Makita DVC665 Používateľská príručka

Kategória
Vysávače
Typ
Používateľská príručka
DVC665
EN Cordless Backpack Vacuum
Cleaner INSTRUCTION MANUAL 11
PL Akumulatorowy odkurzacz
plecakowy INSTRUKCJA OBSŁUGI 24
HU Vezeték nélküli háti porszívó HASZNÁLATI KÉZIKÖNYV 38
SK Plecniakový akumulátorový
vysávač NÁVOD NA OBSLUHU 52
CS Akumulátorový vysavač v
brašně na záda NÁVOD K OBSLUZE 65
UK Ранцевий акумуляторний
пилосос ІНСТРУКЦІЯ З
ЕКСПЛУАТАЦІЇ 78
RO Aspirator fără cablu de tip
rucsac MANUAL DE INSTRUCŢIUNI 92
DE Akku-Rucksackstaubsauger BETRIEBSANLEITUNG 106
2
1
3
3
Fig.1
1
2
Fig.2
2
1 2
1
Fig.3
1
2
Fig.4
1
2
Fig.5
2
1
Fig.6
1
Fig.7
2
1
Fig.8
Fig.9
1
2
3
Fig.10
1
2
Fig.11
1
2
3
Fig.12
1
2
Fig.13
1
2
3
Fig.14
3
1
2
3
Fig.15
1
2
Fig.16
1
2
3
Fig.17
1
234
Fig.18
1
3
2
4
Fig.19
1
Fig.20
1
2
3
Fig.21
4
1
Fig.22
Fig.23
Fig.24
1
2
Fig.25
1
2
Fig.26
2
1
3
Fig.27
5
1
11
1
4
3
2
Fig.28
Fig.29
Fig.30
2
1
Fig.31
1
Fig.32
1
Fig.33
Fig.34
6
1
Fig.35
21
3
4
Fig.36
2
3
1
Fig.37
1
Fig.38
1
2
2
1
Fig.39
Fig.40
7
1
Fig.41
2
1
Fig.42
1
Fig.43
1
2
2
1
Fig.44
3
1
2
Fig.45
1
2
Fig.46
8
1
Fig.47
2
3
1
Fig.48
Fig.49
1
Fig.50
9
1
Fig.51
1
23
Fig.52
3
2
1
Fig.53
10
11 ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model: DVC665
Capacity Filter bag 6.0 L
Dust bag 5.5 L
Maximum air volume
(With hose ø28 mm x 1.5 m)
1.8 m3/min
Vacuum 110 hPa
Dimensions (L x W x H)
(excluding the harness)
297 mm x 174 mm x 523 mm
Rated voltage D.C. 36 V
Net weight 6.1 - 6.7 kg
Due to our continuing program of research and development, the specications herein are subject to change without notice.
Specications may differ from country to country.
The weight does not include accessories but battery cartridge(s). The lightest and heaviest combination weight
of the appliance and battery cartridge(s) are shown in the table.
Applicable battery cartridge and charger
Battery cartridge BL1815N / BL1820 / BL1820B / BL1830 / BL1830B / BL1840 /
BL1840B / BL1850 / BL1850B / BL1860B
Charger DC18RC / DC18RD / DC18RE / DC18SD / DC18SE / DC18SF /
DC18SH
Some of the battery cartridges and chargers listed above may not be available depending on your region of residence.
WARNING: Only use the battery cartridges and chargers listed above. Use of any other battery cartridges
and chargers may cause injury and/or re.
Symbols
The followings show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read instruction manual.
Ni-MH
Li-ion
Only for EU countries
Do not dispose of electric equipment or
battery pack together with household
waste material! In observance of the
European Directives, on Waste Electric
and Electronic Equipment and Batteries
and Accumulators and Waste Batteries and
Accumulators and their implementation
in accordance with national laws, electric
equipment and batteries and battery
pack(s) that have reached the end of
their life must be collected separately and
returned to an environmentally compatible
recycling facility.
Intended use
The appliance is intended for collecting dry dust. The
appliance is suitable for commercial use, for example in
hotels, schools, hospitals, factories, shops, ofces and
rental businesses.
Noise
The typical A-weighted noise level determined accord-
ing to EN60335-2-69, EN60704-2-1:
Sound pressure level (LpA) : 70 dB(A) or less
Uncertainty (K) : 2.5 dB(A)
The noise level under working may exceed 80 dB (A).
NOTE: The declared noise emission value(s) has
been measured in accordance with a standard test
method and may be used for comparing one tool with
another.
NOTE: The declared noise emission value(s)
may also be used in a preliminary assessment of
exposure.
WARNING: Wear ear protection.
WARNING: The noise emission during actual
use of the power tool can differ from the declared
value(s) depending on the ways in which the
tool is used especially what kind of workpiece is
processed.
WARNING: Be sure to identify safety mea-
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
12 ENGLISH
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to EN60335-2-69:
Work mode: operation without load
Vibration emission (ah) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
NOTE: The declared vibration total value(s) has been
measured in accordance with a standard test method
and may be used for comparing one tool with another.
NOTE: The declared vibration total value(s) may also
be used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual
use of the power tool can differ from the declared val-
ue(s) depending on the ways in which the tool is used
especially what kind of workpiece is processed.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (tak-
ing account of all parts of the operating cycle such
as the times when the tool is switched off and when
it is running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
Cordless vacuum cleaner safety
warnings
WARNING: IMPORTANT! READ CAREFULLY
all safety warnings and all instructions BEFORE
USE . Failure to follow the warnings and instructions
may result in electric shock, re and/or serious injury.
1. Before use, make sure that this cleaner must
be used by people who have been adequately
instructed on the use of this cleaner.
2. Do not use the cleaner without the lter.
Replace a damaged lter immediately.
3. Do not attempt to pick up ammable materials,
re works, lighted cigarettes, hot ashes, hot
metal chips, sharp materials such as razors,
needles, broken glass or the like.
4. NEVER USE THE CLEANER IN THE VICINITY
OF GASOLINE, GAS, PAINT, ADHESIVES OR
OTHER HIGHLY EXPLOSIVE SUBSTANCES.
The switch emits sparks when turned ON and
OFF. And so does the motor commutator during
operation. A dangerous explosion may result.
5. Never vacuum up toxic, carcinogenic, com-
bustible or other hazardous materials such
as asbestos, arsenic, barium, beryllium,
lead, pesticides, or other health endangering
materials.
6. Never use the cleaner outdoors in the rain.
7. Do not use close to heat sources (stoves, etc.).
8. Do not block cooling vents. These vents per-
mit cooling of the motor. Blockage should be
carefully avoided otherwise the motor will burn
out from lack of ventilation.
9. Keep proper footing and balance at all times.
10. Do not fold, tug or step on the hose.
11. Stop the cleaner immediately if you notice
poor performance or anything abnormal
during operation.
12. DISCONNECT THE BATTERIES. When not in
use, before servicing, and when changing
accessories.
13. Clean and service the cleaner immediately
after each use to keep it in tiptop operating
condition.
14. MAINTAIN THE CLEANER WITH CARE. Keep
the cleaner clean for better and safer per-
formance. Follow instructions for changing
accessories. Keep handles dry, clean, and free
from oil and grease.
15. CHECK DAMAGED PARTS. Before further use
of the cleaner, a guard or other part that is
damaged should be carefully checked to deter-
mine that it will operate properly and perform
its intended function. Check for alignment of
moving parts, binding of moving parts, break-
age of parts, mounting, and any other condi-
tions that may affect its operation. A guard or
other part that is damaged should be properly
repaired or replaced by an authorized service
center unless otherwise indicated elsewhere
in this instruction manual. Have defective
switches replaced by authorized service cen-
ter. Don’t use the cleaner if switch does not
turn it on and off.
16. REPLACEMENT PARTS. When servicing, use
only identical replacement parts.
17. STORE IDLE CLEANER. When not in use, store
the cleaner indoors.
18.
Be kind to your cleaner. Rough handling can cause
breakage of even the most sturdily built cleaner.
19. Do not attempt to clean the exterior or interior
with benzine, thinner or cleaning chemicals.
Cracks and discoloration may be caused.
20. Do not use cleaner in an enclosed space where
ammable, explosive or toxic vapors are given
off by oil-base paint, paint-thinner, gasoline,
some mothproong substances, etc., or in
areas where ammable dust is present.
21. Do not operate the cleaner while under the
inuence of drugs or alcohol.
22. As a basic rule of safety, use safety goggles or
safety glasses with side shields.
23. Use a dust mask in dusty work conditions.
24. This machine is not intended for use by per-
sons including children with reduced physical,
sensory or mental capabilities, or lack of expe-
rience and knowledge.
25. Children should be supervised to ensure that
they do not play with the cleaner.
26. Never handle batteries and cleaner with wet
hands.
13 ENGLISH
27. Use extreme caution when cleaning on stairs.
28. Do not use the cleaner as a stool or work
bench. The machine may fall down and may
result in personal injury.
Battery tool use and care
1. Recharge only with the charger specied by
the manufacturer. A charger that is suitable for
one type of battery pack may create a risk of re
when used with another battery pack.
2. Use power tools only with specically desig-
nated battery packs. Use of any other battery
packs may create a risk of injury and re.
3. When battery pack is not in use, keep it away
from other metal objects, like paper clips,
coins, keys, nails, screws or other small metal
objects, that can make a connection from one
terminal to another. Shorting the battery termi-
nals together may cause burns or a re.
4. Under abusive conditions, liquid may be
ejected from the battery; avoid contact. If con-
tact accidentally occurs, ush with water. If
liquid contacts eyes, additionally seek medical
help. Liquid ejected from the battery may cause
irritation or burns.
5. Do not use a battery pack or tool that is dam-
aged or modied. Damaged or modied batteries
may exhibit unpredictable behaviour resulting in
re, explosion or risk of injury.
6. Do not expose a battery pack or tool to re or
excessive temperature. Exposure to re or tem-
perature above 130 °C may cause explosion.
7. Follow all charging instructions and do not
charge the battery pack or tool outside the
temperature range specied in the instruc-
tions. Charging improperly or at temperatures
outside the specied range may damage the
battery and increase the risk of re.
Service
1. Have your power tool serviced by a qualied
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
2. Follow instruction for lubricating and chang-
ing accessories.
3. Keep handles dry, clean and free from oil and
grease.
Important safety instructions for
battery cartridge
1. Before using battery cartridge, read all instruc-
tions and cautionary markings on (1) battery
charger, (2) battery, and (3) product using
battery.
2. Do not disassemble battery cartridge.
3. If operating time has become excessively
shorter, stop operating immediately. It may
result in a risk of overheating, possible burns
and even an explosion.
4. If electrolyte gets into your eyes, rinse them
out with clear water and seek medical atten-
tion right away. It may result in loss of your
eyesight.
5. Do not short the battery cartridge:
(1) Do not touch the terminals with any con-
ductive material.
(2) Avoid storing battery cartridge in a con-
tainer with other metal objects such as
nails, coins, etc.
(3) Do not expose battery cartridge to water
or rain.
A battery short can cause a large current
ow, overheating, possible burns and even a
breakdown.
6. Do not store the tool and battery cartridge in
locations where the temperature may reach or
exceed 50 °C (122 °F).
7. Do not incinerate the battery cartridge even if
it is severely damaged or is completely worn
out. The battery cartridge can explode in a re.
8. Be careful not to drop or strike battery.
9. Do not use a damaged battery.
10.
The contained lithium-ion batteries are subject to
the Dangerous Goods Legislation requirements.
For commercial transports e.g. by third parties,
forwarding agents, special requirement on pack-
aging and labeling must be observed.
For preparation of the item being shipped, consult-
ing an expert for hazardous material is required.
Please also observe possibly more detailed
national regulations.
Tape or mask off open contacts and pack up the
battery in such a manner that it cannot move
around in the packaging.
11. When disposing the battery cartridge, remove
it from the tool and dispose of it in a safe
place. Follow your local regulations relating to
disposal of battery.
12. Use the batteries only with the products
specied by Makita. Installing the batteries to
non-compliant products may result in a re, exces-
sive heat, explosion, or leak of electrolyte.
13. If the tool is not used for a long period of time,
the battery must be removed from the tool.
SAVE THESE INSTRUCTIONS.
CAUTION: Only use genuine Makita batteries.
Use of non-genuine Makita batteries, or batteries that
have been altered, may result in the battery bursting
causing res, personal injury and damage. It will
also void the Makita warranty for the Makita tool and
charger.
Tips for maintaining maximum
battery life
1. Charge the battery cartridge before completely
discharged. Always stop tool operation and
charge the battery cartridge when you notice
less tool power.
2.
Never recharge a fully charged battery cartridge.
Overcharging shortens the battery service life.
3.
Charge the battery cartridge with room tempera-
ture at 10 °C - 40 °C (50 °F - 104 °F). Let a hot
battery cartridge cool down before charging it.
4. Charge the battery cartridge if you do not use
it for a long period (more than six months).
14 ENGLISH
Important safety instructions for
wireless unit
1. Do not disassemble or tamper with the wire-
less unit.
2. Keep the wireless unit away from young chil-
dren. If accidentally swallowed, seek medical
attention immediately.
3. Use the wireless unit only with Makita tools.
4. Do not expose the wireless unit to rain or wet
conditions.
5. Do not use the wireless unit in places where
the temperature exceeds 50°C (122°F).
6. Do not operate the wireless unit in places
where medical instruments, such as heart
pace makers are nearby.
7. Do not operate the wireless unit in places
where automated devices are nearby. If oper-
ated, automated devices may develop malfunction
or error.
8. Do not operate the wireless unit in places
under high temperature or places where
static electricity or electrical noise could be
generated.
9. The wireless unit can produce electromagnetic
elds (EMF) but they are not harmful to the
user.
10. The wireless unit is an accurate instrument. Be
careful not to drop or strike the wireless unit.
11. Avoid touching the terminal of the wireless
unit with bare hands or metallic materials.
12. Always remove the battery on the product
when installing the wireless unit into it.
13. When opening the lid of the slot, avoid the
place where dust and water may come into the
slot. Always keep the inlet of the slot clean.
14. Always insert the wireless unit in the correct
direction.
15. Do not press the wireless activation button
on the wireless unit too hard and/or press the
button with an object with a sharp edge.
16. Always close the lid of the slot when
operating.
17. Do not remove the wireless unit from the slot
while the power is being supplied to the tool.
Doing so may cause a malfunction of the wireless
unit.
18. Do not remove the sticker on the wireless unit.
19. Do not put any sticker on the wireless unit.
20. Do not leave the wireless unit in a place where
static electricity or electrical noise could be
generated.
21. Do not leave the wireless unit in a place sub-
ject to high heat, such as a car sitting in the
sun.
22. Do not leave the wireless unit in a dusty or
powdery place or in a place corrosive gas
could be generated.
23. Sudden change of the temperature may bedew
the wireless unit. Do not use the wireless unit
until the dew is completely dried.
24. When cleaning the wireless unit, gently wipe
with a dry soft cloth. Do not use benzine, thin-
ner, conductive grease or the like.
25. When storing the wireless unit, keep it in the
supplied case or a static-free container.
26. Do not insert any devices other than Makita
wireless unit into the slot on the tool.
27. Do not use the tool with the lid of the slot dam-
aged. Water, dust, and dirt come into the slot may
cause malfunction.
28. Do not pull and/or twist the lid of the slot more
than necessary. Restore the lid if it comes off
from the tool.
29. Replace the lid of the slot if it is lost or
damaged.
SAVE THESE INSTRUCTIONS.
FUNCTIONAL
DESCRIPTION
CAUTION: Always be sure that the appli-
ance is switched off and the battery cartridge is
removed before adjusting or checking function on
the appliance.
Installing or removing battery
cartridge
CAUTION: Always switch off the appliance
before installing or removing of the battery
cartridge.
CAUTION: Hold the appliance and the bat-
tery cartridge rmly when installing or removing
battery cartridge. Failure to hold the appliance and
the battery cartridge rmly may cause them to slip off
your hands and result in damage to the appliance and
battery cartridge and a personal injury.
Fig.1: 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the
appliance while sliding the button on the front of the
cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION: Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the appliance, causing
injury to you or someone around you.
CAUTION: Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
15 ENGLISH
Appliance / battery protection
system
The appliance is equipped with a appliance / battery
protection system. This system automatically cuts off
power to the motor to extend appliance and battery life.
The appliance will automatically stop during operation
if the appliance or battery is placed under one of the
following conditions.
Overload protection
When the appliance is operated in a manner that
causes it to draw an abnormally high current, the appli-
ance automatically stops without any indication. In this
situation, turn the appliance off and stop the application
that caused the appliance to become overloaded. Then
turn the appliance on to restart.
Overheat protection
When the appliance is overheated, the appliance stops
automatically. Let the appliance cool down before turn-
ing the appliance on again.
Overdischarge protection
When the battery capacity becomes low, the appliance
stops automatically. If the product does not operate
even when the switches are operated, remove the bat-
teries from the appliance and charge the batteries.
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
Fig.2: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Indicator lamps Remaining
capacity
Lighted Off Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have
malfunctioned.
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
Switch box position
The switch box can be hooked on either side of the lower
belt. Arrange the cord so that the switch box comes to
your desired side. To prevent the cord from being dam-
aged, pass the cord through the groove as illustrated.
Fig.3: 1. Groove 2. Cord
Adjusting belts
The tightness of the shoulder belts, upper and lower belts can
be adjusted. Put your arms through the shoulder belts rst then
fasten the lower and upper belts. To tighten, pull the end of the
strap as illustrated. To loosen, pull up the end of the fastener.
Lower belt
Fig.4: 1. Strap 2. Fastener
Shoulder belts
Fig.5: 1. Strap 2. Fastener
Upper belt
Fig.6: 1. Strap 2. Fastener
Carrying hook
Always grab the carrying hook when handling the vac-
uum cleaner body.
Fig.7: 1. Carrying hook
Stand-by switch
The stand-by switch is the switch to turn on/off the
wireless activation function. The vacuum cleaner is in
the stand-by state regardless of the switch position and
it runs when button is pushed.
Fig.8: 1. Stand-by switch
Switch position Status
AUTO I
(ON)
The vacuum cleaner is in the stand-by
state and the wireless activation function
is available.
O
(OFF)
The vacuum cleaner is in the stand-by
state however the wireless activation
function is not available.
Switch action
To start vacuuming, press button once. The vacuum cleaner
will start in the same suction power when you turned it off previ-
ously. When you press button while the vacuum cleaner is run-
ning, the suction power switches between normal (1) and higher
(2) suction power. To turn off the vacuum cleaner, press button.
Fig.9
NOTE: If you want to run the vacuum cleaner along
with the switch operation of the tool connected to the
vacuum cleaner (wireless activation function), set the
stand-by switch to " I (ON)".
NOTE: To use the wireless activation function, nish
the tool registration beforehand. Refer to "WIRELESS
ACTIVATION FUNCTION" section for detail.
NOTE: When using the wireless activation func-
tion, you will not be able to stop the vacuuming
by button.
16 ENGLISH
Hose band
Hose band can be used for holding the hose or free
nozzle.
To secure the hose to the vacuum cleaner body, pass
the hose band through the slot on the body. You can
attach the hose band on either side.
Fig.10: 1. Hose band 2. Slot 3. Hose
The loop on the lower belt can be used for carrying
nozzles as illustrated.
Fig.11: 1. Loop 2. Nozzles
Dust beating system
Dust goes down when you pull the lever or walk with
wearing the cleaner. This system helps the cleaner
maintaining the suction power.
Fig.12: 1. Lever 2. Filter bag/dust bag 3. Board
NOTE: This function works when the cleaner is
switched off and the lter bag/dust bag contains a
certain amount of dust to touch the board.
ASSEMBLY
CAUTION: Always be sure that the appli-
ance is switched off and the battery cartridge
is removed before carrying out any work on the
appliance.
Assembling hose
Insert the hose cuff into the vacuum cleaner body and
turn it clockwise.
Fig.13: 1. Hose cuff 2. Vacuum cleaner body
Connecting the tool
If the bent pipe assembly is attached to the hose,
loosen the sleeve of bent pipe assembly and remove it.
Fig.14: 1. Hose 2. Bent pipe assembly 3. Sleeve
1. Attach the front cuff to the hose for dust extraction.
When connecting the front cuff, make sure that it is
securely screwed on the hose.
2. Connect the front cuff to the tool's extraction
outlet.
Fig.15: 1. Front cuff 2. Extraction outlet 3. Hose
The front cuff can be detached by turning it counter-
clockwise while holding the hose.
NOTE: Always use a suitable front cuff. When using
the front cuff 24, attach it to the front cuff 22 that is
connected to the hose.
Fig.16: 1. Front cuff 22 2. Front cuff 24
Using as a cleaner
If you want to use this product as a cleaner, follow the
below procedures.
NOTICE: If the front cuff is attached to the hose,
remove it beforehand.
NOTE: The bent pipe assembly, extension wand, and
nozzles are supplied as optional accessories in some
countries.
NOTE: There are two types of bent pipe assembly;
the one for slide-type extension wand and the one for
ring-type extension wand. If you prepare the bent pipe
assembly, choose the one for your desired extension
wand type.
1.
Fasten the sleeve of bent pipe assembly onto the hose.
Fig.17: 1. Hose 2. Bent pipe assembly 3. Sleeve
To remove the bent pipe assembly, loosen the sleeve of
bent pipe assembly from the hose.
2. Twist and insert the nozzle to the extension wand.
Fig.18: 1. Extension wand 2. Free nozzle
3. T-shape nozzle 4. T-shape nozzle (slim)
NOTE: By twisting the nozzle while inserting, the noz-
zle can be attached to the extension wand securely.
3. Follow the procedures below, depending on the
type of the extension wand :
NOTE: The slide-type extension wand and the ring-
type extension wand are not compatible with each
other. If you want to change the slide-type extension
wand to the ring-type extension wand or vice versa,
change the bent pipe assembly also.
NOTE: The free nozzle can be attached to the bent
pipe assembly directly.
For the slide-type extension wand
Shoulder the vacuum cleaner body then insert the
extension wand into the bent pipe assembly until it
clicks. To disconnect, extract the extension wand with
pressing the button.
Fig.19: 1. Bent pipe assembly 2. Button 3. Slide-
type extension wand 4. Free nozzle
The length of the wand can be adjusted.
With pressing the slide button, adjust the wand length.
The length is locked when releasing the slide button.
Fig.20: 1. Slide button
For the ring-type extension wand
Shoulder the vacuum cleaner body then twist and insert
the extension wand into the bent pipe assembly. To
disconnect, twist and extract it.
Fig.21: 1. Bent pipe assembly 2. Ring-type exten-
sion wand 3. Free nozzle
The length of the wand can be adjusted.
Loosen the ring on the wand and adjust the wand
length. Tighten the ring at your desired length.
Fig.22: 1. Ring
Hose hook
When you suspend the operation, the hook on the bent pipe
assembly can be used for hanging the wand on the lower belt.
Fig.23
17 ENGLISH
Installing lter bag / dust bag
Optional accessory
CAUTION: Do not use a damaged lter bag.
Always use the vacuum cleaner with the lter bag
properly installed. Otherwise the vacuumed dust
or particles may be exhausted from the cleaner
and they may cause respiratory disease to the
operator.
Install either dust bag or lter bag before using cleaner.
Dust bag are usable many times repeatedly by
cleaning it out.
Filter bag is a throw-away type. Throw away the
entire lter bag without emptying when it has
become full.
NOTICE: When the lter bag is already full,
replace with new one. When the dust bag is
already full, empty it. Continuous use with the lter
bag/dust bag full results in reduced suction power.
NOTICE: To prevent dust from getting into the
motor:
Make sure that the lter bag/dust bag is
installed before use.
Do not use a broken or ripped bag.
Otherwise the motor may be broken.
NOTICE: Do not fold the cardboard at its open-
ing when installing the lter bag/dust bag.
NOTICE: The lter bag/dust bag for the cleaner
is an important component for maintaining the
appliance performance. Using non-genuine lter
bag/dust bag may cause smoke or ignition.
NOTE: When the lter bag/dust bag is not installed in
the cleaner, the front cover does not close completely.
Fig.24
1. Unlock the latch by lifting the bottom side. Push
the grooved area to lift the front latching side. Pull the
latch to open the lid.
Fig.25: 1. Hook 2. Lid
2. Insert the lter bag into the slit on the upper side of
the room as illustrated.
Fig.26: 1. Slit 2. Filter bag
When using the dust bag, insert the brim of the dust bag
into the slit.
Fig.27: 1. Slit 2. Brim 3. Dust bag
3. Align the hole of the lter bag with the hose cuff
and push the cardboard portion to the end. Make sure
that the rubber ring on the lter bag goes over the rim
on the hose cuff.
Fig.28: 1. Rubber ring on the lter bag 2. Rim on
the hose cuff 3. Cardboard portion of the
lter bag 4. Hose cuff
OPERATION
WARNING: Operators shall be adequately
instructed on the use of the vacuum cleaner.
WARNING: This vacuum cleaner is not suit-
able for picking up hazardous dust.
CAUTION: This cleaner is for dry use only.
CAUTION: This cleaner is for indoor use only.
CAUTION: Always insert the battery cartridge
all the way until it locks in place. If you can see the
red indicator on the upper side of the button, it is not
locked completely. Insert it fully until the red indicator
cannot be seen. If not, it may accidentally fall out
of the appliance, causing injury to you or someone
around you.
CAUTION: During operation, be conscious
of the vacuum cleaner on your back. You may
lose your balance if the vacuum cleaner body bumps
against a wall or the hose is hooked by an obstacles.
1. Shoulder the vacuum cleaner body and fas-
ten lower and upper belts. Adjust the tightness as
necessary.
Fig.29
2. Press
button to start vacuuming. To change
the suction power, press button while the vacuum
cleaner is running. The suction power switches between
normal (1) and higher (2) suction power. Press but-
ton to stop.
Fig.30
During the operation, hook the switch box on the lower
belt or the ring.
Fig.31: 1. Ring 2. Lower belt
3. Replace the lter bag when it becomes full. Open
the lid and take out the lter bag. Pull the strip on the
side of the opening to shut the lter bag and dispose of
the lter bag in whole.
Fig.32: 1. Strip
When using a dust bag, take out the dust bag and dis-
pose of the dust by releasing the latch.
Fig.33: 1. Latch
NOTICE: Do not put lter bag/dust bag or other
heavy objects on the lid. The appliance may fall
down.
NOTICE: Periodically check the lter bag if it is
full. Continuous use with the lter bag full results in
reduced suction power.
NOTICE: Do not use an used lter bag. The lter
bag is designed for single use. Using lter bag repeat-
edly may cause clogging of the lter and results in
damage to the cleaner. If you want to use the bag
repeatedly, use a dust bag.
18 ENGLISH
WIRELESS ACTIVATION
FUNCTION
What you can do with the wireless
activation function
The wireless activation function enables clean and comfortable oper-
ation. By connecting a supported tool to the cleaner, you can run the
cleaner automatically along with the switch operation of the tool.
Fig.34
NOTICE: Be sure to refer to the instruction man-
ual of the tool when using the cleaner with wire-
less activation function.
NOTICE: Do not disassemble or tamper with the
wireless unit.
NOTICE: To prevent dust coming into the slot
of the wireless unit, always close the lid securely
during operation and storage.
NOTICE: Do not remove the wireless unit while
the power is being supplied. Doing so may cause a
malfunction of the wireless unit.
NOTICE:
Do not press the wireless activation button too
hard and/or press the button with an object with a sharp edge.
NOTE: Wireless activation needs Makita tools
equipped with the wireless unit.
NOTE:
Prior to the initial use of the wireless activation
function with each tool, the tool registration is required.
Once the registration is nished with the tool, the
re-registration is not required unless it is cancelled.
NOTE: Before registration, be sure that the wireless
unit is properly inserted.
NOTE: One wireless unit can register up to 10 links
with other wireless units. If more than 10 other wire-
less units are registered to one wireless unit, the one
registered earliest will be cancelled automatically.
NOTE: The position of the wireless activation button
varies depending on the tool.
NOTE: The cleaner also starts by pressing button
when the stand-by switch is set to " I (ON)".
However the button will not work when the wire-
less activation function is used.
Installing the wireless unit
CAUTION: Place the cleaner on a at and
stable surface when installing the wireless unit.
NOTICE:
Clean the dust and dirt on the cleaner
before installing the wireless unit. Dust or dirt may cause
malfunction if it comes into the slot of the wireless unit.
NOTICE:
To prevent the malfunction caused by
static, touch a static discharging material, such as
a metallic part, before picking up the wireless unit.
NOTICE:
When installing the wireless unit, always
be sure that the wireless unit is inserted in the cor-
rect direction and the lid is completely closed.
1. Open the lid on the cleaner as shown in the gure.
Fig.35: 1. Lid
2. Insert the wireless unit to the slot and then close
the lid.
When inserting the wireless unit, align the projections
with the recessed portions on the slot.
Fig.36: 1. Wireless unit 2. Projection 3. Lid
4. Recessed portion
When removing the wireless unit, open the lid slowly.
The hooks on the back of the lid will lift the wireless unit
as you pull up the lid.
Fig.37: 1. Wireless unit 2. Hook 3. Lid
After removing the wireless unit, keep it in the supplied
case or a static-free container.
NOTICE: Always use the hooks on the back of
the lid when removing the wireless unit. If the
hooks do not catch the wireless unit, close the lid
completely and open it slowly again.
Tool registration for the cleaner
NOTE: A Makita tool supporting the wireless activa-
tion function is required for the tool registration.
NOTE: Finish installing the wireless unit to the tool
before starting the tool registration.
NOTE: During the tool registration, do not pull the
switch trigger on the tool or push the cleaner's switch
for vacuuming.
NOTE: Refer to the instruction manual of the tool, too.
If you wish to activate the cleaner along with the
switch operation of the tool, nish the tool registration
beforehand.
1. Install the wireless units to the cleaner and the
tool, respectively.
2. Install the batteries to the cleaner and the tool.
3. Set the stand-by switch on the cleaner to " I (ON)".
Fig.38: 1. Stand-by switch
4. Press the wireless activation button on the cleaner
for 3 seconds until the wireless activation lamp blinks in
green. And then press the wireless activation button on
the tool in the same way.
Fig.39: 1. Wireless activation button 2. Wireless
activation lamp
If the cleaner and the tool are linked successfully, the
wireless activation lamps will light up in green for 2
seconds and start blinking in blue.
NOTE: The wireless activation lamps nish blinking
in green after 20 seconds elapsed. Press the wireless
activation button on the tool while the wireless acti-
vation lamp on the cleaner is blinking. If the wireless
activation lamp does not blink in green, push the wire-
less activation button briey and hold it down again.
NOTE: When performing two or more tool registration
for the cleaner, nish the tool registration one by one.
19 ENGLISH
Starting the wireless activation
function
NOTE: Finish the tool registration for the cleaner for
wireless activation.
NOTE: Always place the cleaner so that you can see
the status of the wireless activation lamp.
NOTE: Refer to the instruction manual of the tool, too.
After registering a tool to the cleaner, the cleaner will
automatically runs along with the switch operation of
the tool.
1. Install the wireless units to the cleaner and the
tool, respectively.
2. Install the batteries to the cleaner and the tool.
3. Connect the hose of the cleaner with the tool.
Fig.40
4. Set the stand-by switch on the cleaner to " I (ON)".
The wireless activation lamp will blink in blue.
Fig.41: 1. Stand-by switch
5. Push the wireless activation button on the tool
briey. The wireless activation lamp will blink in blue.
Fig.42: 1. Wireless activation button 2. Wireless
activation lamp
6. Pull the switch trigger of the tool. Check if the
cleaner runs while the switch trigger on the tool is being
pulled.
CAUTION: Always check if the wireless acti-
vation function works before starting a work with
the tool.
To stop the wireless activation, push the wireless activa-
tion button on the tool or set the stand-by switch on the
cleaner to "O (OFF)".
NOTE: The wireless activation lamp on the tool will
stop blinking in blue when there is no operation for
2 hours. In this case, press the wireless activation
buttons on the tool again.
NOTE: The cleaner starts/stops with a delay. There is
a time lag when the cleaner detects a switch opera-
tion of the tool.
NOTE: The transmission distance of the wireless unit
may vary depending on the location and surrounding
circumstances.
NOTE: When two or more tools are registered to one
cleaner, the cleaner may start running even if you
don't pull the switch trigger because other user is
using the wireless activation function.
Cancelling tool registration for the
cleaner
Perform the following procedure when cancelling the
tool registration for the cleaner.
1. Install the wireless units to the cleaner and the
tool, respectively.
2. Install the batteries to the cleaner and the tool.
3. Set the stand-by switch on the cleaner to " I (ON)".
Fig.43: 1. Stand-by switch
4. Press the wireless activation button on the cleaner
for 6 seconds. The wireless activation lamp blinks in
green and then become red. After that, press the wire-
less activation button on the tool in the same way.
Fig.44: 1. Wireless activation button 2. Wireless
activation lamp
If the cancellation is performed successfully, the wire-
less activation lamps will light up in red for 2 seconds
and start blinking in blue.
NOTE: The wireless activation lamps nish blinking in
red after 20 seconds elapsed. Press the wireless acti-
vation button on the tool while the wireless activation
lamp on the cleaner is blinking. If the wireless acti-
vation lamp does not blink in red, push the wireless
activation button briey and hold it down again.
Erasing all tool registrations
You can erase all tool registrations from the cleaner as
follows.
Fig.45: 1. Stand-by switch 2. Wireless activation
button 3. Wireless activation lamp
1. Install the wireless unit to the cleaner.
2. Install the batteries to the cleaner.
3. Set the stand-by switch to " I (ON)".
4. Hold down the wireless activation button for about
6 seconds until the wireless activation lamp blinks in red
(about twice per one second).
5. When the wireless activation lamp starts blinking
in red, release your nger from the wireless activation
button. Thereafter, hold down the wireless activation
button again for about 6 seconds.
6. When the wireless activation lamp starts blinking
fast (about 5 times per one second) in red, release your
nger from the wireless activation button. When the
wireless activation lamp lights up in red and later lights
off, all tool registrations are erased.
NOTE: If the wireless activation lamp does not blink
in red, press the wireless activation button briey and
try again.
20 ENGLISH
Description of the wireless activation lamp status
Fig.46: 1. Wireless activation button 2. Wireless
activation lamp
The wireless activation lamp shows the status of the wireless activation function. Refer to the below table for the
meaning of the lamp status.
Status Wireless activation lamp Description
Color
On
Blinking
Duration
(approximate)
Standby Blue Cleaner: con-
tinuing
Tool: 2 hours
Waiting for the tool registration or the wireless activation function
is available.
The lamp on the cleaner blinks when the stand-by switch is set in
" I (ON)". The lamp on the tool blinks when the wireless activation
button is pushed. The lamp on the tool will automatically turn off
when no operation is performed for 2 hours.
When the tool is
running.
The wireless activation of the cleaner is available and the tool is
running.
Tool
registration
Green 20 seconds Ready for the tool registration. Searching the tool to be registered.
2 seconds The tool registration has been nished. The wireless activation
lamp will start blinking in blue.
Cancelling/
erasing
tool
registration
Red
(slow: 2 times/sec.)
20 seconds Ready for the cancellation of the tool registration. Searching the
tool to be cancelled.
(fast: 5 times/sec.)
When the
wireless acti-
vation button is
pressed down.
Ready to erase all tool registrations.
2 seconds The tool registration has been cancelled/erased. The wireless
activation lamp will start blinking in blue.
Others Red 3 seconds The power is supplied to the wireless unit and the wireless activa-
tion function is starting up.
Off - - The stand-by switch is not set to " I (ON)".
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120

Makita DVC665 Používateľská príručka

Kategória
Vysávače
Typ
Používateľská príručka