EKOM DK50 2V/50 Používateľská príručka

Typ
Používateľská príručka

Tento návod je vhodný aj pre

DK50 2V/50/M
DK50 2x2V/110/M
USER MANUAL
EN
BENUTZERHANDBUCH
DE
MANUEL DE L’UTILISATEUR
FR
РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ
RU
INSTRUKCJA OBSŁUGI
PL
NÁVOD NA POUŽITIE
SK
NÁVOD K POUŽITÍ
CS
COMPRESSOR
KOMPRESSOR
COMPRESSEUR
КОМПРЕССОР
SPRĘŻARKA
KOMPRESOR
DK50 2V/50
DK50 2x2V/110
EKOM spol. s r. o.
Priemyselná 5031/18
SK-921 01 Piešťany
Slovak Republic
tel.: +421 33 7967255
fax: +421 33 7967223
www.ekom.sk
email: ekom@ekom.sk
DATE OF LAST REVISION
DATUM DER LETZTEN ÜBERARBEITUNG
DATE DE LA DERNIÈRE RÉVISION
ДАТА ПОСЛЕДНЕЙ РЕДАКЦИИ
DATA OSTATNIEJ AKTUALIZACJI
DÁTUM POSLEDNEJ REVÍZIE
DATUM POSLEDNÍ REVIZE
11/2023
NP-DK50 2V 50, 2x2V 110-AD-
8_11-2023
112000570-000
CONTENTS
11/2023 5 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
CONTENTS
IMPORTANT INFORMATION ........................................................................................................ 6
1. CONFORMITY WITH THE REQUIREMENTS OF EUROPEAN UNION DIRECTIVES .... 6
2. INTENDED USE .............................................................................................................. 6
3. CONTRAINDICATIONS AND SIDE-EFFECTS ................................................................ 6
4. SYMBOLS ........................................................................................................................ 6
5. WARNINGS ..................................................................................................................... 7
6. STORAGE AND TRANSPORT CONDITIONS ................................................................. 9
PRODUCT DESCRIPTION .......................................................................................................... 10
7. VARIANTS ..................................................................................................................... 10
8. ACCESSORIES ............................................................................................................. 11
9. PRODUCT FUNCTION .................................................................................................. 12
TECHNICAL DATA ...................................................................................................................... 19
INSTALLATION ........................................................................................................................... 31
10. INSTALLATION CONDITIONS ...................................................................................... 31
11. COMPRESSOR ASSEMBLY ......................................................................................... 31
12. PNEUMATIC CONNECTION ......................................................................................... 36
13. ELECTRICAL CONNECTION ........................................................................................ 38
14. PLACEMENT OF THE COMPRESSOR IN THE CABINET ............................................ 39
15. COMMISSIONING ......................................................................................................... 44
16. PNEUMATIC AND ELECTRICAL DIAGRAMS ............................................................... 46
OPERATION ................................................................................................................................ 52
17. SWITCHING ON THE COMPRESSOR .......................................................................... 53
18. SWITCHING OFF THE COMPRESSOR ........................................................................ 53
AD DRYER .................................................................................................................................. 54
19. PRINCIPLE OF OPERATION ........................................................................................ 54
20. USER INTERFACE/SETTINGS ..................................................................................... 55
21. MAIN SCREENS ............................................................................................................ 57
22. INDICATION OF MAINTENANCE AND ALARM STATES.............................................. 60
PRODUCT MAINTENANCE ........................................................................................................ 63
23. PRODUCT MAINTENANCE ........................................................................................... 63
24. LONG-TERM SHUTDOWN ............................................................................................ 72
25. DISPOSAL OF DEVICE ................................................................................................. 72
TROUBLESHOOTING ................................................................................................................. 73
26. REPAIR SERVICE ......................................................................................................... 75
ANNEX ...................................................................................................................................... 504
27. INSTALLATION RECORD ........................................................................................... 504
IMPORTANT INFORMATION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 6 11/2023
IMPORTANT INFORMATION
1. CONFORMITY WITH THE REQUIREMENTS OF EUROPEAN UNION DIRECTIVES
This product conforms to the requirements of the Regulation (EU) on medical devices (MDR
2017/745) and is safe for the intended use if all safety instructions are followed.
2. INTENDED USE
The compressor is used as a source of clean, oil-free compressed air to power active medical
devices where the parameters and properties of the compressed air are suitable for the specific
application.
Compressed air supplied by the compressor is unsuitable for use with artificial
lung ventilation devices without further filtration
Any other use of the product beyond its intended use is considered an incorrect use. The
manufacturer is not liable for any damages or injuries resulting from the incorrect use.
3. CONTRAINDICATIONS AND SIDE-EFFECTS
There are no contraindications or side-effects known.
4. SYMBOLS
The following symbols and marks are used in the User manual, on the device and its packaging:
General warning
Warning - risk of electric shock
Warning - compressor is controlled automatically
Warning - hot surface
General caution
Read the operating instructions
Refer to instruction manual
CE marking
Medical device
Serial number
Article number
IMPORTANT INFORMATION
11/2023 7 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
Unique Device Identifier
Swiss Authorised Representative
Swiss Importer
Protecting earthing
Fuse
Package handling label fragile
Package handling label this side up
Package handling label keep dry
Package handling label temperature limits
Package handling label limited stacking
Package label recyclable material
Manufacturer
5. WARNINGS
The product is designed and manufactured to be safe for the user and the surrounding environment
when used in the defined manner. Keep the following warnings in mind.
5.1. General warnings
READ THE USER MANUAL CAREFULLY BEFORE USING THE DEVICE AND KEEP IT FOR
FUTURE USE!
The user manual supports the correct installation, operation and maintenance of the product.
Careful review of this manual will provide the information necessary for the correct operation of
the product for its intended use.
Original packaging should be retained for the return of the device. Only the original packaging
ensures protection of the device during transport. If it is necessary to return the product during
the warranty period, the manufacturer is not liable for damages caused by improper packaging.
This warranty does not cover damages originating from the use of accessories other than those
specified or recommended by the manufacturer.
The manufacturer only guarantees the safety, reliability and function of the device if:
- installation, new settings, changes, expansion, and repairs are performed by the
manufacturer or an organisation authorised by the manufacturer
IMPORTANT INFORMATION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 8 11/2023
- the product is used pursuant to the user manual
The user manual corresponds to the configuration of the product and its compliance with the
applicable safety and technical standards at the time of printing. The manufacturer reserves all
rights for the protection of its configuration, methods and names.
Translation of the user manual is performed in accordance with the best available knowledge.
The Slovak version is to be used in the event of any uncertainties.
This user manual is the original instructions. Translation is performed in accordance with the best
available knowledge.
5.2. General safety warnings
The manufacturer designed and manufactured the product to minimise all risks when used correctly
for the intended use. The manufacturer considers it its obligation to lay down the following general
safety precautions.
Use and operation of the product must comply with all laws and local regulations valid in the
place of use. The operator and user are responsible for following all the appropriate regulations
in the interests of performing work safely.
Only the use of original parts guarantees the safety of operating personnel and the flawless
operation of the product itself. Only the accessories and parts mentioned in the technical
documentation or expressly approved by the manufacturer should be used.
The operator must ensure that the device is functioning correctly and safely before every use.
The user must be familiar with the operation of the device.
Do not use the product in environments with a risk of explosion.
The user must inform the supplier immediately if any problem directly related to the operation of
the device occurs.
Any serious incident that has occurred in relation to the device should be reported to the
manufacturer and the competent authority of the Member State in which the user and / or patient
is established.
5.3. Safety warnings on protection from electric current
The device must only be connected to a properly installed, earthed socket.
Before the product is plugged in, ensure that the mains voltage and frequency stated on the
product are in compliance with the values of the mains.
Prior to putting the device into operation check for any damage to the connected pneumatic lines
and electrical wiring. Replace damaged pneumatic lines and electrical wirings immediately.
Immediately disconnect the product from the mains (remove power cord from the socket) in
hazardous situations or in the case of a technical malfunction.
During all repairs and maintenance, ensure that:
- the mains plug is removed from the power socket
- pressure is vented from the air tank and pipes
The product shall only be installed by a qualified technician.
IMPORTANT INFORMATION
11/2023 9 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
6. STORAGE AND TRANSPORT CONDITIONS
The compressor is shipped from the manufacturer in transport packaging. This protects the product
from damage during transport.
Potential for damage to pneumatic components.
The compressor must be transported only when all air has been vented. Before
moving or transporting the compressor, release all the air pressure from the tank
and pressure hoses and drain condensate from the tank and from the condensate
separator on the dryer.
Keep the original factory packaging in case the device needs to be returned Use
the original factory packaging during transport as it provides optimum protection
for the product. . If it is necessary to return the product during the warranty
period, the manufacturer is not liable for damages caused by improper
packaging.
The compressor is shipped in a vertical position and must be secured using
transport straps.
Protect the compressor from humid and dirty environments and extreme temperatures
during transport and storage. Do not store near any volatile chemical substances.
If not, please dispose of the original packaging material in an environmentally-friendly
way. The packaging cardboard can be recycled with old paper.
6.1. Ambient conditions
Products may only be stored and transported in vehicles that are free of any traces of volatile
chemicals under the following climactic conditions:
Temperature
–25°C to +55°C
Relative humidity
max. 90% (non-condensing)
Storing or shipping the equipment in any conditions other than those specified below is
prohibited.
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 10 11/2023
PRODUCT DESCRIPTION
7. VARIANTS
The compressor is manufactured according to its intended application in the following variants:
DK50 2V/50/M
Compressor with adsorption dryer
DK50 2V/50S/M
Compressor in cabinet with adsorption dryer
Cabinet S50
It decreases noise level of the compressor
DK50 2x2V/110/M
Compressor with adsorption dryer
DK50 2x2V/110S/M
Compressor in cabinet with adsorption dryer
Cabinet S110
It decreases noise level of the compressor
DK50 2V/50/M
S50
DK50 2V/50S/M
DK50 2x2V/110/M
S110
DK50 2x2V/110S/M
PRODUCT DESCRIPTION
11/2023 11 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
8. ACCESSORIES
Accessories that are not included in the standard order must be ordered separately.
Set of compressed air outlet filters
The compressor may be equipped with a set of filters if specified. The filter set may be equipped
with an air pressure regulator.
Where a different level of air filtration is required, this requirement must be
agreed upon with the supplier and specified in the order.
Type
Use
Level of filtration
(µm)
Article number
FS 30F
DK50 2V/50/M
DK50 2x2V/110/M
1
604014119-014
FS 30M
1+0.1
604014119-015
FS 30S
1+0.01
604014119-017
FS 30A
1 + 0.01 + A**
604014119-018*
*) submicrofilter with activated carbon
*) - set FS 30A, in the standard configuration, this cannot be combined with a pressure regulator on
products DK50 2V/50/M; please contact your supplier if you are interested in such set (with a
regulator)
Filter set regulator assembly
The compressor may be equipped with a pressure regulator of the compressed air outlet if specified.
The regulator must be selected according to the application to the filter set, or separately The
regulator shall ensure constant pressure at the outlet.
Type
Use
Article number
Regulator complete
(to the filter assembly)
DK50 2V/50/M
DK50 2x2V/110/M
604014130-000
REG12 (separate)
DK50 2V/50/M
447000001-088
REG13 (separate)
DK50 2x2V/110/M
447000001-096
Filter set brackets
A suitable bracket must be ordered for every filter set.
3KOM modules for controlling multiple compressors in Master-Slave functionality
A 3KOM control module may be ordered to manage the operation of 2 or 3 identical compressors
with the same pressure range in Master-Slave functionality. In use, the controller in the module
takes over the compressor switching function. The control module may be ordered in the
configurations shown in the following table.
Type
Use
Article number
Compressor-mounted bracket
DK50 2V/50/M
603014177-000
DK50 2x2V/110/M
604014169-000
DK50 2x2V/110/M
to order
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 12 11/2023
Compressor model
Control schematic
Article number
System air outlet
DK50 2V/50/M
DK50 2x2V/110/M
1+1
1+1+1
603002152-000
G 3/4“
Equipotential bonding socket
The socket provides protective bonding.
Type
Use
Name
Article no.
POAG-KBT6-EC
DK50 2V/50S/
DK50 2x2V/110S/M
Mains plug
connector
033400075-000
FLEXI-S/POAG-HK6
Conductor (1 m)
034110083-000
9. PRODUCT FUNCTION
9.1. Compressor with adsorption dryer
(Fig. 1, Fig. 2) The air pump (1) draws in air through the inlet filter (8) and supplies compressed air
through the connecting hose into the adsorption dryer (13). From the inlet to the dryer module, the
air is first cooled in the integrated cooler (30) and then moves through the condensate separator
(37), entering the active chamber with adsorbent (32), where the air is dried. A portion of the air is
fed into the second, regenerated chamber, where this air is used to remove moisture from the
adsorbent, after which it is vented to the atmosphere. The active chamber switches on a cyclical
basis. The dry air then passes through the non-return valve (3) into the air tank (2). Air drying
efficiency (the pressure dew point) is determined by the dew point sensor (15) located in the air
tank.
9.2. Compressor cabinet
(Fig. 4) The soundproof cabinet provides compact covering of the compressor, dampens noise
efficiently, providing sufficient exchange of cooling air. With its design It can be placed in a dentist’s
office as a part of furniture. The fan (9) under the compressor pump provides cooling of the
compressor. It is in operation at the same time with the compressor motor or after switching on the
temperature switch at temperature above 40°C. After cooling the cabinet area approximately under
32°C, the fan turns off automatically. The dryer display (25) is located on the front panel of the
cabinet.
Risk of compressor overheating.
Make sure that there are no obstacles at the cooling air inlet into the cabinet
(around the bottom part of the cabinet) and at the hot air outlet on the top back
side of the cabinet.
If the compressor is placed on a soft floor, e.g. carpet, create space between the
base and the floor or the cabinet and the floor, e.g. underlay the footings with
hard pads to ensure sufficient cooling of the compressor.
PRODUCT DESCRIPTION
11/2023 13 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
Descriptions for figures 1 - 3
1 Air pump
2 Air tank
3 Non-return valve
4 Pressure switch
5 Safety valve
6 Pressure gauge
7 Drain valve
8 Inlet filter
9 Compressor fan
10 Casters
11 Hour counter
12 Electrical box
13 AD dryer
14 Air outlet
15 Pressure dew point sensor
16 Condensate collection vessel
17 Supporting bracket
18 Cabinet fan
19 Cabinet pressure gauge
20 Switch
21 Cabinet connector
22 Pressure gauge hose
23 Wall stop
24 Pulling system
25 Cabinet display
26 Handle
27 Cabinet gas springs
28 *Dryer display
29 Outlet module
30 Cooling module
31 Electrical panel
32 Dryer chamber
33 Inlet valve module
34 Compressed air inlet
35 Regeneration solenoid valve
36 Dryer fan
37 Condensate separator
38 Condensate drain solenoid valve
39 Air outlet
40 **Bushing
41 Outlet from condensate separator and
regeneration valves
42 Power cord
* Position (28) applies to the DK50 2V/50/M, DK50 2x2V/110/M model without the cabinet,
position (28) in the case of the DK50 2V/50 S/M, DK50 2x2V/110 S/M with the cabinet is a simple
cover.
** For the cabinet model, the cable connected to the display (25) in the front panel of the cabinet
is routed through the universal bushing (40).
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 14 11/2023
Fig. 1: DK50 2V/50/M Compressor with adsorption dryer
PRODUCT DESCRIPTION
11/2023 15 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
Fig. 2: DK50 2x2V/110/M Compressor with adsorption dryer
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 16 11/2023
Fig. 3:Adsorption dryer
ADM 140/50
ADM 280/110
* Position (28) applies to the DK50 2V/50/M, DK50 2x2V/110/M model without the cabinet;
position (28) in the case of the DK50 2V/50 S/M, DK50 2x2V/110 S/M with the cabinet is a simple
cover.
** For the cabinet model, the cable connected to the display (25) in the front panel of the cabinet
is routed through the universal bushing (40).
PRODUCT DESCRIPTION
11/2023 17 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
Fig. 4: Cabinet
A - DK50 2V/50S/M
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 18 11/2023
B - DK50 2x2V/110S/M
TECHNICAL DATA
11/2023 19 NP-DK50 2V 50, 2x2V 110-AD-8_11-2023
TECHNICAL DATA
Compressors are designed for operation in dry, ventilated and dust-free indoor rooms under the
following climactic conditions:
Temperature
+5°C to +40°C
Relative humidity
max. 70%
Working pressure 6 8 bar
DK50 2V/50/M
DK50 2V/50S/M
Rated voltage
Frequency a)
V, Hz
230, 50
3x400, 50
230, 50
3x400, 50
Capacity at 6 bar (FAD) -20°C
l/min
120
120
Working pressure b)
bar
6.0 8.0
6.0 8.0
Rated current
A
8.8
3.9
9.0
4.1
Motor power
kW
1.2
1.2
Air tank volume
l
50
50
Air quality - filtration
m
-
-
Maximum operating pressure of safety
valve
bar
9.0
9.0
Noise level at 5 bar (LpA)
dB
70.5
52.0
Operating mode
%
S1-100
S1-100
PDP drying performance at 7 bar d)
°C
-20
-20
Dryer low pressure alarm
bar
< 3
< 3
Dryer high pressure alarm
bar
˃ 9
˃ 9
Dryer high dew point alarm
°C
˃ -20
˃ -20
Time to fill air tank from 0 to 7 bar
s
185
185
Dimensions (net)
w x d x h
mm
580x600x805
750x715x1015
Net weight c)
kg
74
72
125
123
Classification under EN 60601-1
Class I.
a) Specify the compressor version when ordering
b) Consult any other range of pressure with the supplier
c) Weight is indicative and only applies to the product without accessories
d) Applies to ambient temperatures of <30°C PDP pressure dew point
TECHNICAL DATA
NP-DK50 2V 50, 2x2V 110-AD-8_11-2023 20 11/2023
Dependence of compressor output on working pressure
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462
  • Page 463 463
  • Page 464 464
  • Page 465 465
  • Page 466 466
  • Page 467 467
  • Page 468 468
  • Page 469 469
  • Page 470 470
  • Page 471 471
  • Page 472 472
  • Page 473 473
  • Page 474 474
  • Page 475 475
  • Page 476 476
  • Page 477 477
  • Page 478 478
  • Page 479 479
  • Page 480 480
  • Page 481 481
  • Page 482 482
  • Page 483 483
  • Page 484 484
  • Page 485 485
  • Page 486 486
  • Page 487 487
  • Page 488 488
  • Page 489 489
  • Page 490 490
  • Page 491 491
  • Page 492 492
  • Page 493 493
  • Page 494 494
  • Page 495 495
  • Page 496 496
  • Page 497 497
  • Page 498 498
  • Page 499 499
  • Page 500 500
  • Page 501 501
  • Page 502 502
  • Page 503 503
  • Page 504 504
  • Page 505 505
  • Page 506 506
  • Page 507 507
  • Page 508 508
  • Page 509 509
  • Page 510 510
  • Page 511 511
  • Page 512 512

EKOM DK50 2V/50 Používateľská príručka

Typ
Používateľská príručka
Tento návod je vhodný aj pre