Samsung AE200RNWMEG/EU Používateľská príručka

Typ
Používateľská príručka

Táto príručka je tiež vhodná pre

Air conditioner
Installation manual
Thank you for purchasing this Samsung air conditioner.
Before operating this unit, please read this manual carefully and retain it for future
reference.
2
Disassembly and Reassembly
Repairs must be carreid out by trained professional.
For any repairs, please contact our service provider or independent qualified professional.
AE200RNW*EG / AE260RNW*EG / AE260RNW*GG
No Parts Procedure Remark
1 Electrical
equipment parts
1) Remove ** screws from the Cabinet.
(Use + Screw Driver)
2) Remove the 4 screws and then
separate the Cover Control Box part.
(Use + Screw Driver)
3) Remove the Power, Pump, 3way valve,
Flow sensor, Booster Heater, Back-up
Heater, Sensor connector of Assy PCB.
3
No Parts Procedure Remark
4) Remove the 3 screws from the front
part..
5) Remove the 2 screw and then open the
cover in the middle position of water tank
6)Remove the wire of the thermostat and
booster heater
4
Disassembly and Reassembly
No Parts Procedure Remark
2 Expansion Vessel 7) Remove the 2 screw from the front
parts
8) Separate the pipe connected expansion
vessel by 2 nut joints.
3 Pump 9) Disconnect power and communication
connection
10) Separate the pipe connected Pump by
2 nut joints.
4 Flow sensor 11) Separate the pipe connected flow sen
-
sor by 2 bracket holder.
5
No Parts Procedure Remark
5 Back up Heater 12) Remove the 4 screw front the cabi top
parts
13) Separate the pipe connected Back up
heater by 2 nut joints.
6 3way Valve 14) Separate the pipe connected 3way
valve by 3 bracket holder
7 Anode bar 15) Separate the pipe connected anode
bar by 1 nut joint from top of the tank
6
Disassembly and Reassembly
No Parts Procedure Remark
8 Plate Heat
Exchanger
16) Remove the 2 screw from the bracket valve
17) Remove the 2 screw front the cabi top sub
18) Separate the pipe connected Assy plate
heat exchanger by 2 nut joint
7
COMMISSION REGULATION (EU) No 813/2013
I)
A Model(s) : AE040RXEDEG / AE200RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
5 kW P
Seasonal space heating
energy efficiency
s
127 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 4,4 kW
-
 COPd
(S)
2,10 -
 Pdh 2,7 kW  COPd
(S)
3,10 -
 Pdh 1,7 kW  COPd
(S)
4,46 -
 Pdh 1,9 kW  COPd
(S)
5,72 -
T Tj = bivalent temperature Pdh 4,4 kW T Tj = bivalent temperature COPd
(S)
2,10 -
U
Tj = operation limit
temperature
Pdh 4,2 kW U
Tj = operation limit
temperature
COPd
(S)
1,51 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 0,8 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 2400 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/58 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
120 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 853 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
8
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE060RXEDEG / AE200RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
6 kW P
Seasonal space heating
energy efficiency
s
129 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 5,3 kW
-
 COPd
(S)
2,00 -
 Pdh 3,2 kW  COPd
(S)
3,23 -
 Pdh 2,1 kW  COPd
(S)
4,47 -
 Pdh 1,9 kW  COPd
(S)
5,72 -
T Tj = bivalent temperature Pdh 5,3 kW T Tj = bivalent temperature COPd
(S)
2,00 -
U
Tj = operation limit
temperature
Pdh 5,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,80 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 1,1 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 2580 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/60 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
120 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 853 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
9
A Model(s) : AE090RXEDEG / AE200RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
8 kW P
Seasonal space heating
energy efficiency
s
127 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 7,1 kW
-
 COPd
(S)
1,76 -
 Pdh 4,3 kW  COPd
(S)
3,23 -
 Pdh 2,8 kW  COPd
(S)
4,62 -
 Pdh 2,6 kW  COPd
(S)
5,88 -
T Tj = bivalent temperature Pdh 7,1 kW T Tj = bivalent temperature COPd
(S)
1,76 -
U
Tj = operation limit
temperature
Pdh 4,9 kW U
Tj = operation limit
temperature
COPd
(S)
1,35 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 3,1 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3960 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/64 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
119 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 860 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
10
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE040RXEDEG / AE260RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
5 kW P
Seasonal space heating
energy efficiency
s
127 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 4,4 kW
-
 COPd
(S)
2,10 -
 Pdh 2,7 kW  COPd
(S)
3,10 -
 Pdh 1,7 kW  COPd
(S)
4,46 -
 Pdh 1,9 kW  COPd
(S)
5,72 -
T Tj = bivalent temperature Pdh 4,4 kW T Tj = bivalent temperature COPd
(S)
2,10 -
U
Tj = operation limit
temperature
Pdh 4,2 kW U
Tj = operation limit
temperature
COPd
(S)
1.51 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 0,8 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 2400 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/58 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
123 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1362 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
11
A Model(s) : AE060RXEDEG / AE260RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
6 kW P
Seasonal space heating
energy efficiency
s
129 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 5,3 kW
-
 COPd
(S)
2,00 -
 Pdh 3,2 kW  COPd
(S)
3,23 -
 Pdh 2,1 kW  COPd
(S)
4,47 -
 Pdh 1,9 kW  COPd
(S)
5,72 -
T Tj = bivalent temperature Pdh 5,3 kW T Tj = bivalent temperature COPd
(S)
2,00 -
U
Tj = operation limit
temperature
Pdh 5,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,80 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 1,1 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 2580 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/60 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
123 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1362 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
12
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE090RXEDEG / AE260RNWSEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
8 kW P
Seasonal space heating
energy efficiency
s
127 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 7,1 kW
-
 COPd
(S)
1,76 -
 Pdh 4,3 kW  COPd
(S)
3,23 -
 Pdh 2,8 kW  COPd
(S)
4,62 -
 Pdh 2,6 kW  COPd
(S)
5,88 -
T Tj = bivalent temperature Pdh 7,1 kW T Tj = bivalent temperature COPd
(S)
1,76 -
U
Tj = operation limit
temperature
Pdh 4,9 kW U
Tj = operation limit
temperature
COPd
(S)
1,35 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 3,1 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3960 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/64 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
128 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1309 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
13
A Model(s) : AE090RXEDGG / AE260RNWSGG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
8 kW P
Seasonal space heating
energy efficiency
s
127 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 7,1 kW
-
 COPd
(S)
1,76 -
 Pdh 4,3 kW  COPd
(S)
3,23 -
 Pdh 2,8 kW  COPd
(S)
4,62 -
 Pdh 2,6 kW  COPd
(S)
5,88 -
T Tj = bivalent temperature Pdh 7,1 kW T Tj = bivalent temperature COPd
(S)
1,76 -
U
Tj = operation limit
temperature
Pdh 4,9 kW U
Tj = operation limit
temperature
COPd
(S)
1,35 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 3,1 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3960 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/64 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
128 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1309 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
14
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE050RXYDEG / AE200RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
5 kW P
Seasonal space heating
energy efficiency
s
125 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 4,4 kW
-
 COPd
(S)
2,16 -
 Pdh 2,7 kW  COPd
(S)
3,17 -
 Pdh 1,7 kW  COPd
(S)
4,03 -
 Pdh 1,7 kW  COPd
(S)
4,73 -
T Tj = bivalent temperature Pdh 4,4 kW T Tj = bivalent temperature COPd
(S)
2,16 -
U
Tj = operation limit
temperature
Pdh 4,2 kW U
Tj = operation limit
temperature
COPd
(S)
2,00 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 0,8 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3060 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/61 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
115 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 890 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
15
A Model(s) : AE080RXYDEG / AE200RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
8 kW P
Seasonal space heating
energy efficiency
s
126 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 7,1 kW
-
 COPd
(S)
1,90 -
 Pdh 4,3 kW  COPd
(S)
3,11 -
 Pdh 2,8 kW  COPd
(S)
4,55 -
 Pdh 2,4 kW  COPd
(S)
5,77 -
T Tj = bivalent temperature Pdh 7,1 kW T Tj = bivalent temperature COPd
(S)
1,90 -
U
Tj = operation limit
temperature
Pdh 6,8 kW U
Tj = operation limit
temperature
COPd
(S)
1,66 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 1,2 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3960 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/63 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
115 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 890 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
16
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE120RXYDEG / AE200RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
12 kW P
Seasonal space heating
energy efficiency
s
138 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 10,6 kW
-
 COPd
(S)
2,16 -
 Pdh 6,5 kW  COPd
(S)
3,45 -
 Pdh 4,2 kW  COPd
(S)
4,57 -
 Pdh 4,4 kW  COPd
(S)
6,12 -
T Tj = bivalent temperature Pdh 12,0 kW T Tj = bivalent temperature COPd
(S)
1,96 -
U
Tj = operation limit
temperature
Pdh 12,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,96 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -10  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup - kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 5940 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
44/64 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
110 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 930 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
17
A Model(s) : AE160RXYDEG / AE200RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
16 kW P
Seasonal space heating
energy efficiency
s
138 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 14,2 kW
-
 COPd
(S)
2,06 -
 Pdh 8,6 kW  COPd
(S)
3,31 -
 Pdh 5,5 kW  COPd
(S)
5,23 -
 Pdh 4,5 kW  COPd
(S)
6,57 -
T Tj = bivalent temperature Pdh 14,2 kW T Tj = bivalent temperature COPd
(S)
2,06 -
U
Tj = operation limit
temperature
Pdh 14,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,82 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 2,0 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 7080 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
44/66 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile L AV Water heating energy efficiency
wh
110 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 930 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
18
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE080RXYDEG / AE260RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
8 kW P
Seasonal space heating
energy efficiency
s
126 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 7,1 kW
-
 COPd
(S)
1,90 -
 Pdh 4,3 kW  COPd
(S)
3,11 -
 Pdh 2,8 kW  COPd
(S)
4,55 -
 Pdh 2,4 kW  COPd
(S)
5,77 -
T Tj = bivalent temperature Pdh 7,1 kW T Tj = bivalent temperature COPd
(S)
1,90 -
U
Tj = operation limit
temperature
Pdh 6,8 kW U
Tj = operation limit
temperature
COPd
(S)
1,66 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 1,2 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 3960 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
40/63 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
123 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1362 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
19
A Model(s) : AE120RXYDEG / AE260RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
12 kW P
Seasonal space heating
energy efficiency
s
138 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 10,6 kW
-
 COPd
(S)
2,16 -
 Pdh 6,5 kW  COPd
(S)
3,45 -
 Pdh 4,2 kW  COPd
(S)
4,57 -
 Pdh 4,4 kW  COPd
(S)
6,12 -
T Tj = bivalent temperature Pdh 12,0 kW T Tj = bivalent temperature COPd
(S)
1,96 -
U
Tj = operation limit
temperature
Pdh 12,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,96 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -10  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup - kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 5940 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
44/64 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
117 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1432 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
20
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR HEAT PUMP SPACE HEATERS AND HEAT PUMP COMBINATION HEATERS
II)
A Model(s) : AE160RXYDEG / AE260RNWMEG
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : yes
G Heat pump combination heater : yes
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump, parameters shall be
declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N
Rated heat output
(*)
Prated
(o)
16 kW P
Seasonal space heating
energy efficiency
s
138 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
-
 Pdh 14,2 kW
-
 COPd
(S)
2,06 -
 Pdh 8,6 kW  COPd
(S)
3,31 -
 Pdh 5,5 kW  COPd
(S)
5,23 -
 Pdh 4,5 kW  COPd
(S)
6,57 -
T Tj = bivalent temperature Pdh 14,2 kW T Tj = bivalent temperature COPd
(S)
2,06 -
U
Tj = operation limit
temperature
Pdh 14,0 kW U
Tj = operation limit
temperature
COPd
(S)
1,82 -
V
For air-to-water heat pumps

Pdh - kW V
For air-to-water heat pumps

COPd
(S)
- -
W Bivalent temperature Tbiv -7  X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 
Y
Cycling interval capacity for
heating
Pcych - kW Z Cycling interval efficiency COPcyc
(AA)
- -
AB Degradation co-efficient
(**)
Cdh 0,9 - AC
Heating water operating limit
temperature
WTOL - 
AD Power consumption in modes other than active mode AE Supplementary heater
AF Off mode P
OFF
0,022 kW N Rated heat output
(*)
Psup 2,0 kW
AG Thermostat-off mode P
TO
0,022 kW
AJ Type of energy input Electrical
(AK)
AH Standby mode P
SB
0,022 kW
AI Crankcase heater mode P
CK
0,000 kW
AL Other items AL Other items
AM Capacity control variable
(AN)
AO
For air-to-water heat pumps :
Rated air flow rate, outdoors
- 7080 m
3
/h
(AP)
AQ
Sound power level, indoors/
outdoors
L
WA
44/66 dB
AS
For water-/brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
- - m
3
/h
(AP)
AR Emissions of nitrogen oxides NOx - mg/kWh
AT For heat pump combination heater AT For heat pump combination heater
AU Declared load profile XL AV Water heating energy efficiency
wh
117 %
AW Daily electricity comsumption Q
elec
- kWh AX Daily fuel consumption Q
fuel
- kWh
AY Annual electricity consumption AEC 1432 kWh AY Annual electricity consumption AEC - GJ
AZ Contact details
Samsung Electronics, PO Box 12987, Blackrock, Co. Dublin, Ireland
or Blackbushe Business Park, Yateley, Gu46 6GG, UK
BA
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
BB
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
BC
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BD
2)
If you are a professional looking for information on non-destructive disassembly, dismantling and battery removability, please send an email to: [email protected]om
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Samsung AE200RNWMEG/EU Používateľská príručka

Typ
Používateľská príručka
Táto príručka je tiež vhodná pre