4 Programming
Selecting the channel is absolutely necessary to ensure proper operation.
1. Insert the battery in the transmitter(TX).
The LEDDL2 flashes slowly 1 ×.
2. Press theP1 button until the LEDDL2 flashes.
The display corresponds to the set channel.
Depending on the channel, the display is repeated 4 – 8 ×. During this time the channel
canbechanged.
3. Press theP1 button repeatedly until the desired channel is set.
The LEDDL2 flashes according to the new set channel.
Depending on the channel, the display is repeated 4 – 8 ×.
If the LEDDL2 flashes 1 × slowly, the new channel is saved.
4. Repeat the process on the receiver(RX). Set the same channel as on the transmitter(TX).
NOTE
If multiple photocell pairs are being used, program a different channel for each photocell pair.
5 Technical data
Connecting voltage 12 – 24 V~ / 12 – 24 V– /
3V battery, type:CR2 BG1, lithium
Power consumption Tx = 40μA battery, Rx = 30mA
Protection category IP 54
Operating temperature –20°C – +55°C
Alignment Automatic
Nominal range 20m (with connection cable)
10m (with battery)
Horizontal mechanical adjustment angle –90° / +90°
Vertical optical self-adjustment angle ±7° (20 m) ±13.5° (5 m)
Technology Relay – N.C.
6 EU Declaration of Conformity
Manufacturer HörmannKGVerkaufsgesellschaft
Address Upheider Weg 94-98
33803 Steinhagen
Germany
The manufacturer above herewith declares under his sole responsibility that the product
Equipment / system One-way photocell
Model EL71-B
Intended use Supplementary safety device for power operated doors
is in compliance with the essential requirements and other relevant provisions of the below
mentioned EU Directives when used for their intended use:
2014/30/EU(EMC) EU Electromagnetic Compatibility Directive
2015/863/EU(RoHS) Restriction of Use of Hazardous Substances
16 4549207 B3 / 14-2022