Dometic ColdMachine 50, 54, 55, 84, 85, 86, 94, 95, 96, CS-NC15, 50 Cold Machine Návod na inštaláciu

  • Prečítal som si návod na obsluhu chladiacich jednotiek Dometic. Som pripravený odpovedať na vaše otázky týkajúce sa inštalácie, prevádzky, riešenia problémov a ďalších funkcií týchto zariadení. Návod obsahuje podrobné informácie o rôznych modeloch, vrátane ich technických parametrov a možnosti prevádzky z rôznych zdrojov energie.
  • Ako môžem prevádzkovať chladiacu jednotku z 230V siete?
    Čo mám robiť, ak sa chladiaca jednotka vypne kvôli nízkeho napätia?
    Ako môžem vyčistiť kondenzátor?
ColdMachine 50, 54, 55, 84, 85, 86, 94, 95, 96, CS-NC15
VD-01, VD-02, VD-03, VD-04, VD-05, VD-06, VD-07, VD-08,
VD-09, VD-14N, VD-15, VD-16, VD-18, VD-21
Cooling unit
Installation and Operating Manual. . . . . . . 13
Kühlaggregat
Montage- und Bedienungsanleitung . . . . .36
Groupe frigorifique
Instructions de montage
et de service . . . . . . . . . . . . . . . . . . . . . . . . .60
Unidad frigorífica
Instrucciones de montaje y de uso . . . . . . .85
Unidade de refrigeração
Instruções de montagem e manual de
instruções . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Gruppo refrigerante
Istruzioni di montaggio e d’uso . . . . . . . .134
Koelaggregaat
Montagehandleiding en
gebruiksaanwijzing . . . . . . . . . . . . . . . . . .159
Køleaggregat
Monterings- og betjeningsvejledning . . .183
Kylaggregat
Monterings- och bruksanvisning . . . . . . . 206
Kjøleaggregat
Monterings- og bruksanvisning. . . . . . . . 229
Jäähdytysaggregaatti
Asennus- ja käyttöohje . . . . . . . . . . . . . . . 251
Холодильный агрегат
Инструкция по монтажу и эксплуатации 274
Agregat chłodzący
Instrukcja montażu i obsługi. . . . . . . . . . . 300
Chladiaci agregát
Návod na montáž a uvedenie
do prevádzky. . . . . . . . . . . . . . . . . . . . . . . 325
Chladicí agregát
Návod k montáži a obsluze . . . . . . . . . . . 348
Hűtőszülék
Szerelési és használati útmutató . . . . . . . 372
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
REFRIGERATION
COOLING UNIT
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 1 Tuesday, May 4, 2021 7:24 PM
© 2021 Dometic Group. The visual appearance of the contents of this manual is
protected by copyright and design law. The underlying technical design and the
products contained herein may be protected by design, patent or be patent
pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
All rights are reserved.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 2 Tuesday, May 4, 2021 7:24 PM
Coldmachine
3
A
1
2
B
2
3
4
5
6
7
0
1
1
2
1
1
2
3
4
5
6
min max
Hauptschalter
Main Switch
Commutateur
principal
Kompressor ein
Compressor on
Compresseur en fonction
Fremdversorgung
External Voltage
Alimentation Extérieure
Speicherabruf
Discharge of Cold Accum.
Décharge de la Plaque
Temperature
Electronic
Control
2
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 3 Tuesday, May 4, 2021 7:24 PM
Coldmachine
4
VD-01, VD-04, VD-08
10 mm
10 mm
10 mm
10 mm
10 mm
3
VD-03
min. 30 mm
4
VD-02, VD-05, VD-18, VD-21
10 mm
10 mm
10 mm
5
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 4 Tuesday, May 4, 2021 7:24 PM
Coldmachine
5
VD-06
6
VD-07, VD-09
10 mm
1/3
2/3
7
VD-14N, VD-15
1/32/3
1
2
3
4
5
8
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 5 Tuesday, May 4, 2021 7:24 PM
Coldmachine
6
VD-16
F
T
D
C
P
1
gn/ge
br
sw
gr
bl
9
VD-14N, VD-15
1
F
T
D
C
P
gn/ge
gr
bl
br
sw
0
b
a
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 6 Tuesday, May 4, 2021 7:24 PM
Coldmachine
7
2
1
3
c
AB
CD
d
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 7 Tuesday, May 4, 2021 7:24 PM
Coldmachine
8
1. 2.
e
2 mm
3 mm
g
f
Ø
/mm²
l/m
12 V
24 V
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
0
2
6
10
14
h
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 8 Tuesday, May 4, 2021 7:24 PM
Coldmachine
9
VD-01, VD-02, VD-03, VD-04, VD-05,
VD-07, VD-08, VD-09, VD-18 , VD-21
rt
swblgn/ge
sw / b l
2
3
4
5
6
7
0
1
br
12 3
4
i
12 3
4
brgn w s
rt
T
P
C
sw / b l
VD-06
j
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 9 Tuesday, May 4, 2021 7:24 PM
Coldmachine
10
bl br ge gn gr rt sw ws
EN Blue Brown Yellow Green Grey Red Black White or
DE Blau Braun Gelb Grün Grau Rot Schwarz Weiss oder
FR Bleu Marron Jaune Vert Gris Rouge Noir Blanc ou
ES Azul Marrón Amarillo Verde Gris Rojo Negro Blanco o bien
PT Azul Castanho Amarelo Verde Cinzento Vermelho Preto Branco ou
IT Blu Marrone Giallo Verde Grigio Rosso Nero Bianco oppure
NL Blauw Bruin Geel Groen Grijs Rood Zwart Wit of
DA Blå Brun Gul Grøn Grå Rød Sort Hvid eller
SV Blå Brun Gul Grön Grå Röd Svart Vit eller
NO Blå Brun Gul Grønn Grå Rød Svart Hvit eller
FI Sininen Ruskea Keltainen Vihreä Harmaa Punainen Musta Val-
koinen
tai
RU Синий Коричне-
вый
Желтый Зеленый Серый Красный Черный Белый или
PL Niebieski Brązowy Żółty Zielony Szary Czerwony Czarny Biały lub
SK Modrá Hnedá Žltá Zelená Sivá Červená Čierna Biela alebo
CS Modrá Hněda Žlutá Zelená Šedá Červená Černá Bílá nebo
HU Kék Barna Sárga Zöld Szürke Piros Fekete Fehér vagy
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 10 Tuesday, May 4, 2021 7:24 PM
Coldmachine
11
257 mm
81 mm
9,50 mm
9,50 mm
128,50 mm
360 mm
281 mm
k
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 11 Tuesday, May 4, 2021 7:24 PM
Coldmachine
12
~ 215 mm
~ 310 mm
l
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 12 Tuesday, May 4, 2021 7:24 PM
EN
Coldmachine Explanation of symbols
13
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure
that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and
agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application
and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli-
cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and
others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and
warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit
dometic.com.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
7 Installing the cooling unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
8 Using the cooling unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9 Use coolant accumulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
11 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
13 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
1 Explanation of symbols
D
!
DANGER!
Safety instruction: Indicates a hazardous situation that, if not avoided,
will result in death or serious injury.
WARNING!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in death or serious injury.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 13 Tuesday, May 4, 2021 7:24 PM
EN
Safety instructions Coldmachine
14
!
A
I
2 Safety instructions
2.1 General safety
D
DANGER!
Danger of fatalinjuries!
When using the device on boats: if the device is powered by the
mains, ensure that the power supply has a residual current circuit
breaker!
!
WARNING!
This device may only be installed and repaired by a qualified
technician. Inadequate repairs can lead to considerable hazards.
Should your device need to be repaired, please contact customer
services.
Do not operate the device if it is visibly damaged.
Do not open the refrigerant circuit under any circumstances. An
exception to this is when the device has to be disconnected for return
shipping (chapter “Installing the external temperature regulator” on
page 21).
Set up the device in a dry location where it is protected against splash-
ing water.
Do not place the device near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
Make sure that the compressor is sufficiently ventilated.
Electronic devices are not toys!
Always keep and use the device out of the reach of children.
CAUTION!
Safety instruction: Indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided, can result in property damage.
NOTE
Supplementary information for operating the product.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 14 Tuesday, May 4, 2021 7:24 PM
EN
Coldmachine Safety instructions
15
People (including children) whose physical, sensory or mental
capacities or whose lack of experience or knowledge prevent them
from using this product safely should not use it without the supervision
or instruction of a responsible person.
Before you start up the device for the first time, check that the
operatingvoltage matches the battery voltage (see type plate).
If the connection cable is damaged, it must be replaced to prevent
possible electrical hazards. Only replace a damaged connection
cable with a connection cable of the same type and specifications.
Do not store any explosive substances, such as spray cans with
propellants in the device.
2.2 Operating the device safely
D
DANGER! Danger of fatal injuries!
Do not touch exposed cables with your bare hands. This especially
applies when operating the device from the AC mains.
A
NOTICE!
Never use cleaners that contain sand, acids or solvents to clean the
evaporator.
Protect the device against rain and moisture.
Disconnect the cooling device and other consumer units from the
battery before you connect the quick charging device.
I
NOTE
Disconnect the device if you are not going to use it for a prolonged
period.
2.3 Safety precautions when handling batteries
!
CAUTION! Danger of injury!
Batteries contain aggressive and caustic acids. Avoid battery fluid
coming into contact with your body. If your skin does come into
contact with battery fluid, wash the part of your body in question
thoroughly with water.
If you connect the device to a battery, make sure that no food comes
into contact with the battery acid.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 15 Tuesday, May 4, 2021 7:24 PM
EN
Scope of delivery Coldmachine
16
3Scope of delivery
4Accessories
If you wish to operate the cooling unit from the 230 V AC mains, please use one of
the following rectifiers.
Available as accessory (not included in scope of delivery):
5 Intended use
The cooling unit is suited for building your own refrigerator or cooler.
The cooler unit is suitable for cooling and freezing food. The device is also suitable
for use on boats.
This product is only suitable for the intended purpose and application in accordance
with these instructions.
This manual provides information that is necessary for proper installation and/or
operation of the product. Poor installation and/or improper operating or mainte-
nance will result in unsatisfactory performance and a possible failure.
The manufacturer accepts no liability for any injury or damage to the product
resulting from:
Incorrect assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare parts
provided by the manufacturer
Quantity Description
1 Cooling unit or evaporator
1 Operating manual
Description Item number
CoolPower EPS100 rectifier
For devices with BD35F compressor (50/80/CS/CS series)
9600000440
CoolPower MPS35 rectifier
For devices with BD35F compressor (50/80/CS/CS series)
9600000445
CoolPower MPS50 rectifier
For devices with BD50F compressor (90 series)
9600000441
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 16 Tuesday, May 4, 2021 7:24 PM
EN
Coldmachine Technical description
17
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
6 Technical description
The cooling units are suitable for use with 12 V or 24 V DC voltage and can therefore
be used for camping or on boats. Furthermore, you can connect them to a 230 V
mains supply via the rectifiers (see chapter “Accessories” on page 16).
When used on boats, the cooling unit can withstand a constant heeling of 30°.
The cooling unit must be used together with an evaporator. In addition, you can use
an accumulator with or without TEC control. The CS-NC15 comprises a cooling unit
and an evaporator.
Use the continuously variable thermostat on the evaporator to set the desired
temperature.
The accumulator and TEC program control ensure a high cooling capacity
and improve the unit’s efficiency. The accumulator is charged when there is
a sufficient supply of power (for example when powered by a mains adapter). In the
event of accumulator usage or under-voltage, the coolant is drawn from the
accumulator until it is empty. Thus, no power is taken from the battery during this
time.
The TEC program control always ensures that
Cold energy is stored if there is excess electrical energy (external supply of power
by a generator).
The coolant accumulator can be used at any time to ensure that the complete
battery power is used for other consumers.
Stored cold energy is automatically retrieved to preserve the interior cooling
temperature of the cooling area, once the battery capacity is exhausted.
I
NOTE
Further information on the coolant accumulator can be found in chapter
“Use coolant accumulator” on page 27.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 17 Tuesday, May 4, 2021 7:24 PM
EN
Installing the cooling unit Coldmachine
18
6.1 Battery monitor
The cooling device is equipped with an electronic device to protect against revers-
ing the polarity when connecting to a battery. To protect the battery, the cooling
device switches off automatically if the voltage is insufficient (see following table).
Devices without TEC control
Devices with TEC control
7 Installing the cooling unit
!
7.1 Tools required
For installation and assembly, you will need the following tools:
•Drill
Screwdriver
Open-ended spanner: 16 mm, 19 mm and 21 mm
Sealant and PUR foam
Cable, cable lugs and cable clips
•Ester oil
Connection voltage Switch-off voltage Restart voltage
12 V
10.4 V 11.7 V
24 V
22.8 V 24.2 V
Connection voltage Switch-off voltage Restart voltage
12 V
10.7 V 13.0 V
24 V
22.0 V 26.0 V
WARNING!
The installation may only be performed by a qualified technician.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 18 Tuesday, May 4, 2021 7:24 PM
EN
Coldmachine Installing the cooling unit
19
7.2 Notes on the cooling container
Permitted cooling area contents
Make sure that maximum cooling area contents specified are not exceeded for the
respective evaporator type (see chapter “Technical data” on page 31).
Minimum insulation
The maximum cooling area contents are based on a minimum insulation thickness of
35 mm of foam polyurethane with a density of 40 kg/m³. If other insulating materials
are used such as styrofoam, double the wall thickness to attain the same level of heat
insulation.
Installing the evaporator
The evaporator must be installed in the cooling container (except CS-NC15, the
evaporator is premounted).
Observe the following in the process:
Correct installation position (fig. 3, page 4 up to fig. 9, page 6)
Arrangement in the cooling container as far to the top as possible
Install a least 10 mm from the wall (not VD-14N and VD-15).
A
Connecting the evaporator
Connect the evaporators VD-14N and VD-15 in accordance with fig. 0,
page 6.
Connect evaporator VD-16 according to fig. 9, page 6.
Connect other evaporators according to fig. i, page 9.
NOTICE!
For cooling units without valve couplings (ready-to install units): Do not
open the refrigerant circuit during installation. You may have to make the
wall openings larger to be able to slide the evaporator through them
(fig. a, page 6). Or alternatively, you create an opening that allows you
to install the cooling lines at the top (fig. b, page 6).
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 19 Tuesday, May 4, 2021 7:24 PM
EN
Installing the cooling unit Coldmachine
20
Keys for the illustrations
A
For cooling units with valve couplings
Cut out a hole with a diameter of at least 30 mm (fig. c, page 7) for the cooling
lines. To do this, use a circular cutter.
No. in fig. 8,
page 5
Explanation
1 DC fan
2 Thermostat button
3 Connection plug for DC fan
4 Thermostat
5 Connection cable
No. in fig. 9,
page 6
Explanation
1 Connection cable
No. in fig. 0,
page 6
Explanation
1 Connection cable
No. in
fig. i, page 9 and
fig. j, page 9
Explanation
1 Connection block
2 Compressor
3Fan
4 Switch fig. i or TEC controller fig. j
NOTICE!
Carefully insulate and seal off the wall openings after installation to
prevent moisture penetration.
DometicColdMachine50-54-55-84-85-86-94-95-96-CS-NC15_IOM_4445100001_EMEA16_20xx-xx-xx.book Page 20 Tuesday, May 4, 2021 7:24 PM
/