EKOM DK50 2V/50 Používateľská príručka

Kategória
Vzduchové kompresory
Typ
Používateľská príručka

Tento návod je vhodný aj pre

DK50 2V/50/M
DK50 2x2V/110/M
NÁVOD NA POUŽITIE
SK
USER MANUAL
EN
BENUTZERHANDBUCH
DE
COMPRESSOR
KOMPRESSOR
KOMPRESOR
DK50 2V/50
DK50 2x2V/110
EKOM spol. s r. o.
Priemyselná 5031/18
SK-921 01 Piešťany
Slovak Republic
tel.: +421 33 7967255
fax: +421 33 7967223
www.ekom.sk
email: ekom@ekom.sk
DATE OF LAST REVISION
DATUM DER LETZTEN ÜBERARBEITUNG
DÁTUM POSLEDNEJ REVÍZIE
11/2023
NP-DK50 2V 50, 2x2V 110-AD-
A-8_11-2023
112000519-000
CONTENTS ................................................................................................. 5
INHALT ........................................................................................................ 74
OBSAH ........................................................................................................ 143
CONTENTS
11/2023 5 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
CONTENTS
GENERAL INFORMATION ............................................................................................................ 6
1. CONFORMITY WITH THE REQUIREMENTS OF THE EUROPEAN UNION ................... 6
2. SYMBOLS ........................................................................................................................ 6
3. DEVICE USE ................................................................................................................... 7
4. GENERAL SAFETY INSTRUCTIONS .............................................................................. 8
5. STORAGE AND TRANSPORT CONDITIONS ................................................................. 9
PRODUCT DESCRIPTION .......................................................................................................... 10
6. VARIANTS ..................................................................................................................... 10
7. ACCESSORIES ............................................................................................................. 11
8. PRODUCT FUNCTION .................................................................................................. 12
TECHNICAL DATA ...................................................................................................................... 19
INSTALLATION ........................................................................................................................... 29
9. INSTALLATION CONDITIONS ...................................................................................... 29
10. COMPRESSOR ASSEMBLY ......................................................................................... 29
11. PNEUMATIC CONNECTION ......................................................................................... 34
12. ELECTRICAL CONNECTION ........................................................................................ 36
13. PLACEMENT OF THE COMPRESSOR IN THE CABINET ............................................ 37
14. COMMISSIONING ......................................................................................................... 43
15. PNEUMATIC AND ELECTRICAL DIAGRAMS ............................................................... 44
OPERATION ................................................................................................................................ 50
16. SWITCHING ON THE COMPRESSOR .......................................................................... 51
17. SWITCHING OFF THE COMPRESSOR ........................................................................ 51
AD DRYER .................................................................................................................................. 52
18. PRINCIPLE OF OPERATION ........................................................................................ 52
19. USER INTERFACE/SETTINGS ..................................................................................... 53
20. MAIN SCREENS ............................................................................................................ 55
21. INDICATION OF MAINTENANCE AND ALARM STATES.............................................. 58
PRODUCT MAINTENANCE ........................................................................................................ 61
22. PRODUCT MAINTENANCE ........................................................................................... 61
23. LONG-TERM SHUTDOWN ............................................................................................ 70
24. DISPOSAL OF DEVICE ................................................................................................. 70
TROUBLESHOOTING ................................................................................................................. 71
25. REPAIR SERVICE ......................................................................................................... 73
ANNEX ...................................................................................................................................... 211
26. INSTALLATION RECORD ........................................................................................... 211
GENERAL INFORMATION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 6 11/2023
GENERAL INFORMATION
Carefully read this user manual before using the product and carefully store it for future reference.
The user manual aids in the proper use, including installation, operation and maintenance, of the
product.
The user manual corresponds to the configuration of the product and its compliance with
applicable safety and technical standards at the time of its printing. The manufacturer reserves all
rights for the protection of its configuration, processes and names.
The Slovak version represents the original version of the user manual. The translation of the user
manual is performed in accordance with the best available knowledge. The Slovak version is to be
used in the event of any uncertainties.
The user manual is original and the translation is performed with the best available knowledge.
1. CONFORMITY WITH THE REQUIREMENTS OF THE EUROPEAN UNION
This product conforms to the requirements of the European Union 2006/42/EC, 2014/29/EU,
2014/35/EU, 2014/30/EU, 2011/65/EU and is safe if used in compliance with the intended use and
if all safety instructions are followed.
User manual is in compliance with requirements of Directive 2006/42/EC.
2. SYMBOLS
The following symbols and marks are used in the User manual, on the device and its packaging:
General warning
Warning - risk of electric shock
Warning - compressor is controlled automatically
Warning - hot surface
General caution
Read the operating instructions
Refer to instruction manual
CE marking
Serial number
Article number
Protecting earthing
GENERAL INFORMATION
11/2023 7 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
Fuse
Package handling label fragile
Package handling label this side up
Package handling label keep dry
Package handling label temperature limits
Package handling label limited stacking
Package label recyclable material
Manufacturer
3. DEVICE USE
3.1. Intended use
The compressor is used as source of clean oil-free compressed air intended to be used in industry
and laboratories, where parameters and properties of the compressed air are suitable.
The compressor is exclusively intended to compress air without content of explosive or chemically
unstable substances.
The compressor is intended for operation in clean and dry rooms.
3.2. Incorrect use
Contamination risk.
Air from the compressor is without additional treatment not suitable for
breathing and direct contact with food
Explosion risk.
The product is not intended for operation in rooms with explosion risk.
The compressor must not be used to compress aggressive gases.
The compressor must not be operated in premises with occurrence of flammable vapors.
The compressor must not be operated in other conditions as mentioned in Technical data.
Any other use of the product beyond the intended use is considered as incorrect use. The
manufacturer is not responsible for any damages or injuries as a result of incorrect use or
disobedience to instructions stated in this User manual. All risks shall be solely borne by the
user/operator.
GENERAL INFORMATION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 8 11/2023
4. GENERAL SAFETY INSTRUCTIONS
The product is designed and manufactured so that any risks connected with its use are minimized
and the product is safe for the user and surrounding when used according to the intended use and
the instructions stated below are followed.
4.1. Required qualification of the personnel
Each user must be trained by the manufacturer or an organization authorized by the
manufacturer or instructed on the device operation by other trained user.
Installation, new settings, changes, extensions and repairs of the product may be performed by
the manufacturer or an organization authorized by the manufacturer (hereinafter qualified
technician).
- Otherwise the manufacturer is not responsible for safety, reliability and correct functioning
of the product.
4.2. General instructions
When operating the compressor, all acts and local regulations valid in the place of use must be
observed. The operator and user are responsible for following the applicable regulations.
Before every use, the user must check, if the device is functioning correctly and safely. Before
building the compressor in other devices, the supplier must assess, if the supplied air and
construction of the device comply with the requirements of the specified intended use. Taking
this into account, follow the product technical data. Assessment of conformity shall be
performed by the manufacturer supplier of the final product.
4.3. Protection from dangerous voltage and pressure
The equipment may only be connected to a properly installed socket connected to earth
(grounded).
Before the product is plugged in, make sure that the mains voltage and frequency stated on the
product are the same as the power mains.
Check for any damage to the connected compressed air system and electrical circuits before
use. Replace damaged pneumatic and electrical conductors immediately.
Immediately disconnect the product from the mains (remove the power cord from the socket) in
hazardous situations or when a technical malfunction occurs.
Never adjust or use the safety valve to release the air pressure in the air tank.
Never adjust or use pressure relief valves to release air pressure from the device.
4.4. Original spare parts and accessories
Only the use of original parts guarantees the safety of operating personnel and flawless
operation of the product itself. Only accessories and replacement parts specified in the
technical documentation or expressly approved by the manufacturer may be used.
The warranty does not cover damage resulting from the use of other accessories and
replacement parts as specified or recommended by the manufacturer and the manufacturer has
no related liability.
GENERAL INFORMATION
11/2023 9 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
5. STORAGE AND TRANSPORT CONDITIONS
The compressor is shipped from the manufacturer in transport packaging. This protects the
product from damage during transport.
Potential for damage to pneumatic components.
The compressor must be transported only when all air has been vented. Before
moving or transporting the compressor, release all the air pressure from the tank
and pressure hoses and drain condensate from the tank and from the condensate
separator on the dryer.
Keep the original factory packaging in case the device needs to be returned Use
the original factory packaging during transport as it provides optimum protection
for the product. . If it is necessary to return the product during the warranty
period, the manufacturer is not liable for damages caused by improper
packaging.
The compressor is shipped in a vertical position and must be secured using
transport straps.
Protect the compressor from humid and dirty environments and extreme temperatures
during transport and storage. Do not store near any volatile chemical substances.
If not, please dispose of the original packaging material in an environmentally-friendly
way. The packaging cardboard can be recycled with old paper.
5.1. Ambient conditions
Products may only be stored and transported in vehicles that are free of any traces of volatile
chemicals under the following climactic conditions:
Temperature
–25°C to +55°C
Relative humidity
max. 90% (non-condensing)
Storing or shipping the equipment in any conditions other than those specified below is
prohibited.
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 10 11/2023
PRODUCT DESCRIPTION
6. VARIANTS
The compressor is manufactured according to its intended application in the following variants:
DK50 2V/50/M
Compressor with adsorption dryer
DK50 2V/50S/M
Compressor in cabinet with adsorption dryer
Cabinet S50
It decreases noise level of the compressor
DK50 2x2V/110/M
Compressor with adsorption dryer
DK50 2x2V/110S/M
Compressor in cabinet with adsorption dryer
Cabinet S110
It decreases noise level of the compressor
DK50 2V/50/M
S50
DK50 2V/50S/M
DK50 2x2V/110/M
S110
DK50 2x2V/110S/M
PRODUCT DESCRIPTION
11/2023 11 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
7. ACCESSORIES
Accessories that are not included in the standard order must be ordered separately.
Set of compressed air outlet filters
The compressor may be equipped with a set of filters if specified. The filter set may be equipped
with an air pressure regulator.
Where a different level of air filtration is required, this requirement must be
agreed upon with the supplier and specified in the order.
Type
Use
Level of filtration (µm)
Article number
FS 30F
DK50 2V/50/M
DK50 2x2V/110/M
1
604014119-014
FS 30M
1+0.1
604014119-015
FS 30S
1+0.01
604014119-017
FS 30A
1 + 0.01 + A**
604014119-018*
*) submicrofilter with activated carbon
*) - set FS 30A, in the standard configuration, this cannot be combined with a pressure regulator
on products DK50 2V/50/M; please contact your supplier if you are interested in such set (with a
regulator)
Filter set regulator assembly
The compressor may be equipped with a pressure regulator of the compressed air outlet if
specified. The regulator must be selected according to the application to the filter set, or
separately The regulator shall ensure constant pressure at the outlet.
Type
Use
Article number
Regulator complete
(to the filter assembly)
DK50 2V/50/M
DK50 2x2V/110/M
604014130-000
REG12 (separate)
DK50 2V/50/M
447000001-088
REG13 (separate)
DK50 2x2V/110/M
447000001-096
Filter set brackets
A suitable bracket must be ordered for every filter set.
3KOM modules for controlling multiple compressors in Master-Slave functionality
A 3KOM control module may be ordered to manage the operation of 2 or 3 identical compressors
with the same pressure range in Master-Slave functionality. In use, the controller in the module
takes over the compressor switching function. The control module may be ordered in the
configurations shown in the following table.
Type
Use
Article number
Compressor-mounted bracket
DK50 2V/50/M
603014177-000
DK50 2x2V/110/M
604014169-000
DK50 2x2V/110/M
to order
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 12 11/2023
Compressor model
Control schematic
Article number
System air outlet
DK50 2V/50/M
DK50 2x2V/110/M
1+1
1+1+1
603002152-000
G 3/4“
Equipotential bonding socket
The socket provides protective bonding.
Type
Use
Name
Article number
POAG-KBT6-EC
DK50 2V/50S/
DK50 2x2V/110S/M
Mains plug
connector
033400075-000
FLEXI-S/POAG-HK6
Conductor (1 m)
034110083-000
8. PRODUCT FUNCTION
8.1. Compressor with adsorption dryer
(Fig. 1, Fig. 2) The air pump (1) draws in air through the inlet filter (8) and supplies compressed air
through the connecting hose into the adsorption dryer (13). From the inlet to the dryer module, the
air is first cooled in the integrated cooler (30) and then moves through the condensate separator
(37), entering the active chamber with adsorbent (32), where the air is dried. A portion of the air is
fed into the second, regenerated chamber, where this air is used to remove moisture from the
adsorbent, after which it is vented to the atmosphere. The active chamber switches on a cyclical
basis. The dry air then passes through the non-return valve (3) into the air tank (2). Air drying
efficiency (the pressure dew point) is determined by the dew point sensor (15) located in the air
tank.
8.2. Compressor cabinet
(Fig. 4) The soundproof cabinet provides compact covering of the compressor, dampens noise
efficiently, providing sufficient exchange of cooling air. The fan (9) under the compressor pump
provides cooling of the compressor. It is in operation at the same time with the compressor motor
or after switching on the temperature switch at temperature above 40°C. After cooling the cabinet
area approximately under 32°C, the fan turns off automatically. The dryer display (25) is located
on the front panel of the cabinet.
Risk of compressor overheating.
Make sure that there are no obstacles at the cooling air inlet into the cabinet
(around the bottom part of the cabinet) and at the hot air outlet on the top back
side of the cabinet.
If the compressor is placed on a soft floor, e.g. carpet, create space between
the base and the floor or the cabinet and the floor, e.g. underlay the footings
with hard pads to ensure sufficient cooling of the compressor.
PRODUCT DESCRIPTION
11/2023 13 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
Descriptions for figures 1 - 3
1 Air pump
2 Air tank
3 Non-return valve
4 Pressure switch
5 Safety valve
6 Pressure gauge
7 Drain valve
8 Inlet filter
9 Compressor fan
10 Casters
11 Hour counter
12 Electrical box
13 AD dryer
14 Air outlet
15 Pressure dew point sensor
16 Condensate collection vessel
17 Supporting bracket
18 Cabinet fan
19 Cabinet pressure gauge
20 Switch
21 Cabinet connector
22 Pressure gauge hose
23 Wall stop
24 Pulling system
25 Cabinet display
26 Handle
27 Cabinet gas springs
28 *Dryer display
29 Outlet module
30 Cooling module
31 Electrical panel
32 Dryer chamber
33 Inlet valve module
34 Compressed air inlet
35 Regeneration solenoid valve
36 Dryer fan
37 Condensate separator
38 Condensate drain solenoid valve
39 Air outlet
40 **Bushing
41 Outlet from condensate separator and
regeneration valves
42 Power cord
* Position (28) applies to the DK50 2V/50/M, DK50 2x2V/110/M model without the cabinet;
position (28) in the case of the DK50 2V/50 S/M, DK50 2x2V/110 S/M with the cabinet is a simple
cover.
** For the cabinet model, the cable connected to the display (25) in the front panel of the
cabinet is routed through the universal bushing (40).
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 14 11/2023
Fig. 1: DK50 2V/50/M Compressor with adsorption dryer
PRODUCT DESCRIPTION
11/2023 15 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
Fig. 2: DK50 2x2V/110/M Compressor with adsorption dryer
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 16 11/2023
Fig. 3:Adsorption dryer
ADM 140/50
ADM 280/110
* Position (28) applies to the DK50 2V/50/M, DK50 2x2V/110/M model without the cabinet; position
(28) in the case of the DK50 2V/50 S/M, DK50 2x2V/110 S/M with the cabinet is a simple cover.
** For the cabinet model, the cable connected to the display (25) in the front panel of the cabinet is
routed through the universal bushing (40).
PRODUCT DESCRIPTION
11/2023 17 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
Fig. 4: Cabinet
A - DK50 2V/50S/M
PRODUCT DESCRIPTION
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 18 11/2023
B - DK50 2x2V/110S/M
TECHNICAL DATA
11/2023 19 NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023
TECHNICAL DATA
Compressors are designed for operation in dry, ventilated and dust-free indoor rooms under the
following climactic conditions:
Temperature
+5°C to +40°C
Relative humidity
max. 70%
Working pressure 6 8 bar
DK50 2V/50/M
DK50 2V/50S/M
Rated voltage
Frequency a)
V, Hz
230, 50
3x400, 50
230, 50
3x400, 50
Capacity at 6 bar (FAD) -20°C
l/min
120
120
Working pressure b)
bar
6.0 8.0
6.0 8.0
Rated current
A
8.8
3.9
9.0
4.1
Motor power
kW
1.2
1.2
Air tank volume
l
50
50
Air quality - filtration
m
-
-
Maximum operating pressure of safety
valve
bar
9.0
9.0
Noise level at 5 bar (LpA)
dB
70.5
52.0
Operating mode
%
S1-100
S1-100
PDP drying performance at 7 bar d)
°C
-20
-20
Dryer low pressure warning
bar
< 3
< 3
Dryer high pressure warning
bar
˃ 9
˃ 9
Dryer high dew point warning
°C
˃ -20
˃ -20
Time to fill air tank from 0 to 7 bar
s
185
185
Dimensions (net)
w x d x h
mm
580x600x805
750x715x1015
Net weight c)
kg
74
72
125
123
a)Specify the compressor version when ordering
b)Consult any other range of pressure with the supplier
c)Weight is indicative and only applies to the product without accessories
d)Applies to ambient temperatures of <30°C PDP – pressure dew point
TECHNICAL DATA
NP-DK50 2V 50, 2x2V 110-AD-A-8_11-2023 20 11/2023
Dependence of compressor output on working pressure
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216

EKOM DK50 2V/50 Používateľská príručka

Kategória
Vzduchové kompresory
Typ
Používateľská príručka
Tento návod je vhodný aj pre