Dear customer,
Thank you for purchasing our product. Please read the following instructions carefully
before first use and keep this user manual for future reference. Pay particular attention
to the safety instructions. If you have any questions or comments about the device,
please contact the customer line.
www.alza.co.uk/kontakt
+44 (0)203 514 4411
Importer Alza.cz a.s., Jankovcova 1522/53, Holešovice, 170 00 Praha 7, www.alza.cz
4
Important Safety Warning
Make sure not to cause any short circuit when connecting the solar controller.
Children should not be aware of the dangers of electrical equipment. Please
place the charger in a place where children cannot reach.
Do not touch the exposed conductor on the DC side without protective
measures.
Ensure good ventilation, put the charger in a dry place, do not put the charger in
a corrosive, salty, flammable and explosive gas, high temperature, rain and damp
environment.
Please do not attempt to disassemble or modify any part not described in this
manual. Disassembling or modifying this product may cause serious accidents.
Internal inspection, modification or repair should be handled by the distributor of
this product or the qualified service personnel designated by the manufacturer.
Solar panel open circuit voltage is too high (especially 24V and 48V systems),
please be careful.
The battery power is high, and any conductor is prohibited to short-circuit
between the positive and negative electrodes of the battery. It is recommended
to add a fuse between the battery and the controller. (Slow motion type, the
operating current of the fuse should be 1.5 times the rated current of the
controller.)
The main function
Automatic identification of system voltage, 12V/24V/48V automatic identification.
Humanized LCD screen display, man-machine interface two-key operation.
Technical parameters modified according to battery customization.
High-efficiency and intelligent PWM three-stage charging mode.
The load control mode can be selected, and the timer function of the night street
light can be reset.
Work storage function: record the total running time of the system, record the
running error timer, and record the number of times the battery is fully charged.
And can query the charge and discharge capacity.
Reliable overvoltage protection, short circuit protection, overload protection,
overcharge protection, overdischarge protection and reverse connection
protection.
Precise temperature compensation, automatic correction of charge and
discharge voltage, improve battery life.
Solar panels, batteries, and solar charge controller anodes are all connected
together, and a negative MOSFET series control circuit is adopted.
5
Recommendations
The controller can adjust the charging voltage by detecting the ambient
temperature, so that the controller is as close to the battery as possible.
It is recommended that the system current density of the cable is less than
3A/mm2.
Use multiple strands of copper wire as much as possible to connect firmly to the
terminal. Loose power connections and/or wire corrosion may cause resistance
connections, melt wire insulation, burn surrounding materials, and even cause a
fire.
The battery should be fully charged every month. Otherwise, the battery will be
destroyed.
LCD Features of graphic symbols
1. The default night display of the controller: When the controller detects that the
input voltage of the solar panel is less than the voltage of the sensor
identification point, this graphic symbol is on.
2. The default daytime display of the controller: When the controller detects that
the input voltage of the solar panel exceeds the voltage of the sensor
identification point, this graphic symbol is on.
3. Photovoltaic array parameter indication: This graphic symbol is displayed when
the solar panel data is displayed. For example, the voltage of solar panels.
4. Battery parameter indication: When the battery parameter is displayed, this
graphic symbol is displayed. For example, battery voltage, battery temperature.
5. Load parameter indication: When the load parameter is displayed, this graphic
symbol is displayed.
6
6. System voltage: When the LCD displays different system voltages, the controller
will automatically adjust the technical parameters.
7. Numerical display area.
8. Timer setting function.
9. Load and switch graphic symbols.
10. Unit symbol value.
11. Warning: When a fault occurs, this graphic symbol will flash.
12. Load status indicator: load is on, load is off.
13. Output power indication: When there is output at the load end, this graphic
symbol flashes.
14. Battery capacity indicator: When the battery is in different capacities, the
corresponding capacity will be displayed in a bar.
15. Charging status indication: When the controller is charging, the indicating arrow
is on, the floating charge is flashing, and it is not displayed when it is not
charging.
Installation Notes
Controller fixed
1. The controller should be installed in a well-ventilated place, avoid direct sunlight, high
temperature, and do not install where water can enter the controller.
2. Please select the correct screws to fix the controller on the wall or other platforms.
Screw M4,
the diameter of the screw cover is less than 10mm.
3. Please reserve enough space between the wall and the controller for cooling and
cable connection.
7
Controller connection
1. All terminals are in a fastened state after leaving the factory, in order to connect well,
please loosen all terminals first.
2. Please do not change the following wiring sequence at will, otherwise it will cause
system voltage identification failure.
8
3. As shown in the figure, first connect the battery to the correct pole of the controller.
To avoid short circuit, please screw the battery cable to the controller in advance, and
then connect the battery pole. If your connection is correct, the LCD will display battery
voltage and other technical data. If the LCD screen does not display, please check the
fault. The shorter the cable length between the battery and the controller, the better.
Suggest 30CM -100CM.
Charger Controller
If the controller terminals are short-circuited, it may cause fire or explosion. be
careful. (It is strongly recommended to connect a fuse 1.5 times the rated current of the
controller on the battery side)
If the battery is connected in reverse, the output of the controller will have the
same polarity as the battery. Please do not connect any load to the controller at this
time, otherwise the load and the controller will be damaged.
Solar Panel
Load
Battery
Power Inverter
9
4. As shown in the figure, connect the solar panel and the controller correctly. If the
connection is successful and the sun is sufficient, the LCD will display the sun's graphics
and the arrow from the sun to the battery will be displayed.
The voltage of solar panels under sunlight is very high, and high voltage can cause injury
or damage the controller. As shown in the figure, the load is correctly connected to the
controller.
In the 48V system, the reverse connection of the solar panel will destroy the solar charge
controller.
In order to avoid the load voltage damage, please use the button to approach the output
of the controller first, and then connect the load to the controller. The controller does
not provide load reverse connection protection, please be careful, the load reverse
connection will damage the bulb.
About connecting the solar system to the ground
Please note that the negative pole of the solar charge controller battery is connected to
the shell, which can be used to connect the device negative to the ground system.
Warning: For some equipment positive-to-ground connection systems, such as
solar communication systems and portable solar systems, please do not connect the
equipment ground wire to the control system casing directly at this time, otherwise it
will cause a short circuit.
Operation and instructions
Main interface
After the controller is powered on, there will be a 1s initialization interface, enter the
main interface.
1S later
10
When there is no operation in the main interface for 20s, the main interface will switch
automatically when the battery voltage, solar panel voltage, load current, charging
current, ambient temperature and other interfaces are maintained for 3s. Long press "
"on the main interface for more than 5s to accelerate automatic exchange. Release
the button to stop the speed.
Press " " under the main interface to turn on or off the load output.
Long press " and " and hold on the main interface for more than 5s, and the
working storage interface opens, automatically displaying the number of working days,
the number of insufficient battery times, the number of full batteries, and the number of
overcurrent protection.
Main interface
Working days
Number of low voltage
Number of over current
Number of charge full
11
Press " " key to enter the next menu of the main interface.
a. Accumulated charging power (AH)
This parameter is the charge AH counter, which shows the total power generation
capacity of the solar panel. Press " " and hold for more than 5s in this interface, the
counter will return to zero.
Accumulated Charging Power (AH)
b. Cumulative discharge power (AH)
This parameter is the discharge AH counter, which shows the power consumption of the
load. In this interface, press " "and hold for more than 5s, the counter can return to
zero.
Accumulated Discharging Power (AH)
Main interface
Accumulated Charging
Power (AH)
Accumulated Discharging Power (AH)
Load disconnect voltage
Load reconnect voltage
Float voltage
Load mode
Load rationing
System voltage select
To Main interface
12
c. Float voltage setting
This parameter is the high voltage disconnect (HVD) voltage. (Increase the boost voltage
by 0.6V based on HVD) At this time, the controller starts the PWM function (HVD) to limit
the boost.
Press " " to join the float voltage menu. Long press the " " key 5S, the
interface parameter is flash, here is the setting state. Release the button and press the
" key to add data and press the " " key to subtract data. After completing the
required technical data, long press the " " key again, 5S, the parameters will be
saved and enter the setting state. If there is no operation for 20s, it will automatically
return to the main interface.
Load reconnect voltage
d. Low voltage recovery operating voltage (LVR)
When the battery voltage is low, the controller stops supplying power to the load. If the
controller needs to reconnect the output, the battery voltage must be higher than the
LVD voltage or press the " " key to release. The procedure is the same as (c).
Load disconnect voltage
Long press 2S
Float voltage
Lon
g
pre
ss
5S
20S later
13
e. Low voltage disconnection voltage
When the battery voltage is low, the load output will be cut off. When the controller
detects that the battery voltage is less than the LVD point, the cut-off function will work
immediately. At the same time, the state of the controller is locked. The user must
charge the battery, when the battery voltage is higher than the LVD voltage or press the
" " key to release. The load output will return. The procedure is the same as (c).
The default data of the above three parameters a, b, c are fully considered by the
designer according to the actual usage. Users generally do not need to adjust. Please
refer to the recommendations of the battery supplier, otherwise the battery will be
damaged or irreparably damaged.
f. Load working mode selection
Control the default loading 24 hours work. When the load working time is set to 24
hours, the load will maintain a 24-hour trouble-free working state. When the load
working time is set to: s23H, it means there is a load start timer or sensor function. If the
battery capacity is sufficient, start loading at sunset. The load will work at the hour set by
the timer or stop working until sunrise.
The procedure is the same as (c).
When the load joins the timer or sensor mode, if the reset working time exceeds the
actual night time, the load output will be turned off at sunrise, although the working
time has not reached the set hour. For example, if the local actual night time is 10 hours,
the user resets the night work time to 12 hours, but the output will be automatically
turned off after 10 hours, and the remaining time will return to zero. The load of the
next sunset signal will work normally.
Load mode
g. Load sharing settings
This parameter is used to set the load discharge capacity. When the load capacity (AH)
reaches the set value, the load will automatically shut down and the set value will return
to zero. Please manually start the load or reset the consumption capacity of the load.
The default consumption capacity of the load is unlimited. The procedure is the same as
(C).
Load rationing
14
h. System voltage selection
This parameter is suitable for customers' wide-range voltage requirements. The default
display "UT0" system voltage 12/24/48v auto.
When the battery voltage is between 9V-15V, the controller automatically switches to
12V system work; when the battery voltage is between 18-30V, the controller
automatically switches to 24V system work; when the battery voltage is between 36V-
60V, the control system automatically switches to 48V operation.
If the system voltage is set to "1", the controller will always work in the 12V version.
The battery voltage is invalid. Reset data will work after reconnecting.
If the system voltage is set to "2", the controller will always work in the 24V version.
The battery voltage is invalid. Reset data will work after reconnecting.
If the system voltage is set to "3", the controller will always work in the 48V version.
The battery voltage is invalid. Reset data will work after reconnecting.
Protection function
Battery low voltage protection (LVD)
When the battery voltage is less than 11V, the LVD
protection is activated. The output is cut off and the
battery symbol and warning flash. Please increase the
charging current or charging time. When the battery
voltage is greater than 12.6V, the protection is turned
off. Load output and return or press " " on the main
interface to force unlock. 24V system is voltage x 2,48V system is voltage x 4.
Battery over voltage disconnect (OVD)
When the battery voltage is greater than 16.5V, the
overvoltage protection is activated. When the load is cut
off, the load and warning symbols flash at the same
time. When the battery voltage drops to 15V, the
protection is disconnected. The output of the load is
returned. 24V system is voltage x 2,48V system is
voltage x 4.
Overcurrent protection
When the load is short-circuited or overloaded, the
output is disconnected, and the load symbol and
warning flash. Please confirm whether the load
terminals are short- circuited and reduce the load
power. After 30s, the controller will automatically
restart to unlock, or press " "on the main interface
to force unlock.
15
High voltage disconnect protection (HVD)
When the battery is charged to 13.8V, the PWM function
is activated, the charging symbol flashes, and the
battery voltage has been limited.
24V system is voltage x2, 48V system is voltage x4.
Common faults and treatment
Failure
phenomenon
possible reason
Solution
No LCD display after
connecting with battery
Low battery voltage
Reverse battery connection
Disconnect
Please confirm the battery
voltage and connect the
controller to the battery
correctly.
The solar panel is full of
sunlight and vertical, and
there is no solar sign and
charging sign on
the LCD panel.
Solar panel connection
open circuit, short circuit
or reverse connection
Please check whether the
solar panel cable is
connected correctly and
firmly.
LVD display LVD
controller
The battery is too
discharged
Please check whether the
system design is
reasonable. If there is a
discharge capacity greater
than the charge capacity.
Controller display HVD
Battery voltage is too high
Please cut off the solar
panel first to see if the
voltage drops to a normal
level. If the fault is
not over, please cut off the
battery with the controller
and reconnect it.
Controller shows over
current protection
The load is short circuit,
overload or high peak
power
Please check whether the
load cable has a short
circuit, the power design of
the load is over-rated, and
the peak power of the load
is too high.
16
Technical Parameters
Model
PV2410U
PV2420U
PV2430U
PV2440U
PV2450U
PV2460U
PV4860U
System
voltage
12V/24V
12V/24V/48V
Maximum
input voltage
of solar panel
50V
Standby loss
50
Maximum
charging
current
10A
20A
30A
40A
50A
60A
60A
Maximum
discharge
current
10A
20A
30A
40A
50A
60A
60A
Maximum
power of
solar panel
120W/12V
240W/24V
240W/12V
480W/24V
480W/12V
960W/24V
480W/12V
960W/24V
600/12V
1200/24V
800/12V
1600/24V
800W/12V
1600W/24V
3200W/48V
Battery Low
Voltage
Protection
11.0V ADJ 9V.... 12V; x2/24V x4/48V
Battery
discharge
recovery
(LVR)
12.6V ADJ 11V.... 13.5V; x 224V; x4/48V
Float
13.8V ADJ 13V.... 15V; x224V; x4/48V
Fast charging
14.4V; x2/24V; x4/48V When the battery voltage is
Lower than 12V, start boosting and charging for 2 hours
Battery
overvoltage
protection
16.5V; x2/24V; x4/48V
Overcurrent
protection
Yes, restart every two minutes
Charging type
PWM
Temperature
compensation
-24 Mv/°C ft is 12V system; x2/24V; x4/48V
Operating
temperature
-20°C-+55°C
Terminal size
20~3 AWG 25mm2
Stripping
length
16mm
Waterproof
level
IP30
Product Size
168*92*42mm
192*109*44mm
200*127.5*55.1mm
Package Size
182*100*48mm
210*120*50mm
221*135*66mm
USB
5V 2.1A
Weight
0.3KG
0.4KG
0.7KG
Qty
40pcs
30pcs
24pcs
17
Warranty Conditions
A new product purchased in the Alza.cz sales network is guaranteed for 2 years. If you
need repair or other services during the warranty period, contact the product seller
directly, you must provide the original proof of purchase with the date of purchase.
The following are considered to be a conflict with the warranty conditions, for
which the claimed claim may not be recognized:
Using the product for any purpose other than that for which the product is intended
or failing to follow the instructions for maintenance, operation, and service of the
product.
Damage to the product by a natural disaster, the intervention of an unauthorized
person or mechanically through the fault of the buyer (e.g., during transport,
cleaning by inappropriate means, etc.).
Natural wear and aging of consumables or components during use (such as
batteries, etc.).
Exposure to adverse external influences, such as sunlight and other radiation or
electromagnetic fields, fluid intrusion, object intrusion, mains overvoltage,
electrostatic discharge voltage (including lightning), faulty supply or input voltage and
inappropriate polarity of this voltage, chemical processes such as used power
supplies, etc.
If anyone has made modifications, modifications, alterations to the design or
adaptation to change or extend the functions of the product compared to the
purchased design or use of non-original components.
18
Vážený zákazníku
Uživatelská příručka k výrobku obsahuje funkce výrobku, návod k použití a postup
obsluhy. Přečtěte si pozorně uživatelskou příručku, abyste získali co nejlepší zkušenosti a
předešli zbytečným škodám. Tuto příručku si uschovejte pro budoucí použití. Máte-li
jakékoli dotazy nebo připomínky k zařízení, obraťte se na zákaznickou linku.
www.alza.cz/kontakt
+420 225 340 111
Dovozce Alza.cz a.s. , Jankovcova 1522/53, Holešovice, 170 00 Praha 7, www.alza.cz
19
Důležité bezpečnostní upozornění
Dbejte na to, aby při připojování solárního regulátoru nedošlo ke zkratu.
Děti by si měly být vědomy nebezpečí plynoucích z elektrických zařízení. Umístěte
nabíječku na místo, kam děti nedosáhnou.
Bez ochranných opatření se nedotýkejte obnaženého vodiče na straně
stejnosměrného proudu.
Zajistěte dobré větrání, umístěte nabíječku na suché místo, neumisťujte nabíječku
do korozivního, slaného, hořlavého a výbušného prostředí, do prostředí s
vysokou teplotou, deštěm a vlhkostí.
Nepokoušejte se rozebírat nebo upravovat žádnou část, která není popsána v
této příručce. Demontáž nebo úprava tohoto výrobku může způsobit vážné
nehody. Vnitřní kontrolu, úpravy nebo opravy by měl provádět distributor tohoto
výrobku nebo kvalifikovaný servisní personál určený výrobcem.
Napětí otevřeného obvodu solárního panelu je příliš vysoké (zejména 24V a 48V
systémy), buďte opatrní.
Napájení baterie je vysoké a je zakázáno zkratovat jakýkoli vodič mezi kladnou a
zápornou elektrodou baterie. Doporučujeme přidat pojistku mezi baterii a řídicí
jednotku. (Typ “Slow motion”, provozní proud pojistky by měl být 1,5násobek
jmenovitého proudu regulátoru.)
Hlavní funkce
Automatická identifikace napětí systému, automatická identifikace 12V/24V/48V.
Humanizovaný displej LCD, rozhraní člověk-stroj, ovládání dvěma tlačítky.
Technické parametry upraveny podle přizpůsobení baterie.
Vysoce účinný a inteligentní třístupňový režim nabíjení PWM.
Lze zvolit režim řízení zátěže a resetovat funkci časovače nočního pouličního
osvětlení.
Funkce ukládání dat: zaznamenává celkovou dobu provozu systému, časovač
chyb v provozu a počet plných nabití baterie. Může se dotazovat na kapacitu
nabití a vybití.
Spolehlivá ochrana proti přepětí, zkratu, přetížení, přebití, nadměrnému vybití a
proti zpětnému připojení.
Přesná teplotní kompenzace, automatická korekce nabíjecího a vybíjecího napětí,
zvýšená životnost baterie.
Solární panely, baterie a anody solárního regulátoru nabíjení jsou spojeny
dohromady a je použit záporný sériový řídicí obvod MOSFET.
20
Doporučení
Řídicí jednotka může nastavit nabíjecí napětí podle okolní teploty tak, aby byla co
nejblíže baterii.
Systémová proudová hustota doporučeného kabelu je menší než 3A/mm2.
Snažte se použít více pramenů měděného drátu, pro pevné připojení ke svorce.
Volné silové spoje a/nebo koroze vodičů mohou způsobit odporové spoje,
roztavit izolaci vodičů, spálit okolní materiály, a dokonce způsobit požár.
Akumulátor by se měl každý měsíc plně nabít, jinak se baterie zničí.
LCD Funkce grafických symbolů
1. Výchozí noční zobrazení regulátoru: Když regulátor zjistí, že vstupní napětí
solárního panelu je nižší než napětí identifikačního bodu čidla, rozsvítí se tento
grafický symbol.
2. Výchozí denní zobrazení regulátoru: Když regulátor zjistí, že vstupní napětí
solárního panelu překračuje napětí identifikačního bodu čidla, rozsvítí se tento
grafický symbol.
3. Indikace parametrů fotovoltaického pole: Tento grafický symbol se zobrazuje při
zobrazení údajů o solárním panelu. Například napětí solárních panelů.
4. Indikace parametrů baterie: Při zobrazení parametru baterie se zobrazí tento
grafický symbol. Například napětí baterie, teplota baterie.
5. Indikace parametrů zatížení: Při zobrazení parametru zatížení se zobrazí tento
grafický symbol.
6. Systémové napětí: Pokud se na LCD displeji zobrazí různá systémová napětí,
regulátor automaticky upraví technické parametry.
7. Oblast číselného zobrazení.
8. Funkce nastavení časovače.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79

BYGD Solar Charger Controller Používateľská príručka

Typ
Používateľská príručka