Waeco AirCon Service VES100 Návod na používanie

Kategória
Osobné váhy
Typ
Návod na používanie
Refrigerant Scale 8885100099
EN 6 Refrigerant scale
Operating Manual
DE 17 Kältemittelwaage
Bedienungsanleitung
FR 28 Balance de réfrigérant
Notice d’utilisation
ES 39 Báscula de refrigerante
Instrucciones de uso
PT 50 Balança de agente refrigerante
Manual de instruções
IT 61 Bilancia per refrigerante
Istruzioni per l’uso
NL 72 Koudemiddelweegschaal
Gebruiksaanwijzing
DA 83 Kølemiddelvægt
Betjeningsvejledning
SV 93 Våg för köldmedium
Bruksanvisning
NO 104 Kjølemiddelvekt
Bruksanvisning
FI 114 Kylmäainevaaka
Käyttöohje
RU 125 Весы для хладагента
Инструкция по эксплуатации
PL 137 Waga czynnika chłodniczego
Instrukcja obsługi
SK 148 Váha chladiaceho prostriedku
Návod na obsluhu
CS 158 Váha chladiva
Návod k obsluze
HU 168 Hűtőközeg-mérleg
Használati utasítás
© 2023 Dometic Group. The visual appearance of the contents of this manual is pro-
tected by copyright and design law. The underlying technical design and the prod-
ucts contained herein may be protected by design, patent or pending patent. The
trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are
reserved.
RefrigerantScale
3
1 2
34
1
12
3
2
RefrigerantScale
4
61
23
5
4
3
1234
5
6
8
7
4
RefrigerantScale
5
5
6
EN
Explanation of symbols RefrigerantScale
6
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in
order to ensure that you install, use, and maintain the product properly at all times. These instructions MUST stay with this prod-
uct.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you
understand and agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended
purpose and application and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as
well as in accordance with all applicable laws and regulations. A failure to read and follow the instructions and warnings set forth
herein may result in an injury to yourself and others, damage to your product or damage to other property in the vicinity. This
product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and
updates. For up-to-date product information, please visit documents.dometic.com.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Replacing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1 Explanation of symbols
!
!
WARNING!
Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in minor or moderate injury.
EN
RefrigerantScale Safety instructions
7
A
I
2 Safety instructions
2.1 General safety
!WARNING! Failure to obey these warnings could result in
death or serious injury.
Do not operate the device if it is visibly damaged.
If this device's power cable is damaged, it must be replaced
by the manufacturer, customer service or a similarly qualified
person in order to prevent safety hazards.
This appliance may only be repaired by qualified personnel.
Inadequate repairs may cause serious hazards.
This device can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
device in a safe way and understand the hazards involved.
Cleaning and user maintenance must not be carried out by
unsupervised children.
Children must not play with the device.
Children must be supervised to ensure that they do not play with
the device.
Always keep and use the device out of the reach of children
under 8 years of age.
!CAUTION! Failure to obey these cautions could result in
minor or moderate injury.
Disconnect the device from the mains
before cleaning and maintenance
after every use
NOTICE!
Indicates a situation that, if not avoided, can result in property
damage.
NOTE
Supplementary information for operating the product.
EN
Safety instructions RefrigerantScale
8
ANOTICE! Damage hazard
Check that the voltage specification on the data plate is the
same as that of the power supply.
Connect the device to the AC mains using the AC cable.
Never pull the plug out of the socket by the connection cable.
2.2 Operating the device safely
!CAUTION! Failure to obey these cautions could result in
minor or moderate injury.
Before starting the device, ensure that the power supply line
and the plug are dry.
ANOTICE! Damage hazard
Do not place it near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
Never immerse the device in water.
Protect the device and the cable against heat and moisture.
Do not operate the device over the maximum working pressure
of 30 bar on the magnetic valve.
EN
RefrigerantScale Scope of delivery
9
3 Scope of delivery
4 Intended use
Using the Refrigerant Scale 8885100099, refrigerant can be charged or
recovered into a refrigerant container with a maximum inlet pressure of
30 bar.
This product is only suitable for the intended purpose and application in
accordance with these instructions.
This manual provides information that is necessary for proper installation
and/or operation of the product. Poor installation and/or improper operating
or maintenance will result in unsatisfactory performance and a possible fail-
ure.
The manufacturer accepts no liability for any injury or damage to the product
resulting from:
Incorrect installation, assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare
parts provided by the manufacturer
Alterations to the product without express permission from the manufac-
turer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
No. in
fig. 1, page 3 Description
1 Protective case
2 AC cable
3 Hand display
4Scale
EN
Technical description RefrigerantScale
10
5 Technical description
The scale can be moved and allows weighing outside the protective case.
The hand display is also removable. It can be suspended outside the protec-
tive case.
If no button is pressed, the device automatically switches off after 30 minutes.
The quantity of refrigerant is determined using the scale.
A solenoid valve in the device opens or closes the connection between both
the “Input” and “Output” connections.
5.1 Hand display element
No. in
fig. 2, page 3 Description
1 “Input” connection (max. 30 bar)
2 “Output” connection
3 On/off switch
No. in
fig. 3, page 4 Description
1 Battery indicator
2 Weighing unit
3 Numeric display
4 “Recovery” display
5 “Charging” display
6 Over load display
EN
RefrigerantScale Technical description
11
5.2 Hand display control element
Buttons are simultaneously assigned numbers and the following functions:
No. in
fig. 4, page 4 Description Explanation
1 “Charge” button Starts the charging.
2 “Function” button Selects the weight unit.
3 “Light” button Switches the backlight on and
off.
4 “Clear” button Deletes all entries and returns
to scale mode.
5 “Repeat” button Uses the previously selected
weight and repeats the
charging/recovery procedure.
6 “Enter” button Displays the current weight.
7 “Power” button Switches the device on and off.
8 “Recover” button Switches the display on in the
hand display.
EN
Operation RefrigerantScale
12
6 Operation
A
I
6.1 Selecting the weight unit
The refrigerant unit has three weight units: kilograms (kg), ounces (oz) and
pounds (lb).
Press the “Function” button (fig. 42, page 4) several times in order to
select the weight unit required.
6.2 Switching on the backlight
The backlight switches off automatically after 30 minutes without a button
being pressed.
Press the “Light” button (fig. 43, page 4) to switch the backlight of the
display on or off.
NOTICE!
Ensure that the maximum capacity of the scale is not
exceeded as this may damage the device.
The maximum inlet pressure shall not exceed 30 bar.
NOTE
The scale can be set up in the case as well as outside the
case. The scale must be on a flat surface and must not
touch the connection cable as this may otherwise affect the
precision.
Place the refrigerant bottle at the center of the scale and
ensure that you do not shake the refrigerant beforehand.
Cover the “Input” and “Output” connections with the safety
caps prior to each use.
Switch off the device after every use. Remove the batteries if
the device is to be stored or will not be used for an extended
period.
EN
RefrigerantScale Operation
13
6.3 Charging refrigerant
I
1. Connect the device to the AC mains using the AC cable
(fig. 11, page 3).
2. Connect a filled refrigerant bottle to the “Input” connection
(fig. 21, page 3).
3. Connect the gas bottle to be filled to the “Output” connection
(fig. 22, page 3).
4. Switch on the device using the on/off switch (fig. 23, page 3).
5. Place the filled gas bottle on the scale (fig. 5, page 5).
6. Wait until the scale has determined the current weight and shown this in
the display.
7. Press the “Charge” button (fig. 31, page 4).
8. Enter the intended charging weight (min. 50 g) using the numerical keys.
9. Press the “Enter” button (fig. 36, page 4).
The solenoid valve is opened and the refrigerant is charged.
The solenoid valve closes when the selected refrigerant quantity has
been charged.
The device displays the quantity of refrigerant remaining in the filled
refrigerant gas bottle.
I
6.4 Recovering refrigerant
I
NOTE
The refrigerant scale must be connected to the AC mains in order
for the solenoid valve to work.
NOTE
Press the “Enter” button (fig. 36, page 4) to stop a process
at any time. After this press the “Charge” button
(fig. 31, page 4) to return to the previous screen.
If you want to end the charging process before the selected
quantity of refrigerant has been reached, press the “0” button.
Press the “Enter” button (fig. 36, page 4) to exit the mode.
NOTE
If the weight selected exceeds the total weight of refrigerant in
the gas bottle, the fault message “ERROR” is displayed.
The weight of the bottle to be filled must not exceed 80 % of
the total quantity.
EN
Replacing the batteries RefrigerantScale
14
1. Connect the gas bottle to a recovery system (fig. 6, page 5).
2. Connect the device to the AC mains using the AC cable
(fig. 11, page 3).
3. Connect the “Output” connection to the air conditioning service station
(fig. 22, page 3).
4. Connect the gas bottle from which refrigerant is to be recovered to the
“Input” connection (fig. 21, page 3).
5. Switch on the device using the on/off switch (fig. 23, page 3).
6. Place the filled gas bottle to be emptied on the scale.
7. Wait until the scale has determined the current weight and displayed this.
8. Press the “Recover” button (fig. 38, page 4).
9. Enter the weight to be removed (min. 50 g) using the numerical keys.
10.Press the “Enter” button (fig. 36, page 4).
The solenoid valve is opened and the refrigerant extracted.
The solenoid value closes when the selected quantity of refrigerant has
been charged.
The device displays the remaining quantity of refrigerant in the filled
refrigerant bottle.
I
6.5 Repeating the process
After charging or recovering, press the “Repeat” button (fig. 35,
page 4) in order to charge the previously selected weight again.
7 Replacing the batteries
1. Open the cover on the back of the hand display.
2. Replace the batteries (9 V).
3. Close the cover.
NOTE
Press the “Enter” button fig. 36, page 4) to stop a process at
any time. After this press the “Recover” button
(fig. 38, page 4) to return to the previous screen.
If you want to end the charging process before the selected
quantity of refrigerant has been reached, press the “0” button.
Press the “Enter” button (fig. 36, page 4) to exit the mode.
EN
RefrigerantScale Troubleshooting
15
8 Troubleshooting
9 Cleaning and maintenance
A
Occasionally clean the product with a damp cloth.
10 Warranty
The statutory warranty period applies. If the product is defective, please
contact your retailer or the manufacturer's branch in your country
(see dometic.com/dealer).
For repair and warranty processing, please include the following documents
when you send in the product:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
Note that self-repair or non-professional repair can have safety conse-
quences and might void the warranty.
Problem Remedy
“ERROR” is shown on
the display.
Press the “Power” button and wait for 3 seconds. Press
the “Power” button again to restart the system.
The display does not
react.
NOTICE! Damage hazard
Do not use sharp or hard objects or cleaning agents for cleaning
as these may damage the product.
EN
Disposal RefrigerantScale
16
11 Disposal
Recycling packaging material
Recycling products with batteries, rechargeable batteries, and light
sources
12 Technical data
Place the packaging material in the appropriate recycling waste bins
wherever possible.
Remove any batteries, rechargeable batteries, and light sources
before recycling the product.
Return defective or used batteries to your retailer or dispose of them
at collection points.
Do not dispose of any batteries, rechargeable batteries, and light
sources with general household waste.
If you wish to finally dispose of the product, ask your local recycling
center or specialist dealer for details about how to do this in accor-
dance with the applicable disposal regulations.
The product can be disposed free of charge.
Refrigerant Scale 8885100099
Ref. no. 8885100099
Inlet pressure max. 30 bar
Weighing capacity 100 kg/220 lbs/3528 oz
Resolution 5 g/0.01 lbs/0.2 oz
Accuracy 0.05 %
Voltage 110 – 240 Vw
Ambient temperature –10 to +40 °C
≤75% humidity
Refrigerant connections 1/4"
Scale dimensions 237 mm x 237 mm
Weight 5 kg
DE
RefrigerantScale Erläuterung der Symbole
17
Lesen und befolgen Sie bitte alle Anweisungen, Richtlinien und Warnhinweise in diesem Produkthandbuch sorgfältig, um sicher-
zustellen, dass Sie das Produkt ordnungsgemäß installieren und stets ordnungsgemäß betreiben und warten. Diese Anleitung
MUSS bei dem Produkt verbleiben.
Durch die Verwendung des Produktes bestätigen Sie hiermit, dass Sie alle Anweisungen, Richtlinien und Warnhinweise sorg-
fältig gelesen haben und dass Sie die hierin dargelegten Bestimmungen verstanden haben und ihnen zustimmen. Sie erklären
sich damit einverstanden, dieses Produkt nur für den angegebenen Verwendungszweck und gemäß den Anweisungen, Richt-
linien und Warnhinweisen dieses Produkthandbuchs sowie gemäß allen geltenden Gesetzen und Vorschriften zu verwenden.
Eine Nichtbeachtung der hierin enthaltenen Anweisungen und Warnhinweise kann zu einer Verletzung Ihrer selbst und anderer
Personen, zu Schäden an Ihrem Produkt oder zu Schäden an anderem Eigentum in der Umgebung führen. Dieses Produkt-
handbuch, einschließlich der Anweisungen, Richtlinien und Warnhinweise, sowie die zugehörige Dokumentation können Ände-
rungen und Aktualisierungen unterliegen. Aktuelle Produktinformationen finden Sie unter documents.dometic.com.
Inhalt
1 Erläuterung der Symbole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2 Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3 Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4 Bestimmungsgemäßer Gebrauch . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Technische Beschreibung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6 Bedienung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7 Batterien wechseln. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8 Fehlersuche und Fehlerbehebung . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9 Reinigung und Pflege. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
11 Entsorgung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
12 Technische Daten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1 Erläuterung der Symbole
!
!
WARNUNG!
Sicherheitshinweis: Kennzeichnet eine Gefahrensituation, die
zum Tod oder schwerer Verletzung führen könnte, wenn die
jeweiligen Anweisungen nicht befolgt werden.
VORSICHT!
Sicherheitshinweis: Kennzeichnet eine Gefahrensituation, die
zu geringer oder mittelschwerer Verletzung führen könnte, wenn
die jeweiligen Anweisungen nicht befolgt werden.
DE
Sicherheitshinweise RefrigerantScale
18
A
I
2 Sicherheitshinweise
2.1 Grundlegende Sicherheit
!WARNUNG! Nichtbeachtung dieser Warnungen kann zum Tod
oder schwerer Verletzung führen.
Wenn das Gerät sichtbare Beschädigungen aufweist, dürfen
Sie es nicht in Betrieb nehmen.
Wenn das Anschlusskabel dieses Geräts beschädigt ist, muss
es durch den Hersteller oder seinen Kundendienst bzw. eine
entsprechend ausgebildete Fachkraft ersetzt werden, um
Gefahren zu verhindern.
Reparaturen an diesem Gerät dürfen nur von qualifiziertem Per-
sonal durchgeführt werden. Durch unsachgemäße Reparaturen
können erhebliche Gefahren entstehen.
Dieses Gerät kann von Kindern ab 8 Jahren und von Personen
mit verringerten physischen, sensorischen oder mentalen
Fähigkeiten oder Mangel an Erfahrung und/oder Wissen ver-
wendet werden, wenn diese Personen beaufsichtigt werden
oder im sicheren Gebrauch des Geräts unterwiesen wurden
und die daraus resultierenden Gefahren verstanden haben.
Reinigung und Benutzerwartung dürfen nicht von Kindern ohne
Beaufsichtigung durchgeführt werden.
Kinder dürfen nicht mit dem Gerät spielen.
Kinder sollten beaufsichtigt werden, um sicherzustellen, dass
sie nicht mit dem Gerät spielen.
Verwahren und benutzen Sie das Gerät außerhalb der Reich-
weite von Kindern unter 8 Jahren.
ACHTUNG!
Kennzeichnet eine Situation, die zu Sachschäden führen kann,
wenn die jeweiligen Anweisungen nicht befolgt werden.
HINWEIS
Ergänzende Informationen zur Bedienung des Produktes.
DE
RefrigerantScale Sicherheitshinweise
19
!VORSICHT! Nichtbeachtung dieser Hinweise kann zu leichten
bis mittelschweren Verletzungen führen.
Trennen Sie das Gerät vom Netz
vor der Reinigung und Wartung
nach jedem Gebrauch
AACHTUNG! Beschädigungsgefahr
Prüfen Sie, ob die Spannungsangabe auf dem Typenschild mit
der vorhandenen Netzspannung übereinstimmt.
Schließen Sie das Gerät mit dem Wechselstromkabel an das
Wechselstromnetz an.
Ziehen Sie den Stecker nie am Anschlusskabel aus der Steck-
dose.
2.2 Sicherheit beim Betrieb des Geräts
!VORSICHT! Nichtbeachtung dieser Hinweise kann zu leichten
bis mittelschweren Verletzungen führen.
Achten Sie vor der Inbetriebnahme darauf, dass Zuleitung und
Stecker trocken sind.
AACHTUNG! Beschädigungsgefahr
Stellen Sie das Gerät nicht in der Nähe von offenen Flammen
oder anderen Wärmequellen (Heizung, starke Sonneneinstrah-
lung, Gasöfen usw.) ab.
Tauchen Sie das Gerät nie in Wasser.
Schützen Sie das Gerät und die Kabel vor Hitze und Nässe.
Nehmen Sie das Gerät nicht über dem maximalen Betriebs-
druck am Magnetventil von 30 bar in Betrieb.
DE
Lieferumfang RefrigerantScale
20
3Lieferumfang
4 Bestimmungsgemäßer Gebrauch
Mit der Kältemittelwaage 8885100099 kann Kältemittel in einen Kältemittel-
behälter mit einem maximalen Einlassdruck von 30 bar eingefüllt oder aufge-
fangen werden.
Dieses Produkt ist nur für den angegebenen Verwendungszweck und die
Anwendung gemäß dieser Anleitung geeignet.
Dieses Handbuch enthält Informationen, die für die ordnungsgemäße Instal-
lation und/oder den ordnungsgemäßen Betrieb des Produkts erforderlich
sind. Installationsfehler und/oder ein nicht ordnungsgemäßer Betrieb oder
eine nicht ordnungsgemäße Wartung haben eine unzureichende Leistung
und u. U. einen Ausfall des Geräts zur Folge.
Der Hersteller übernimmt keine Haftung für Verletzungen oder Schäden am
Produkt, die durch Folgendes entstehen:
unsachgemäße Montage oder falscher Anschluss, einschließlich Über-
spannung
unsachgemäße Wartung oder Verwendung von anderen als den vom
Hersteller gelieferten Original-Ersatzteilen
Veränderungen am Produkt ohne ausdrückliche Genehmigung des Her-
stellers
Verwendung für andere als die in der Anleitung beschriebenen Zwecke
Dometic behält sich das Recht vor, das Erscheinungsbild des Produkts und
dessen technische Daten zu ändern.
Nr. in
Abb. 1, Seite 3 Beschreibung
1 Schutzkoffer
2 Wechselstromkabel
3 Hand-Display
4 Transportsicherung
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180

Waeco AirCon Service VES100 Návod na používanie

Kategória
Osobné váhy
Typ
Návod na používanie