 501A6=5x5xM5
5 2 Vite autobloccante 501S22=8xM3.5
7 1 Parte inferiore articola
zione
8 2 Cuscinetto a sfere 509K12
Non in dotazione (v. fig.1)
Pos. Quantità
[pezzo]
Denominazione Codice articolo
6 1 Asta di prolungamento 17B38*, 17B39*, 17B40*,
17B41*, 17B84*
senza
fig.
1 Asta di laminazione 17Y128*, 17Y129*
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Ottobock 17B46 Návod na používanie

Typ
Návod na používanie