Návod k montáži /
Mounting instructions
Probe DCL with Modbus RTU interface RS485
Probe LMK/LMP
Combined level, conductivity and temperature probe
DCL 531, DCL 551, DCL 571, LMK 306, LMK 307,
LMK 307T, LMK 309, LMK 358, LMK 358H, LMK 382,
LMK 382H, LMK 387, LMK 387H, LMK 806, LMK 807,
LMK 808, LMK 809, LMK 858, LMP 305, LMP 307,
LMP 307i, LMP 307T, LMP 308, LMP 308i, LMP 808
LCT 307i RS485
Centrála východní Evropa
Headquarters Ostern Europe
BD SENSORS s.r.o.
Hradišťská 817
CZ - 687 08 Buchlovice
Česká republika / Czech Republic
Tel.: +420 572 411 011
Fax: +420 572 411 497
Centrála /
Headquarters
BD SENSORS GmbH
BD-Sensors-Str. 1
D - 95199 Thierstein
Německo /
Germany
Tel.: +49 (0) 92 35 / 98 11-0
Fax: +49 (0) 92 35 / 98 11-11
Rusko /
Russia
BD SENSORS RUS
39a, Varshavskoe shosse
RU - Moscow 117105
Rusko /
Russia
Tel.: +7 (0) 9 59 81 / 09 63
Fax: +7 (0) 9 57 95 / 07 21
Tento návod k montáži je výtah z podrobného
návodu k obsluze. Ten si prosím stáhněte
z našich internetových stránek, pokud nejste
s výrobkem dobře seznámeni.
These mounting instructions are an excerpt from the complete
operating manual. It may be downloaded from our homepage,
if you are not familiar with the device.
www.bdsensors.cz
www.bdsensors.com
– Technické změny vyhrazeny –
– Technical modifications reserved –
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
be performed by qualified technical personnel.
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on
occupational safety, accident prevention as well as national
installation standards and approved engineering
techniques must in addition be complied with.
WARNING! Before the installation: make sure that the
inside of the threaded neck of the closed valve is clean. If
need, remove the residual liquid in a proper way. Do not
mount the device against the liquid inside the thread
connection.
Limitation of liability
If the instructions in the mounting instructions /operating
manual are not adhered to or if the device is inappropriately
used, modified or damaged, liability is not assumed and
warranty claims will be excluded.
Intended use
Ensure that the medium is compatible with the media-
wetted parts and that the device is suitable for the
application without restrictions. The technical data listed in
the current data sheet is binding.
Product identification
Mounting
- Carefully remove the pressure measuring device from the
package and dispose of the package properly.
- Mount the device according to your demands.
- Flange version has to be tightened by an open-end wrench.
(approx. 25 Nm).
Usually, the probe has been delivered without mounting
accessories. For different mounting demands,
BD SENSORS offers as accessories mounting clamps,
terminal clamps and mounting flanges.
Pin configuration
Electrical connections cable colours
Supply
Supply −
Signal + (only 3-wire)
wh (white)
bn (brown)
gn (green)
Shield gnye (green yellow)
LMK 307T and LMP307T cable colours
Supply P+
Supply P–
Supply T+
Supply T–
wh (white)
bn (brown)
gy (gray)
pk (pink)
Shield gnye (green yellow)
DCL 531, DCl 551, DCL 571 cable colours
Supply +
Supply –
A +
B –
DCL 531: Reset
wh (white)
bn (brown)
gn (green)
ye (yellow)
pk (pink)
Shield
LCT 307i RS485 Cable colours
Supply + wh (white)
Supply - bn (brown)
A + ye (yellow)
B - pk (pink)
Wiring diagrams
2-wire-system (current)
2-wire-system (current) HART
2x2-wire-system (current) (LMK 307T / LMP 307T)
3-wire-system (current/supply)
RS 485 / Modbus RTU; RS485/ Modbus RTU with reset function
Gauge/relative devices are equipped with cable with
integrated air tube for atmospheric pressure reference.
Install cable end in a control cabinet or suitable terminal
box in dry area which is free of aggressive gasses to avoid
damages.
For the electrical connection a shielded and twisted
multicore cable is recommended.
Removing the protection cap (if necessary)
If the device shall be used in high-viscosity media, a careful
removal of the cap before start-up is necessary (if existing).
To prevent a damage of the diaphragm, please follow these
instructions.
Removal by hand
- Hold the probe in a way that the protection cap points
upwards.
- Hold the probe with one hand on the sensor section (1).
- Remove the protection cap (2) with the other hand.
Removal with a tool (recommended)
- Hold the probe in a way that the protection cap points
upwards.
- Slide a small tool such as a screwdriver (8) straight through
two opposite drill holes in the protective cap (2).
- Lever it off by moving up the handle of the screwdriver.
Make sure that the sensor (7) under the protection cap will
not be damaged!
Separability
(with LMK 358, LMK 358H, LMK 808, LMK 858,
LMP 308, LMP 308i and LMP 808), LCT 307i RS 485
In order to facilitate stock keeping and maintenance, the probe
head is plugged to the cable assembly
with a connector and can be easily
changed.
Disassembly
- Hold the probe on the sensor
section (2) with one hand and turn
the nut (4) carefully to the left with
the other hand. Prevent torsion of
the cable section (3) against the
housing!
- While screwing and pulling off the
sensor section (2) from the cable
section (3), hold it straight to
prevent damages on the plugs.
Assembly
- Check the o-rings (5, 6) and exchange damaged o-rings if
necessary.
- Lubricate the radial o-rings (5) with Vaseline or o-ring
grease.
- Remove any grease residue from the axial-o-ring (6).
- Plug the cable section (3) straight into the plug of the
sensor section (2).
- Hold the probe onto the sensor section (2) with one hand.
Screw on and tighten the nut (4) carefully with the other
hand. Prevent torsion of the cable section (3) against the
housing!
Pin configuration of plug
Electrical
connections Binder series 723
(5-pin) Binder series 723
(7-pin)
Supply
Supply −
3
1 3
1
Shield
5 2
Supply
Supply −
Signal +
3
4
1
3
1
6
Shield
5 2
RxD
TxD
GND
-
-
-
4
5
7
signal +
VS
I/U
supply –
LCT