RIDGID micro IR-200 Používateľská príručka

Typ
Používateľská príručka
P. 1
P. 13
P. 27
P. 41
P. 55
P. 69
P. 83
P. 97
P. 111
P. 125
P. 139
P. 153
P. 167
P. 181
P. 195
P. 209
P. 223
P. 237
P. 251
P. 265
P. 279
P. 293
P. 307
EN
FR
ES
DE
NL
IT
PT
SV
DA
NO
FI
PL
CZ
SK
RO
HU
EL
HR
SL
SR
RU
TR
KK
RIDGE TOOL COMPANY
micro
IR-200
Tools For The Professional
TM
micro IR-200 Non-Contact Infrared Thermometer
II
Menu Button Use ..................................................................11
High Alarm ............................................................................11
Low Alarm .............................................................................11
Temperature Display Units-C/F .............................................11
Emissivity ..............................................................................11
Cleaning...................................................................................11
Storage ....................................................................................11
Service and Repair .................................................................12
Disposal ..................................................................................12
Battery Disposal .....................................................................12
Lifetime Warranty .....................................................Back Cover
*Original Instructions - English
Table of Contents
Recording Form for Machine Serial Number .........................1
Safety Symbols.........................................................................2
General Safety Rules
Work Area Safety....................................................................3
Electrical Safety......................................................................3
Personal Safety.......................................................................3
Equipment Use and Care .......................................................3
Service....................................................................................4
Spe
cific Safety Information
Infr
ared Thermometer Safety..................................................4
Description, Specifications and Standard Equipment
Description..............................................................................4
Specifications .........................................................................4
Parts .......................................................................................6
LCD Display Icons ..................................................................6
Standard Equipment ...............................................................6
Laser Classification .................................................................7
FCC Statement..........................................................................7
Electromagnetic Compatibility (EMC) ....................................7
Changing/Installing Batteries..................................................7
Pre-Operation Inspection.........................................................8
Set-Up and Operation
Set-Up ....................................................................................9
Operation
Turning ON and OFF (Taking Measurements)......................10
micro IR-200 Controls
Continuous Measurement (Scanning) Mode ........................10
Laser Enabled/Disabled........................................................10
Backlight ...............................................................................11
micro IR-200
Non-Contact Infrared Thermometer
micro IR-200 Non-Contact Infrared Thermometer
Record Serial Number below and retain product serial number which is located on nameplate.
Serial
No.
micro IR-200
WARNING!
Read this Operators Man -
ual carefully before using
this tool. Failure to under-
stand and follow the con-
tents of this manual may
result in electrical shock,
fire and/or serious person -
al injury.
micro IR-200 Non-Contact Infrared Thermometer
2
Safety Symbols
In this operator’s manual and on the product, safety symbols and signal words are used to communicate important safety information. This
section is provided to improve understanding of these signal words and symbols.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE indicates information that relates to the protection of property.
This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important in-
formation on the safe and proper operation of the equipment.
NOTICE
DANGER
WARNING
CAUTION
This symbol means this device contains a Class 2 Laser.
This symbol means do not stare into the laser beam.
This symbol warns of the presence and hazard of a laser beam.
DO NOT STARE INTO BEAM
LASER RADIATION
MAXIMUM OUTPUT < 1mW
WAVELENGTH 630-670nm
CLASS 2 LASER PRODUCT
EN 60825-1:1994/A11:1996/A2:2001/A1:2002
CAUTION
micro IR-200 Non-Contact Infrared Thermometer
3
shoes, hard hat, or hearing protection used for appropriate con-
ditions will reduce personal injuries.
Do not overreach. Keep proper footing and balance at all
times. This enables better control of the power tool in unexpected
situations.
Equipment Use and Care
Do not force equipment. Use the correct equipment for your
application. The correct equipment will do the job better and
safer at the rate for which it is designed.
Do not use equipment if the switch does not turn it ON and
OFF. Any tool that cannot be controlled with the switch is dan-
gerous and must be repaired.
Disconnect the batteries from the equipment before making
an
y adjustments, changing accessories, or storing. Such
preventive safety measures reduce the risk of injury.
Store idle equipment out of the reach of children and do not
allo
w persons unfamiliar with the equipment or these in-
s
tructions to operate the equipment. Equipment can be dan-
gerous in the hands of untrained users.
Maintain equipment. Check for misalignment or binding of mov-
ing parts, missing parts, breakage of parts and any other condi-
tion that may affect the equipment’s operation. If damaged, have
the equipment repaired before use. Many accidents are caused
by
poorly maintained equipment.
Use
the equipment and accessories in accordance with
these instructions, taking into account the working condi-
tions and the work to be performed. Use of the equipment for
operations different from those intended could result in a haz-
ardous situation.
Use only accessories that are recommended by the manu-
facturer for your equipment. Accessories that may be suitable
General Safety Rules
WARNING
Read all safety warnings and in struc tions. Failure to follow the
warn ings and instructions may result in electric shock, fire
and/or serious injury.
SAVE THESE INSTRUCTIONS!
Work Area Safety
Keep your work area clean and well lit. Cluttered or dark areas
invite accidents.
Do not operate equipment in explosive atmospheres, such
as in the presence of flammable liquids, gases or dust. E -
quip ment can create sparks which may ignite the dust or fumes.
Keep children and by-standers a way while operating equip-
ment. Distrac tions can cause you to lose co
ntrol.
Electrical Safety
Avoid body contact with earthed or grounded surfaces such
as pipes, radiators, ranges and refrigerators. There is an in -
creased risk of electrical shock if your body is earthed or
grounded.
Do not expose equipment to rain or wet conditions. Water
en tering equipment will increase the risk of electrical shock.
Personal Safety
Stay alert, watch what you are doing and use common sense
when operating equipment. Do not use equipment while you
are tired or under the influence of drugs, alcohol or medica-
tion. A moment of inattention while operating equipment may re-
sult in serious personal injury.
Use personal protective equipment. Always wear eye protec-
tion. Protective equipment such as dust mask, non-skid safety
micro IR-200 Non-Contact Infrared Thermometer
4
If you have any question concerning this Ridge Tool product:
Contact your local RIDGID distributor.
Visit www.RIDGID.com to find your local Ridge Tool contact point.
Contact Ridge Tool Technical Service Department at rtctechser-
vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
Description, Specifications
And Standard Equipment
Description
The RIDGID
®
micro IR-200 Non-Contact Infrared Thermometer pro-
vides simple, quick, and accurate surface temperature readings at
the push of a button. You simply squeeze the trigger and point the
ultra-sharp dual class II lasers at the surface being measured. The
micro IR-200 provides an immediate temperature measurement on
a clear, easy-to-read backlit LCD display. In addition to numerous
other uses, this rugged, compact instrument enables profe
ssional
tradesman to diagnose heating and ventilation problems, perform
preventative monitoring of electrical motors and systems, trou-
bleshoot steam traps and quickly check fuses or circuit breakers for
overheating without contact.
The micro IR-200 uses optics to sense emitted, reflected and trans-
mitted energy, which is collected and focused onto a detector. The
unit’s electronics translate the information into a temperature read-
ing, which is displayed. Lasers are used to assist in aiming.
Specifications
Temperature Range ......................-58°F to 2192°F
(-50°C to 1200°C)
Distance To Spot Ratio .................30 to 1
for one piece of equipment may become hazardous when used
with other equipment.
Keep handles dry and clean; free from oil and grease. Allows
for better control of the equipment.
Service
Have your equipment serviced by a qualified repair person
using on ly identical replacement parts. This will ensure that
the safety of the tool is maintained.
Specific Safety Information
WARNING
This section contains important safety information that is
specific to this tool.
Read these precautions carefully before using the RIDGID
®
micro IR-200 Non-Contact Infrared Thermometer to reduce the
risk of eye injury or other serious personal injury.
SAVE THESE INSTRUCTIONS!
Keep this manual with the tool for use by the operator.
Infrared Thermometer Safety
Do not look into the laser beam. Looking into the laser beam
may be hazardous to the eyes. Do not look at the laser beam with
optical aids (such as binoculars or telescopes).
Do not direct the laser beam towards other people. Make
sure the laser is aimed above or below eye level. Laser beams
may be
hazardous to the eyes.
Take appropriate precautions when working near electrical,
moving or hot parts. Close contact may cause electrical shock,
entanglement, burns and other serious injury. Protective equip-
ment may be required.
Measuring Accuracy .....................-58°F ~68°F (-50°C ~20°C) :
±4.5°F (2.5°C)
68°F ~1472°F (20°C ~800°C)
±1.0% or ±1.8°F (1.0°C)
Repeatability...................................-58°F ~68°F (-50°C ~20°C) :
±2.3°F (1.3°C)
68°F ~1472°F (20°C ~800°C)
±0.5% or ±0.9°F (0.5°C)
Response Time ..............................150ms
Spectral Response.........................8~14um
Emissivity .......................................Adjustable, 0.10 - 1.00
Over Range Indication ...................LCD will show “----”
Diode Laser ..................................Output <1mW, Wavelength
630~670nm, Class 2 Laser
Product
Temperature Display .....................Current Temperature, MAX
T
emperature
Measuring Units............................Fahrenheit, Celsius
Operating Temperature .................32°F to 122°F (0°C to 50°C)
Storage Temperature ....................14°F to 140°F (-10°C to 60°C)
Display Resolution ..........................0.1°F (0.1°C)
Relative Humidity..........................10%~90% RH Operating,
<80% RH Storage
Batteries........................................ 9V Battery (1), NEDA 1604A
or IEC 6LR61, or Equivalent
IP Rating.......................................IP54
Weight...........................................0.6 lbs (0.3 kg)
micro IR-200 Non-Contact Infrared Thermometer
5
Backlight LCD Display
Trigger Lock
Set High and Low Alarms
Adjustable Emissivity
Figure 1 – micro IR-200 Non-Contact Infrared Thermometer
Features
Rapid Detection Function
Dual Class II Laser Sighting
Automatic Data Hold
MAX Temperature Displays
Precise Non-Contact Measurements
Automatic Selection Range and Display Resolution 0.1°F (0.1°C)
micro IR-200 Non-Contact Infrared Thermometer
6
Standard Equipment
micro IR-200
Carrying Case
Current
Temperature
Value
Lock
Low
Battery
High Alarm
Low Alarm
Celsius/ -
Fahrenheit
Temperature
Units
Maximum
Temperature
Value
Data Hold
Emissivity
Value
Figure 3 – micro IR-200 Display Icons
LCD Display Icons
Laser Enable
Battery 1 x 9V
Operator's Manual
Battery
Compartment
Handle Grip
Trigger
Menu Button
Up Button/ Laser Enable
LCD Display
Down Button/ -
Backlight
Figure 2 – micro IR-200 Parts
Parts
Trigger
Infrared Sensor
Laser
Laser
micro IR-200 Non-Contact Infrared Thermometer
7
Electromagnetic Compatibility (EMC)
The term electromagnetic compatibility is taken to mean the capa-
bility of the product to function smoothly in an environment where
electromagnetic radiation and electrostatic discharges are present
and without causing electromagnet interference to other equipment.
The RIDGID micro IR-200 conforms to all applicable
EMC standards. However, the possibility of it causing interference in
other devices cannot be precluded.
Figure 4 – Removing Battery Compartment
Changing/Installing Batteries
The micro IR-200 is supplied without a battery installed. If the bat-
tery indicator (Figure 3) displays , the battery needs to be re-
placed. Remove the battery prior to long term storage to avoid
battery leakage.
1. Squeeze the battery clips and remove battery compartment
from the thermometer (See Figure 4). If needed, remove bat-
tery.
This equipment is used to make temperature measure-
ments. Incorrect use or improper application may result in incorrect
or inaccurate measurements. Selection of appropriate measure-
ment methods for the conditions is the responsibility of the user.
Laser Classification
The RIDGID micro IR-200 generates a visible laser beam
that is emitted from the front of the device.
The device complies with class 2 lasers according to: EN 60825-
1:1994/A11:1996/A2:2001/A1:2002
FCC Statement
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instru
c-
tions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or tele-
vision reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the
i
nterference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for
help.
NOTICE
NOTICE
2. Install 9V alkaline battery (6LR61), observing the correct polar-
ity as indicated on the battery compartment.
Figure 5 – Battery Holder and Polarity Marking
3. Squeeze the clips and firmly insert into thermometer. The
holder will only go in one way. Do not force. Confirm securely at-
tached.
Pre-Operation Inspection
WARNING
Before each use, inspect your infrared thermometer and cor-
rect any problems to reduce the risk of injury or incorrect
measurements.
Do not look into the laser beam. Looking into the laser beam
may be hazardous to the eyes.
1. Clean any oil, grease or dirt from equipment. This aids inspec-
tion.
2. Inspect the micro IR-200 for any broken, worn, missing, mis-
aligned or binding parts, or any other condition which may pre-
vent safe and normal operation.
micro IR-200 Non-Contact Infrared Thermometer
8
3. Check that the warning labels are present, firmly attached and
readable. (See Figure 6.)
4. If any issues are found during the inspection, do not use the in-
frared thermometer until it has been properly serviced.
5. Following the Operation Instructions, turn the infrared ther-
mometer ON, make a measurement and confirm the same
measurement with another instrument (contact thermometer,
etc.). If the correlation be tween the measurements is not ac-
ceptable, do not use the infrared thermometer until it has been
properly serviced.
Figure 6 – Warning Labels
Set-Up and Operation
WARNING
Do not look into the laser beam. Looking into the laser beam
may be hazardous to the eyes. Do not look at the laser beam
with optical aids (such as binoculars or telescopes).
micro IR-200 Non-Contact Infrared Thermometer
9
Figure 7 – Field Of View
The spot should always be smaller than the surface. The smaller
the surface, the closer the micro IR-200 should be to the sur-
face. For the best accuracy, the surface should be twice as large
as the spot.
Emissivity Emissivity is a term use to describe energy emit-
ting characteristics of materials and has a value ranging from 0
to 1. The micro IR-200 allows adjustment of the emissivity value
from 0.10 to 1.00 to calculate temperatures. If the emissive prop-
erty of a surface is unknown, an emissivity of 0.95 can be ap-
propriate for many applications, such as painted surfaces.
Values of emissivity for common materi
als are included in Fig-
ure 8.
Figure 8 – Emissivity Values of Common Materials
Do not direct the laser beam towards other people. Make sure
the laser is aimed abo
ve or below eye level. Laser beams may
be hazardous to the eyes.
Take appropriate precautions when working near electrical,
moving or hot parts. Close contact may cause electrical shock,
entanglement, burns and other serious injury. Protective equip-
ment may be required.
Set
up and operate the infrared thermometer according to
these procedures to reduce the risk of injury or incorrect meas-
urements.
Set-Up
1. Check for an appropriate work area as indicated in the General
Safety Section.
2. Inspect the object being measured to and confirm that you have
correct equipment for the application. See the Specifications
section for range, accuracy and other information.
There are a variety of factors that can affect the accuracy of the
micro IR-200, including:
Field of view – The micro IR-200 uses two lasers to pro
ject
points on either side of the area to be measured. These points
indicate the approximate diameter of the area (the “Spot”) that
the
temperature is being measured in. As the micro IR-200
moves further (D) away from the surface, that area and spot
size (S) increases. The area is approximately
1
/
30
times the dis-
tance to the surface. (See Figure 7.)
Surface
Material Emissivity
Aluminum, polished 0.05
Asphalt 0.88
Brick 0.90
Concrete, rough 0.91
Copper, polished 0.04
Glass 0.95
Limestone 0.92
Marble, polished 0.90
Material Emissivity
Paint 0.95
Paper, white 0.90
Plaster, rough 0.89
Rubber 0.93
Steel, galvanized 0.28
Steel, oxidized 0.88
Water 0.96
micro IR-200 Non-Contact Infrared Thermometer
10
micro IR-200 Controls
Figure 8 – micro IR-200 Display/Buttons
Continuous Measurement (Scanning) Mode
The micro IR-200 can be locked ON to allow measurements with-
out holding the trigger. Make sure that the unit is pointed in a safe
direction away from any bystanders before turning ON. Turn the
micro IR-200 ON by squeezing and holding the trigger. While hold-
ing the trigger, press and release the menu button. The SCAN and
Lock icons will be ON. Release the trigger, and the micro IR-200
will continuously update the measured temperature until the trigger
switch is squeezed and released again.
Laser Enabled/Disabled
If needed, the lasers used for aiming can be turned off to help con-
serve battery life. If this is done, extra care must be used when aim-
Temperature While the micro IR-200 compensates for vari-
ation from ambient temperature, large changes in ambient and
measured temperatures can reduce accuracy. When significant
changes in ambient temperature (more than 30°F or 17°C) are
encountered, allow fifteen minutes for the micro IR-200 to ad-
just for best accuracy.
Obstructions Steam, dust, smoke and other obstructions
like glass or plastic between the micro IR-200 and the surface
being measured
can decrease accuracy. These obstruct the
unit optics or give false readings (measure the temperature of
the glass instead of the surface). Do not use when obstructions
are present.
3. Make sure that all equipment has been properly inspected.
Operation
Turning ON and OFF (Taking Measurements)
1. Hold the micro IR-200 by the handle grip and point it at the
surface to be measured. Keep away from any electrical, mov-
i
ng or hot parts. Make sure that the unit is pointed in a safe di-
rection away from any bystanders before turning ON.
2. Squeeze the trigger to turn the micro IR-200 ON. When the trig-
ger is squeezed, the SCAN icon will be ON, and the micro IR-
200 will continuously update the displayed current temperature
value and display the maximum temperature value since the
unit was turned ON.
The micro IR-200 can be moved slowly over the surface to lo-
cate hot or cool areas. See the High Alarm and Low Alarm sec-
tions for information on high and low alarm settings.
3. When the trigger is released, the HOLD icon will be ON. The
micro IR-200 will automatically turn OFF after seven seconds
unless the unit is in Continuous Measurement mode.
Menu Button
Trigger
LCD Display
Down Button/ -
Backlight
Laser
micro IR-200 Non-Contact Infrared Thermometer
11
value line. Press and release the menu button again. The Low Alarm
icon will continue to flash, and the Low Alarm temperature will ap-
pear. Use the up/down buttons to change the Low Alarm tempera-
ture as desired. Squeeze the trigger to exit the Settings mode and
save your selection.
Temperature Display Units - °C/°F
The micro IR-200 can display temperatures in either degrees Celsius
(C) or Fahrenheit (F). To change the display unit, squeeze and re-
lease the tri
gger, and then press and release the menu button until
the temperature unit on the screen is flashing. Use the up/down but-
tons to switch between F or C as desired. Squeeze the trigger to exit
the Settings mode and save your selection.
Emissivity
The emissivity value can be set from 0.10 to 1.00. See the Set-Up
section to determine an appropriate value for your application. To ad-
just this value, squeeze and release the trigger, and then press and
release the menu button until the emissivity
value on the screen is
flashing. Use the up/down buttons to increase or decrease the emis-
sivity value. Squeeze the trigger to exit the Settings mode and save
your selection.
Cleaning
Do not immerse the RIDGID micro IR-200 Non-Contact Infrared
Thermometer in water. Wipe off dirt with a damp soft cloth. Do not
use aggressive cleaning agents or solutions. Treat the instrument as
you would a telescope or camera.
Storage
The RIDGID micro IR-200 Infrared Thermometer must be stored in
a dry secure area between -1C (1F) and 60°C (140°F).
Store the tool in a locked area out of the reach of children and peo-
ple unfamiliar with the micro IR-200.
ing the micro IR-200 to ensure good readings. To enable or disable,
while squeezing the trigger, press and release the laser enable but-
ton. The Laser Enable icon will be ON when the laser is enabled.
Backlight
If using in a low lit area, the micro IR-200 is equipped with a display
backlight. To turn the backlight ON and OFF, with the unit ON, press
the backlight button.
Menu Button Use
After squeezing the trigger, pressing and releasing the menu button
will allow you to cycle through the following settings in this order:
High Alarm ON/OFF, High Alarm Temperature Setting, Low Alarm
ON/OFF, Low Alarm Temperature Setting, Temperature Display
Units, Emissivity.
High Alarm
High Alarm will give an audible tone when the current temperature
exceeds a preset limit. To turn the High Alarm ON, squeeze and re-
lease the trigger, and then press and release the menu button until
the High Alarm icon is flashing. Use the up/down buttons to turn the
High Alarm feature ON/OFF as indicated on the current temperature
value
line. Press and release the menu button again. The High
Alarm icon will continue to flash, and the High Alarm temperature
will appear. Use the up/down buttons to change the High Alarm tem-
perature as desired. Sque
eze the trigger to exit the Settings mode
a
nd save your selection.
Low Alarm
Low Alarm will give an audible tone when the current temperature
falls below a preset limit. To turn the Low Alarm ON, squeeze and re-
lease the trigger, and then press and release the menu button until
the Low Alarm icon is flashing. Use the up/down buttons to turn the
Low Alarm feature ON/OFF as indicated on the current temperature
micro IR-200 Non-Contact Infrared Thermometer
12
Remove the battery before any long period of storage or shipping
to avoid battery leakage.
Service and Repair
WARNING
Improper service or repair can make the RIDGID micro IR-200
Non-Contact Infrared Thermometer unsafe to operate.
Service and repair of the micro IR-200 must be performed by a
RIDGID Independent Authorized Service Center.
For information on your nearest RIDGID Independent Service Cen-
ter or any service or repair questions:
Contact your local RIDGID distributor.
Visit www.RIDGID.com to find your local Ridge Tool contact point.
Contact Ridge Tool Technical Service Department at rtctechser-
vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
Disposal
Parts of the RIDGID micro IR-200 Non-Contact Infrared Thermo -
meter contain valuable materials and can be recycled. There are
companies that specialize in recycling that may be found locally.
Dispose of the com ponents in compliance with all applicable regu-
lations. Contact your local waste management authority for more
information.
For EC Countries: Do not dispose of elec trical equip-
ment with household waste!
According to the European Guideline 2002/ 96/EC for
Waste Electrical and Electronic Equipment and its imple -
men tation into national legislation, electrical equipment
that is no longer usable must be collected separately and disposed
of in an environmentally correct manner.
Battery Disposal
For EC countries: Defective or used batteries must be recycled ac-
cording to the guideline 2006/66/EEC.
Thermomètre infrarouge à distance
micro IR-200
Thermomètre infrarouge à distance micro IR-200
Pour future référence, notez ci-dessous le numéro de série de l’appareil indiqué sur sa plaque
signalétique.
de
rie
micro IR-200
AVERTISSEMENT
Familiarisez-vous bien avec le mode
d’emploi avant d’utiliser l’appareil.
L’incompréhension ou le non-respect
des consignes ci-après augmenter -
aient les risques de choc électrique,
d’incendie et/ou d’accident grave.
Utilisation de la touche «Menu»............................................24
Alarme température élevée ..................................................24
Alarme basse température ...................................................25
Unités d’affichage de température (°C/°F)............................25
Emissivité .............................................................................25
Nettoyage ................................................................................25
Stockage .................................................................................25
visions et réparations........................................................25
Recyclage de l’appareil..........................................................26
Recyclage des piles ...............................................................26
Garantie à vie ......................................................Page de garde
*Traduction du texte d’origine en anglais.
Table des matières
Fiche d’enregistrement du n° de série de l’appareil............13
Symboles de sécurité.............................................................15
Consignes générales de sécurité
Sécurité des lieux .................................................................16
Sécurité électrique ................................................................16
Sécurité individuelle..............................................................16
Utilisation et entretien du matériel ........................................16
Service après-vente..............................................................17
Consignes de sécurité particulières
Sécurité du thermomètre infrarouge .....................................17
Description, caractéristiques et équipements de base
Description............................................................................17
Caractéristiques ....................................................................18
Composants..........................................................................19
Icônes d’affichage ACL .........................................................20
Equipements de base...........................................................20
Classification du laser ...........................................................20
Enoncé FCC............................................................................20
Compatibilité électromagnétique (EMC) ..............................21
Remplacement et installation des piles ...............................21
Inspection préalable...............................................................21
Préparation et utilisation de l’appareil
Préparation ...........................................................................22
Fonctionnement
Activation, désactivation, prises de température ..................23
Commandes du micro IR-200
Mode «Scanning» (balayage de températures en continu) ...24
Activation/désactivation du laser ..........................................24
Eclairage de fond..................................................................24
Thermomètre infrarouge à distance micro IR-200
14
Thermomètre infrarouge à distance micro IR-200
15
Symboles de sécurité
Des symboles et mots clés spécifiques, utilisés à la fois dans ce mode d’emploi et sur l’appareil lui-même, servent à signaler d’importants
risques de sécurité. Ce qui suit permettra de mieux comprendre la signification de ces mots clés et symboles.
Ce symbole sert à vous avertir aux dangers physiques potentiels. Le respect des consignes qui le suivent vous permettra d’éviter
les risques de blessures graves ou mortelles.
Le terme DANGER signifie une situation dangereuse potentielle qui, faute d’être évitée, provoquerait la mort ou de graves
blessures corporelles.
Le terme AVERTISSEMENT signifie une situation dangereuse potentielle qui, faute d’être évitée, serait suscep-
tible d’entraîner la mort ou de graves blessures corporelles.
Le terme ATTENTION signifie une situation dangereuse potentielle qui, faute d’être évitée, serait susceptible d’en-
traîner des blessures corporelles légères ou modérées.
Le terme AVIS IMPORTANT signifie des informations concernant la protection des biens.
Ce symbole indique la nécessité de lire le manuel soigneusement avant d’utiliser le matériel. Le mode d’emploi renferme d’impor-
tantes informations concernant la sécurité d’utilisation du matériel.
AVIS IMPORTANT
DANGER
AVERTISSEMENT
ATTENTION
Ce symbole signale que l’appareil renferme un laser de Classe 2.
Ce symbole interdit de regarder dans le faisceau laser.
Ce symbole indique la présence d’un faisceau laser et des dangers
associés.
DO NOT STARE INTO BEAM
LASER RADIATION
MAXIMUM OUTPUT < 1mW
WAVELENGTH 630-670nm
CLASS 2 LASER PRODUCT
EN 60825-1:1994/A11:1996/A2:2001/A1:2002
CAUTION
* ATTENTION
Présence de faisceau laser. Ne pas regarder dans le faisceau.
Débit maximum : 1 mW. Longueur d’onde : 630-670 nm.
Laser Classe 2
*
vous êtes sous l’influence de drogues, de l’alcool ou de médica-
ments. Lors de l’utilisation d’un appareil électrique, un instant d’i-
nattention risque d’entraîner de graves lésions corporelles.
Pvoyez les équipements de protection individuelle néces-
saires. Portez systématiquement une protection oculaire. Le port
d’un masque à poussière, de chaussures de curité antidéra-
pantes, d’un casque de chantier ou de protecteurs d’oreilles s’im-
pose lorsque les conditions l’exigent.
Ne vous mettez pas en porte-à-faux. Maintenez une bonne
position de travail et un bon équilibre à tout moment. Cela
vous permettra de mieux contrôler l’appareil en cas d’imprévu.
Utilisation et entretien de l’appareil
Ne forcez pas l’appareil. Prévoyez un appareil adapté aux
travaux envisagés. L’appareil approprié fera le travail plus effi-
cacement et avec un plus grand niveau de sécurité lorsqu’il
tourne augime prévu.
N’utilisez pas l’appareil si son interrupteur marche/art ne
fonctionne pas correctement. Tout appareil qui ne peut pas être
contrôlé par son interrupteur est dangereux et doit être réparé.
Retirez le bloc-piles de l’appareil avant de le régler, de
changer ses accessoires ou de le ranger. De telles mesures
préventives limiteront les risques de blessure.
Rangez tout appareil non utilisé hors de la portée des en-
fants et des individus qui n’ont pas éfamiliarisés avec ce
type de matériel ou son mode d’emploi. Les appareils élec-
triques peuvent devenir dangereux s’ils tombent entre les mains
d’utilisateurs non initiés.
Veillez à l’entretien de l’appareil. Examinez-le pour signes de
désalignement, de grippage, d’absence ou de bris de ces
composants, et de toute autre anomalie qui risquerait de
nuire à son bon fonctionnement. Le cas échéant, faire ré-
Consignes générales de sécuri
AVERTISSEMENT
Familiarisez-vous avec l’ensemble du mode d’emploi. Le non-
respect des consignes d’utilisation et de sécurité ci-après aug-
menterait les risques de choc électrique, d’incendie et/ou de
grave blessure corporelle.
CONSERVEZ CES INSTRUCTIONS !
Sécurité des lieux
Assurez-vous de la propreté et du bon éclairage des lieux.
Les zones encombrées ou mal éclairées sont une invitation aux
accidents.
N’utilisez pas d’instruments électriques en présence de
matières explosives telles que liquides, gaz ou poussières
combustibles. Les appareils électriques produisent des étin-
celles susceptibles d’enflammer les poussières et émanations
combustibles.
Eloignez les enfants et les curieux lors de l’utilisation d’un
appareil électrique. Les distractions risquent de vous faire per-
dre le contrôle de l’appareil.
Sécurité électrique
Evitez tout contact physique avec les objets reliés à la terre
tels que canalisations, radiateurs, cuisinières et réfrigéra-
teurs. Tout contact avec la terre augmenterait les risques de choc
électrique.
N’exposez pas l’appareil à la pluie ou aux intempéries. Toute
pénétration d’eau à l’intérieur d’un appareil électrique aug-
menterait les risques de choc électrique.
Sécurité individuelle
Soyez attentif, faites attention à ce que vous faites et faites
preuve de bon sens. N’utilisez pas d’appareil électrique lorsque
Thermomètre infrarouge à distance micro IR-200
16
Thermomètre infrarouge à distance micro IR-200
17
Sécurité du thermomètre infrarouge
Ne pas regarder dans le faisceau laser de l’instrument. Le
faisceau laser est capable d’endommager la vue. Ne pas re-
garder vers le faisceau laser avec des jumelles, un télescope ou
autres aides oculaires.
Ne jamais orienter le faisceau laser vers autrui. S’assurer que
le laser est orienté plus haut ou plus bas que le niveau des yeux.
Tout faisceau laser est capable d’endommager la vue.
Soyez particulièrement attentif lors des travaux à proximité
d’éléments électriques, mécaniques ou brûlants. Un contact
rapproché risque de provoquer des chocs électriques, un
enchevêtrement, des brûlures ou autres graves blessures. Des
équipements de protection peuvent s’avérer nécessaires.
En cas de questions concernant ce produit Ridge Tool :
Consultez votre distributeur RIDGID
Consultez les sites www.RIDGID.com pour localiser le représen-
tant Ridge Tool le plus proche.
Consultez les services techniques de Ridge Tool par mail
adressé à rtctechservices@emerson.com, ou, à partir des Etats-
Unis et du Canada, en composant le (800) 519-3456.
Description, caractéristiques
techniques et équipements de base
Description
Le thermomètre infrarouge RIDGID
®
micro IR-200 fournit des me -
sures de température de surface à la fois simples, rapides et pré-
cises avec un seul appui de touche. Appuyez simplement sur la
chette en visant la surface avec les deux lasers classe II ultra
précis. La température relee s’affiche instantanément sur l’écran
à éclairage de fond du micro IR-200. En plus de nombreuses autres
parer l’appareil avant de l’utiliser. De nombreux accidents sont
provoqués par des appareils mal entretenus.
Servez-vous de l’appareil et de ses accessoires selon les
consignes ci-présentes en tenant compte des conditions de
travail et des travaux envisagés. L’utilisation de ce matériel à
des fins autres que celles prévues pourrait s’avérer dangereux.
Utilisez exclusivement les accessoires prévus par le fabri-
cant pour votre type d’appareil particulier. L’utilisation d’ac-
cessoires adaptés à d’autres types d’appareil risque de s’avérer
dangereuse.
Assurez la parfaite propreté de l’appareil. Cela permettra de
mieux le contrôler.
Révisions
Confiez les visions de ce matériel a un parateur qualif
utilisant exclusivement des pièces de rechange identiques
à celles d’origine. Cela assurera la sécurité intrinsèque du
matériel.
Consignes de sécurité spécifiques
AVERTISSEMENT
La section suivante contient d’importantes consignes de sécu-
rité qui s’adressent spécifiquement à ce type d’instrument.
Afin de limiter les risques d’incendie et de choc électrique ou
autres blessures graves, lisez le mode d’emploi soigneuse-
ment avant d’utiliser le thermomètre infrarouge RIDGID
®
micro
IR-200.
CONSERVEZ CES INSTRUCTIONS !
Gardez le présent manuel à portée de main de l’utilisateur.
applications, cet instrument compact et robuste permet au profes-
sionnel de diagnostiquer les problèmes de chauffage et de ventila-
tion, d’effectuer le contrôle préventif des moteurs et systèmes
électriques, de dépanner les soupapes à vapeur, et de rapidement
vérifier la température d’un boîtier à fusible ou coupe-circuit, le tout
sans avoir à toucher les éléments concernés.
Le micro IR-200 fait appel à un système optique pour relever l’én-
ergie émise, réfléchie et transmise, pour ensuite la renvoyer sur un
détecteur. Le système électronique de l’instrument traduit alors ces
informations sous forme de lecture de température affichée à
l’écran. Les lasers servent à viser la cible avec un maximum de pré-
cision.
Caractéristiques techniques
Plage de températures .................-50°C à 1200°C
(-58°F à 2192°F)
Rapport distance/point de mire.....30 : 1
Précision de mesure .....................-50°C à 20°C : ± 4,5%
ou 2,5°C
20°C à 800°C : ± 1%
ou 1,0°C
Prise de contrôle.............................-50°C à 20°C : ± 2,3#
ou 1,3°C
20°C à 800°C : ±0,5%
ou 0,5°C
Temps de réponse..........................150 m/s
Réponse spectrale .........................8 à 14 um
Emissivi .......................................Modulable de 0,10 à 1,00
Indicateur hors portée ....................Affichage LCD : « ---- »
Laser à diodes ..............................Puissance < 1mW, longueur
d’onde 630 à 670 nm, laser
Classe 2
Affichage de températures............Température actuelle,
température maximum
Unités de mesure..........................Fahrenheit, Celsius
Température opérationnelle ..........0°C à 50°C
Température de stockage .............-1C à 60°C
Résolution d’écran ..........................0,1°C
Humidité relative ...........................1Fonctionnement : 10% à
90%, stockage : <80%
Piles..............................................1 pile 9V type NEDA 1604a,
IEC 6LR61 ou équivalente
Grade IP .......................................IP54
Poids.............................................0,6 livres (300g)
Avantages
Fonction « mesure rapide »
Visée à deux lasers Classe II
Mémoire de données automatique
Affichage des températures maxi relevées
Mesures précises sans contact
Sélection de portée et résolution d’affichage automatique 0,1°C
Affichage LCD à éclairage de fond
Gâchette à verrouillage
Réglage des paramètres d’alarme de température élevée et
basse température
Emissivité modulable
Thermomètre infrarouge à distance micro IR-200
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325

RIDGID micro IR-200 Používateľská príručka

Typ
Používateľská príručka