Nilfisk-ALTO NEPTUNE 4 FA Operating Instructions Manual

Typ
Operating Instructions Manual
NEPTUNE 4 FA
Operating Instructions ...............1-18
Betriebsanleitung ......................19-36
Notice d'utilisation ..................... 37-54
Gebruiksaanwijzing ..................55-72
Istruzioni sull’uso
.......................73-90
Driftsinstruks ........................... 91-108
Bruksanvisning .....................109-126
Driftsvejledning .....................127-144
Käyttöohje
............................. 145-162
Navodilo za uporabo.............162-180
Uputstvo za rad ....................181-198
Prevádzkový návod ..............199-216
Provozní návod.....................217-234
IInstrukcja obsługi .................235-252
Kezelési utasítás
..................253-270
Ðóêîâîäñòâî ïî ýêñïëóàòàöèè 271-288
Töö juhised ...........................289-306
Lietošanas instrukcijas
......... 307-324
Eksploatacijos instrukcijos ...325-342
Instrucciones de manejo ...... 343-360
Instruções de operação........ 361-378
Οδηγίες λειτουργίας .............379-396
Ýþletme kýlavuzu .................397-414
107140469 - 2009.07
NEPTUNE 4 FA
1
1)
Options / model variants
NEPTUNE 4 FA
Contents
Symbols used to mark
instructions
1 Important safety
instructions
2 Description
3 Before starting the cleaner
4 Control / Operation
5 Applications and methods
6 After using the cleaner
7 Maintenance
8 Troubleshooting
9 Further information
............................................................................................2
............................................................................................2
2.1 Purpose ................................................................................4
2.2 Operating elements ..............................................................5
3.1 Setting up the cleaner ..........................................................5
3.2 Set the brake ........................................................................5
3.3 Install Crank handle for high pressure hose reel
1)
................6
3.4 Fit clamp for high-pressure jet tube ......................................6
3.5 Fill up detergent tank
1)
..........................................................6
3.6 Fill up tank for Nilfisk-ALTO AntiStone ..................................6
3.7 Fill up fuel tank .....................................................................7
3.8 Connecting the high pressure hose ......................................7
3.9 Connecting the water supply ................................................8
3.10 Electrical connection ............................................................8
3.11 Antifreeze - before first use ..................................................8
4.1 Connections .........................................................................9
4.2 Switching on the cleaner ......................................................9
4.3 Pressure regulation (Tornado Lance)
1)
...............................10
4.4 Pressure regulation (VarioPress Gun)
1)
.............................. 10
4.5 Using cleaning agents ........................................................10
5.1 Techniques .........................................................................10
5.2 Some typical cleaning tasks ...............................................11
6.1 Switching off the cleaner ....................................................13
6.2 Disconnecting supply lines .................................................13
6.3 Rolling up the electrical cord and storing accessories .......13
6.4 Storing the cleaner (below 0°C) .........................................13
7.1 Maintenance plan ...............................................................14
7.2 Maintenance work ..............................................................14
8.1 Indications on Display ........................................................16
8.2 Other Faults ........................................................................17
9.1 Recycling the cleaner .........................................................18
9.2 Guarantee ..........................................................................18
9.3 EU Declaration of Conformity .............................................18
9.4 Technical data ..................................................................415
2
1)
Options / model variants
NEPTUNE 4 FA
1 Important safety instructions
Symbols used to mark
instructions
Before using the
high-pressure-
cleaner, be sure to
also read the en-
closed operating in-
structions and keep
them within reach at all times.
For your own safety
The appliance must
only be used by persons,
who have been instructed
in its correct usage and ex-
plicitly commisioned with the
task of operating it.
only be operated under su-
pervision.
not be used by children.
not be used by mentally or
physically disabled persons
Warning
Ensure that any exhaust emis-
sions are not in the vicinity of air
intakes.
This machine shall only be used
with cleaning chemicals supplied
or recommended by Nilfi sk-ALTO.
The use of other cleaning chemi-
cals may adversely affect the
safety of the machine.
General
Use of the high-pressure cleaner
is subject to the applicable local
regulations.
Besides the operating instruc-
tions and the binding accident
prevention regulations valid in the
country of use, observe recog-
nized regulations for safety and
proper use.
Do not use any unsafe work
techniques.
Do not tie the trigger handle
open.
Transport
Transport of the high-pressure
cleaner is easy on its large
wheels.
For safe transport in and on ve-
hicles we recommend preventing
the equipment from sliding and
tilting. Secure it with tie-downs
and apply the parking brake on
the castor wheel.
For transport at temperatures
around or below freezing 0°C
(32°F), anti-freeze should be
drawn into the pump beforehand
(see chapter 6).
Before starting the cleaner
If your 3-phase cleaner was
supplied without a plug, have
it fi tted with a suitable 3-phase
plug with ground, by a qualifi ed
electrician.
Before use, check that the high-
pressure cleaner is safe and in
proper condition.
Regularly check whether the
power cord is damaged or shows
signs of ageing.
Use the high-pressure cleaner
only when the power cord is in
a safe condition. (risk of electric
shock using damaged cord!).
Check the rated voltage of the
high-pressure cleaner before
connecting it to the mains power
supply. Ensure that the voltage
shown on the rating plate cor-
responds to the voltage of the
power supply.
We strongly recommend that the
power supply to the high pres-
sure cleaner be connected via a
residual current circuit breaker.
This device stops the supply of
electricity if the leakage current
to the ground exceeds 30 mA for
30 ms or it has an ground tester
circuit.
Please observe the regulations
and provisions applicable in your
area. Before putting the high-
pressure cleaner into service,
Safety instruc-
tions in these op-
erating instruc-
tions which must
be observed to
prevent risks to
persons are marked with this
danger symbol.
This symbol is used
to mark safety in-
structions that must
be observed to pre-
vent damage to the
machine and its per-
formance.
This indicates
tips and instruc-
tions to simplify
work and to en-
sure safe operation.
Operations marked
with this symbol
should only be car-
ried out by Nilfisk-
ALTO Service Tech-
nicians.
3
1)
Options / model variants
NEPTUNE 4 FA
carry out a visual check of all the
major components.
CAUTION!
High-pressure water jets can
be dangerous if misused. The
jet must not be directed at
persons, animals, live electri-
cal equipment or the cleaner
itself.
Wear appropriate protective
clothing and eye protection.
Do not direct the jet towards
yourself or towards other per-
sons in order to clean clothes
or footwear.
During operation of the cleaner,
recoil forces are produced at the
gunvalve and spray lance and,
when the spray lance is held at
an angle, a torque is also cre-
ated. The gunvalve and spray
lancemust therefore be held
rmly in both hands.
Do not use the cleaner when
other people without protec-
tive clothing are in the working
area.
Check that cleaning will not
result in dangerous substances
(e.g. asbestos, oil) being washed
off the object to be cleaned and
harming the environment.
Do not clean delicate parts
made of rubber, fabric, etc. with
the 0° jet. Keep some distance
between high pressure nozzle
and surface in order to prevent
the surface from damage.
Do not use the high-pressure
hose for lifting loads.
NOTE!
The maximum permissible work-
ing pressure and temperature
are printed on the high-pressure
hose.
Do not use the cleaner if the
power cord or high-pressure
hose is damaged.
Ensure adequate air circulation.
Do not cover the cleaner or oper-
ate it in inadequately ventilated
rooms!
Store the cleaner where
it will not be exposed to
frost or use antifreeze
liquid!
Never operate the cleaner with-
out water. Even brief shortages
of water result in severe damage
to the pump seals.
Water connection
This high pressure
washer is only al-
lowed to be con-
nected with the
drinking water
mains, when an appropriate
backflow preventer has been
installed, Type BA according
to EN 1717. If the back fl ow
preventer hasn’t been supplied,
one can be purchased from your
dealer. The length of the hose
between the backfl ow preventer
and the high pressure washer
must be at least 12 metres (min
diameter 3/4 inch) to absorb pos-
sible pressure peaks. Operation
by suction (for example from
a rainwater vessel) is carried
out without backfl ow preventer.
Contact your dealer for suction
set recommendations.
As soon as water has flown
through the BA valve, this water
is not considered to be drinking
water any more.
Operation
Keep cabinet and service door
closed during operation.
CAUTION!
Unsuitable extension cords
can represent a source of
danger. Always unwind cord
from the reels completely to
prevent the power cord over-
heating.
Connectors and couplings of
extension cords must be water-
tight.
Extension cords are not recom-
mended, however if necessaray
refer to the following recommen-
dations:
Cable length
m
Cross section
< 16 A > 25 A
up to 20 m
ø1.5mm² ø2.5mm²
20 to 50 m
ø2.5mm² ø4.0mm²
Do not damage the power cord
(e.g. by driving over it, pulling or
crushing it).
Disconnect the power cord by
grasping the plug only (do not pull
or tug the power cord).
CAUTION!
Unsuitable fuels (e.g. gasoline)
must not be used as they can
explode and catch fi re.
Use clean fuel only, free of mois-
ture and contamination. Contact
your dealer for fuel source and
type recommendations.
If the machine is to be operated at
fuel stations or in other potentially
hazardous areas, the machine
may only be employed outside
the hazard areas defi ned in the
German „Technical Guidelines
for Infl ammable Fluids“ applica-
ble at the point of use due to the
potential explosion hazard posed
by the burner.
If the machine is to be operated
indoors, the local building regu-
lations must be observed for the
discharge of the exhaust fumes
into the atmosphere. Ensure an
adequate supply of fresh air.
If the machine is to be connected
to a fl ue gas stack, then local
building regulations must be ob-
served. We will be glad to provide
tips for connection systems, on
request.
CAUTION!
Beware of hot water and
steam discharge up to
150
0
C when operating in
steam stage.
CAUTION!
Do not touch or cover the
exhaust. Risk of burns
and fi re.
Do not touch, cover or place
4
1)
Options / model variants
NEPTUNE 4 FA
hose or cord over the chimney.
Danger for persons, risk of
overheating and fi re.
Electrical equipment
CAUTION!
Never spray electrical equip-
ment with water: risk of elect-
trical shock and short-circuit.
The cleaner may only be con-
nected to a correctly installed
plug socket.
Switching on the cleaner may
cause voltage fl uctuations.
Voltage fl uctuations should not
occur if the impedance at the
transfer point is less than 0.15Ω.
If in doubt ask your local electric-
ity supplier.
Maintenance and repair
CAUTION!
Always remove the plug from
the power supply before clea-
ning or carrying out mainte-
nance work on the cleaner.
Carry out only the maintenance
operations described in the oper-
ating instructions. Use only origi-
nal Nilfi sk-ALTO spare parts.
Do not make any technical modi-
fications to the high-pressure
cleaner.
Ensure that the machine is regu-
larly serviced by authorized Nil-
sk-ALTO dealers in accordance
with the maintenace plan. Failure
to do so will void the warranty.
CAUTION!
High-pressure hoses, ttings
and couplings are important
for the safety of the cleaner.
Use only high-pressure parts
approved by the manufac-
turer!
The power cord must not differ
from the version specifi ed by the
manufacturer and may only be
changed by an electrician.
Please contact your local author-
ized Nilfi sk-ALTO equipment dis-
tributor for all other maintenance
or repair needs!
Testing
The cleaner conforms to the Ger-
man „Guidelines for Liquid Spray
Jet Devices“. The high-pressure
cleaner must be subjected to a
safety examination in accord-
ance with the „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices“
as required, but at least every
12 months, by an authorised
inspector.
After all repairs or modifica-
tions to electrical equipment,
the protective conductor resist-
ance, the insulation resistance
and the leakage current must
be measured. Furthermore, a
visual inspection of the mains
power cord, a voltage and current
measurement and a function test
must be carried out. Our after-
sales service technicians are
at your disposal as authorised
inspectors.
The complete „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices“
are available from the Carl Hey-
manns Verlag KG, Luxemburger
Strasse 449, 50939 Cologne or
from the appropriate associa-
tion of employers’ liability insur-
ances.
The pressure-bearing parts of
this high-pressure cleaner have
been manufactured in accord-
ance with § 9 of the German
Pressure Vessels Ordinance
and successfully subjected to a
pressure test.
Bypass valve
The pressure is reduced by
means of a "bypass valve" which
returns water to the inlet side of
the pump at a minimum pressure.
The point at which this occurs is
set and sealed at the factory and
must not be adjusted.
2 Description
2.1 Purpose
This high-pressure cleaner has
been designed for professional
use. It can be used for cleaning
agricultural and construction
equipment, stables, vehicles,
rusty surfaces, etc.
The cleaner has not been ap-
proved for cleaning surfaces
which comes into contact with
food.
Chapter 5 describes the use of
the high-pressure cleaner for
various cleaning jobs.
Always use the cleaner as de-
scribed in these operating in-
structions. Any other use may
damage the cleaner or the sur-
face to be cleaned or may result
in severe injury to persons.
5
1)
Options / model variants
NEPTUNE 4 FA
2.2 Operating elements
1 Spray lance
2 Spray lance storage
3 Control panel
4 Pressure gauge
5 Tank fi ller for fuel
6 Receptacle for service
crane and lifting ring
1)
7 Top cover release
8 Crank handle for
High pressure hose
reel
(Neptune..X)
9 High pressure hose
connection for machines
without hose reel
10 Main switch with
temperature controller
11 Detergent metering knob
1)
12 Power ON
13 Pump oil low
1)
14 Service interval due/expired
15 Nilfi sk-ALTO AntiStone low
1)
16 Fuel low
1)
17 Castor with parking brake
18 Supply water connection
19 Tank fi ller for anti-freeze
20 Tank fi ller for Nilfi sk-ALTO
AntiStone
21 Canister for detergent
22 High pressure hose
reel
(Neptune..X)
23 Cable hook
24 Grip for top cover
3 Before starting the cleaner
3.1 Setting up the cleaner
Every fuel-burning appliance,
such as pressure washers, de-
pends upon a proper mix of fuel
and air (by
weight) for proper
combustion. Therefore some
adjustment of the air regulation
to the burner may be necessary
to take account of altitude and
the resulting air pressure. This
is true whether your fuel is ‘Nat-
ural gas’, Propane or Diesel.
Your Nilfisk-ALTO hot water
pressure washer was thor-
oughly tested and adjusted for
optimum performance before
it left our factory. The factory is
located at approximately 120m
(390 ft) above sea level, and the
combustion settings are optimal
for that elevation.
If your location is higher than
1200m (3900 ft) above sea
level, your burner may require
re-adjustment for proper per-
formance and best fuel econ-
omy. Contact your Dealer or
Nilfisk-ALTO for assistance.
3.2 Set the brake
Before using the cleaner for 1.
the first time, check it care-
fully to detect any faults or
damage.
Run the machine only when 2.
it is in perfect condition.
Set the brake.3.
The slope of which the high 4.
pressure cleaner is placed
must not exceed more than
10° in any direction.
See fold-out page at front of these
operating instructions.
6
1)
Options / model variants
NEPTUNE 4 FA
3.6 Fill up tank for Nilfisk-
ALTO AntiStone
1. Fill up Nilfisk-ALTO Anti-
Stone/water softener reser-
voir with the sample bottle
provided. Nilfisk-ALTO Anti-
Stone prevents any deposits
of scale and acts at the same
time as a corrosion inhibitor.
For compatibility reasons, use
only the tested „Nilfisk-ALTO
Anti-Stone“. Order the refill pack
in good time (Order no. 8466, 6
x 1 l).
3.5 Fill up detergent tank
1)
1. Fill up detergent tank with
prediluted detergent.
Capacity see chapter 9.4 Tech-
nical Data
3.3 Install Crank handle
for high pressure hose
reel
1)
1. Pull cap of crank in arrow di-
rection.
2. Align tabs on crank with slot
in axle.
3. Put crank on axle of high
pressure hose reel.
4. Fix crank by pushing the
cap.
1.
2.
ø
Ø
STOP
3.4 Fit clamp for high-
pressure jet tube
1. Insert clamp into the
holder on the sliding
guard:
High-pressure
jet lance
1)
clamp
7
1)
Options / model variants
NEPTUNE 4 FA
3.7 Fill up fuel tank
With the machine cold:
1. Pour fuel (fuel oil EL,
or Diesel oil DIN 51 603)
into the fuel tank.
Bio-Diesel can be used, see
notes in chapter 1).
The fuel must be free from con-
tamination.
Tank capacity see chapter 9.4
Technical data.
NOTE!
At temperatures below 8° C, the fuel
oil begins to solidify (paraffin precip-
itation). This can lead to difficulties
in starting the burner. Before the
winter period either add a solidifica-
tion point / flow improver (available
from the fuel oil trade) to the fuel or
use winter diesel fuel.
3.8 Connecting the high
pressure hose
3.8.1 Machines with high
pressure hose reel
1. Put the quick connector of
the high pressure hose onto
the nipple on the axle.
3.8.2 Machines without high
pressure hose reel
1. Put the quick connector of
the high pressure hose onto
the nipple on the cleaner.
8
1)
Options / model variants
NEPTUNE 4 FA
3.9 Connecting the water
supply
1. Rinse the water supply hose
briefly in order to prevent
sand an other dirt particles
entering into the machine.
2. Connect water supply hose
to the machine.
3. Open water tap.
3.10 Electrical connection
3.11 Antifreeze - before first
use
The machine is protected with
anti-freeze from the factory.
Catch the liquid discharging at
first (approx. 5 l) for re-use in a
container.
230 V / 400 V ?
(220 V / 440 V ?)
Before connecting devices with
voltage changeover
1)
: Check that
the pre-selected voltage on the
machine corresponds with the
voltage of the electrical instal-
lation. Otherwise the electrical
devices of the machine can be
destroyed.
CAUTION!
When using cable reels:
1. Due to the risk of overheat-
ing and fire, always unwind
the power supply cord fully.
The cleaner may only be con-
nected to a correctly installed
electrical installation.
1. Observe safety instructions in
chapter 1.
2. Put the plug into the electrical
socket.
In the case of poor water quality
(sand, etc.), we recommend that a
fine water filter is fitted in the water
inlet.
NOTE!
See chapter 9.4 Technical Data for
required quantity of water and water
pressure.
In order to comply with national
regulations and those of the water
supply companies, it must be
ensured that water cannot ow
back if the pressure in the water
mains falls below atmospheric
pressure.
We recommend the use of a textile-
reinforced water hose with a nomi-
nal diameter of min. 3/4" (19 mm).
9
1)
Options / model variants
NEPTUNE 4 FA
4 Control / Operation
A
C
B
4.1 Connections
4.1.1 Connecting the spray
lance to the spray gun
1. Pull the blue quick-release
grip (A) of the spray gun
backwards.
2. Insert the nipple of the spray
lance (B) into the quick-re-
lease connection and release
it.
3. Pull the spray lance (or other
accessory) forwards to check
that it is securely attached to
the spray gun.
NOTE!
Always remove any dirt from the
nipple before connecting the spray
lance to the spray gun.
4.2 Switching on the
cleaner
4.2.1 Cold water operation /
Hot water operation (up
to 100°C)
1. Move main switch into posi-
tion ‘Cold Water’ (A).
The control electronics system
performs a self-test, all the LEDs
light up once.
The motor starts.
lights up.
2. Move main switch into posi-
tion ‘Hot Water’ (B) and se-
lect the temperature.
3. Unlock the spray gun and ac-
tuate it.
The burner switches on.
In case of interruptions in work:
Also be sure to insert the safety
catch even during short inter-
ruptions in work (see Fig. in sec-
tion 6.1)
IMPORTANT!
In the case of appliances with a
hose reel:
In hot water mode, unwind the
high-pressure hose fully from the
hose reel, as otherwise the hose
reel may become warped due to
the effects of the heat.
OFF
°C
°F
20
6
8
40
104
60
140
80
100
2
12
140
284
A
B
1. Open cover.
2. Turn the twist grip on the
safety control block com ple-
te ly to the left (anti clock wise
direction).
3. Turn the main switch into po-
sition ‘Hot Water’.
4. Select temperature (over
100°C).
For special applications: re-
place the standard nozzle with
the steam spray nozzle (acces-
sory).
4.2.2 Steam operation (over
100°C)
1)
Beware of hot water and
steam discharge up to
150°C when operating in
steam stage.
10
1)
Options / model variants
NEPTUNE 4 FA
4.3 Pressure regulation
(Tornado Lance)
1)
1. Turn the twist grip on the spray
unit:
High pressure =
clockwise (+) for high pres-
sure
Low pressure =
anticlockwise (–) for low pres-
sure.
5 Applications and methods
Effi cient high pressure cleaning is achieved by following a few guide-
lines, combined with your own personal experience of specifi c clean-
ing tasks. Accessories and detergents, when correctly chosen, can
increase the effi ciency of your pressure washer. Here is some basic
information about cleaning.
5.1 Techniques
4.5 Using cleaning agents
1. Set the desired concentra-
tion of cleansing agent at the
cleansing agent dosing facil-
ity.
2. Spray the object to be
cleaned.
3. Allow the cleaning agent to
work, depending on the de-
gree of soiling. Then rinse off
with the high pressure spray
jet.
4.4 Pressure regulation
(VarioPress Gun)
1)
,
For safety reasons,
never tie back or
wedge open the
trigger of the spray
gun in open
position during
operation. The trigger must be free
to close when released, thus
interrupting the ow of the water.
1. Turn the twist grip on the
spray unit:
Water volume
(–) (+)
min. max.
For special applications (e.g. dis-
infection) the exact detergent con-
centration has to be determined by
measuring cup. For water through-
put of the machine see chapter 9.4
technical data.
,
CAUTION!
Never allow cleaning agent to dry
on the surface to be cleaned. The
surface may be damaged.
0
11
1)
Options / model variants
NEPTUNE 4 FA
5.1.1 Soaking
Encrusted or thick layers of dirt can be loosened or softened up
by a period of soaking. This is for example an ideal method within
agriculture – for example, within pig sties. The ideal soaking method
can be achieved via use of foam or simple alkaline detergent. Let
the product lie on the dirty surfaces for around 30 minutes before
pressure washing. The result will be a much quicker high pressure
cleaning process.
5.1.2 Detergent and Foam
Foam or detergent should be applied onto dry surfaces so that the
chemical product is in direct contact with the dirt. Detergents are
applied from bottom to top, for example on a car bodywork, in order
to avoid “super clean” areas, where the detergent collects in higher
concentration and streams downwards. Let the detergent work for
several minutes before rinsing before rinsing but never let it dry on
the surface being cleaned.
5.1.3 Temperature
Detergents are more effective at higher temperatures. Greases, oils
and fats can be broken down more easily at higher temperatures also.
Proteins can be cleaned at temperatures of around 60°C. Oils, traffi c
lm around 70°C, and grease can be cleaned at 80°C - 90° C.
5.1.4 Mechanical Effect
In order to break down tough layers of dirt, additional mechanical
effect may be required. Special lances and rotary or wash brushes
offer this supplementary effect that cuts through dirt.
5.1.5 High Water Flow or
High Pressure
High pressure is not always the best solution and high pressure
may damage surfaces. The cleaning effect also depends upon water
ow. Pressure levels of around 100 bar may be suffi cient for vehicle
cleaning (in association with hot water). Higher fl ow levels give the
possibility to rinse and fl ush away large amounts of dirt easily.
5.2 Some typical cleaning tasks
5.2.1 Agriculture
Task Accessories Method
Stables
Pig Pens, Sties
Cleaning of walls,
floors and equip-
ment
Disinfectant
Chemical Foam Injec-
tors
Foam lance
Powerspeed lance
Floor Cleaner
Detergents
Universal
Alkafoam
Disinfectant
DES 3000
1. Soaking – apply foam to all surfaces (bottom to top)
and wait for approx. 30 minutes.
2. Remove the dirt from surfaces with the high pressure
lance or chosen accessory. Again, clean from bottom
to top on vertical surfaces.
3. To fl ush away large quantities of dirt, change to low
pressure mode and use the higher fl ow to push away
the dirt.
4. Use recommended disinfectant products and methods
to ensure hygiene. Apply DES 3000 disinfectant once
the surfaces are perfectly clean.
Machinery
Tractors
ploughs etc.
Detergent injection
Powerspeed lances
Curved lances and un-
derchassis washers
Brushes
1. Apply detergent to vehicle or equipment surfaces in
order to soften up dirt and grime. Apply from bottom
to top.
2. Proceed with cleaning using the high pressure lance.
Clean again from bottom to top. Use accessories to
clean in diffi cult to reach places.
3. Clean fragile areas such as motors, rubber at lower
pressure levels to avoid damage.
12
1)
Options / model variants
NEPTUNE 4 FA
5.2.3 Buildings and Equipment
These are merely several examples of cleaning tasks that can be solved by a pressure washer in asso-
ciation with accessories and detergents. Each cleaning task is different. Please consult your local dealer
or ALTO representative in order to discuss the best solution for your own cleaning tasks.
5.2.2 Vehicle
Task Accessories Method
Vehicle bodywork Standard lance
Detergent injection
Curved lances and un-
derchassis washers
brushes
Detergents
Active Shampoo
Active Foam
Sapphire
Super Plus
Active Wax
Allosil
RimTop
1. Apply detergent to vehicle or equipment surfaces in
order to soften up dirt and grime. Apply from bottom
to top. In cases of particularly dirty vehicles, pre-spray
with a product such as Allosil in order to remove traces
of insects etc, then rinse at low pressure and apply
normal car cleaning detergent. Let detergents settle
for 5 minutes before cleaning off. Metallic surfaces can
be cleaned using RimTop.
2. Proceed with cleaning using the high pressure lance.
Clean again from bottom to top. Use accessories to
clean in diffi cult to reach places. Use brushes in order
to add a mechanical cleaning effect. Short lances can
help for cleaning of motors and wheel arches. Curved
lances or undercarriage washers can be valuable for
the cleaning of car underchassis and wheel arches.
3. Clean fragile areas such as motors, rubber at lower
pressure levels to avoid damage.
4. Apply a liquid wax using the pressure washer in order
to protect the bodywork from pollution.
Task Accessories Method
General surfaces
Metallic equipment
Foam injectors Stand-
ard lance
Curved lances
Tank cleaning
head
Detergents
Intensive
J25 Multi
Combi Active
Alkafoam
Disinfectant
DES 3000
1. Apply thick foam over the surfaces to be cleaned. Apply
on dry surfaces. Apply from top to bottom on vertical
surfaces. Let the foam act for up to 30 minutes for the
optimal effect.
2. Proceed with cleaning using the high pressure lance.
Use applicable accessories. Use high pressure to
dislodge large amounts of incrusted dirt or grime.
Use lower pressure and high water volume in order
to rapidly fl ush away loose dirt and rinse surfaces.
3. Apply DES 3000 disinfectant once the surfaces are
perfectly clean.
Areas covered by amounts of loose dirt, such as animal
remains in slaughterhouses, can be removed by using
high water fl ow to fl ush away the dirt to evacuation pits
or drains.
Tank cleaning heads can be used to clean barrels, vats,
mixing tanks etc. Cleaning heads may be hydraulically or
electrically powered and give the possibility for automatic
cleaning without a constant user.
Rusted or dam-
ages surfaces prior
to treatment
Wet Sandblasting
equipment
1. Connect the sandblasting lance to the pressure
washer and place the suction tube in the sand.
2. Always wear protective equipment during sandblast-
ing.
3. Spray the surfaces to be treated with the mix of water
and sand. Rust, paint etc will be stripped off.
13
1)
Options / model variants
NEPTUNE 4 FA
6 After using the cleaner
6.1 Switching off the
cleaner
1. Turn the main switch to posi-
tion „OFF“.
2. Close water tap.
3. Squeeze the spray gun han-
dle until the cleaner is de-
pressurised.
4. Lock the safety catch on the
spray gun.
6.2 Disconnecting supply
lines
1. Close water tap.
2. Squeeze the spray gun han-
dle until the cleaner is de-
pressurised.
3. Lock the safety catch on the
spray gun.
6.3 Rolling up the electrical
cord and storing
accessories
Risk of tripping!
To prevent accidents, always
carefully roll up the electrical
cord.
1. Wind up the cord
2. Wind up the high pressure
hose.
3. Place the spray lance into
the spray lance storage.
4. Switch off the cleaner.
5. Remove the water hose from
the cleaner.
6. Pull out the plug from the
electrical socket.
6.4 Storing the cleaner
(below 0°C)
Store the cleaner in a dry room
without danger of frost or protect
as below:
1. Remove the water inlet hose
from the cleaner.
2. Remove the spray lance.
3. Switch on the cleaner with
the main switch in position
"Cold Water".
4. Operate the spray gun.
5. Gradually pour antifreeze
(approx. 5 litres) into the wa-
ter tank (A).
6. During suction operate the
spray gun two or three times.
7. The machine is protected
against frost when antifreeze
solution emerges from the
spray gun.
8. Lock the safety catch on the
spray gun.
9. Switch off the cleaner.
10. To avoid any risks, store
the cleaner temporarily in a
heated room before using it
again.
11. When the machine is put into
service again, the antifreeze
solution can be collected and
stored for future use.
A
A
14
1)
Options / model variants
NEPTUNE 4 FA
7 Maintenance
7.1 Maintenance plan
7.2 Maintenance work
7.2.1 Water filters
A water fi lter is fi tted on the water
inlet to prevent large particles of
dirt from entering into the pump.
1. Unscrew quick coupling.
2. Remove fi lter with tool and
clean it.
Weekly
After the fi rst 50
operating hours
Every six
months or
500 operating
hours
As
required
7.2.1 Water fi lters
Q
7.2.2 Oil fi lter
Q
7.2.3 Checking the pump oil quality
Q
7.2.4 Changing the pump oil
QQ
7.2.5 Emptying the fuel oil tank
Q
7.2.2 Maintenance of fuel
filter
Open hose clips1.
Replace fuel fi lter2.
Close hose clips3.
Dispose the cleaning solu-4.
tion/damaged filter in ac-
cordancewith the disposal-
regulations.
15
1)
Options / model variants
NEPTUNE 4 FA
7.2.4 Changing the pump oil
1. Unscrew the oil drain plug
(A) on the pump housing and
dispose of the old oil in ac-
cordance with the disposal
regulations.
2. Check the drain plug gasket
and screw in the plug again.
3. Fill with oil and close the oil
filler plug.
Oil grade and capacity see
chapter ‘9.4 Technical Data’.
7.2.3 Checking the pump oil
quality
1. Check colour of pump oil.
If the oil has a grey or white
shade, change the oil (see
chapter 7.2.4)
2. Top up cold pump with fresh
oil if necessary.
Oil type see chapter 9.4
Technical Data.
7.2.5 Flame sensor
1)
1. Remove the sensor and
clean with a soft cloth.
2. Ensure that the sensor is
correctly seated when install-
ing again - the symbols must
face upwards.
A
16
1)
Options / model variants
NEPTUNE 4 FA
Continued
8.1 Indications on Display
8 Troubleshooting
Indication lights Cause Remedy
>
>
Constant light
- The appliance is ready for
operation
When switching on, all the
LEDs light up once before the
motor is switched on
Flashing light
- Flow sensor fault
- Water tap closed or water
shortage
- Detergent tank empty
- Pressure regulation on
the safety control block or
VarioPress-lance
1)
set to low
water volume
- Machine scaled
>
>
>
>
>
Contact Nil sk-ALTO Service
Cold water operation possible
Required volume ow and pres-
sure see chapter 9.4 Technical
Data
Top up detergent tank or set de-
tergent metering to “OFF“
Turn the twist grip on safety con-
trol block or VarioPress lance
1)
to
higher water volume (see chapter
4.4)
Contact Nil sk-ALTO Service
> Constant light
- Fuel shortage
>
>
Top up fuel
Cold water operation is possible
> Flashing light
- Ni sk-ALTO AntiStone short-
age
> Top up Nil sk-ALTO AntiStone
>
>
Constant light
- Service interval has expired
Flashing light
- Service interval due in 20
hours
>
>
Contact Nil sk-ALTO Service
Contact Nil sk-ALTO Service
> Constant light
- Pump oil low
> Top up pump oil
> Flashing light (simultaneously)
- Leakage or inadmissible op-
erating condition by short-time
operation
- Spray gun leaking
- High pressure hose, coupling
or line system leaking
- Detergent tank empty
- Water inlet lter dirty
- High-pressure pump drawing
in air
>
>
>
>
>
>
After three times of short-time op-
eration the manchine switches off.
Reset: Turn main switch to posi-
tion “OFF“, then start again. Keep
spray gun pressed for longer than
3 seconds. If a leak occurs caus-
ing the machine to start and stop
brie y 3 times, then the machine
will switch off.
Check Spray gun
Replace high pressure hose,
retighten screw ttings
Top up detergent tank or set de-
tergent metering to “OFF“
Clean lter (see chapter 7.2.1)
Repair leaks
17
1)
Options / model variants
NEPTUNE 4 FA
8.2 Other Faults
Fault Cause Remedy
not ON
> Plug not connected to the
electrical plug socket
Put the plug into the electrical
socket.
Check fuse (see chapter 9.4 Techni-
cal Data)
Pressure too low > High pressure nozzle worn
out
Replace nozzle
> Pressure regulation set to low
pressure or VarioPress-lance
1)
set to low water volume.
Turn the twist grip on safety control
block clockwise (+) or set VarioPress-
lance
1)
to higher water volume (see
chapter 4.4)
Machine is running with
pulsating pressure and
makes knocking noise
> Pump has drawn in air as the
detergent tank is empty
Close detergent valve. Remove
lance from gun. Operate spray gun
and let machine run until air in pump
is gone and the machine is running
normally/calm again.
No detergents drawn in > Detergent tank empty Top up detergent tank
> Dirt in detergent tank Clean detergent tank
> Suction valve at cleaning
agent inlet soiled
Remove suction valve and clean or
replace
Burner soots > fuel contamination
Contact Alto Service
> Burner sooted or adjustment
incorrect
>
>
Flashing light (alternately)
- Motor overheated
- Machine overheated
>
>
Turn main switch in position
“OFF“, let the machine cool
down
Remove/disconnect exten-
sion cable
Possible phase failure; have
electrical connection checked
Contact Nil sk-ALTO Service
slow
rapid
> Flashing light
- Flame sensor sooted
- Ignition or fuel system failure
>
>
Clean ame sensor (see chapter
7.2.5)
Contact Nil sk-ALTO Service
Cold water operation possible
18
1)
Options / model variants
NEPTUNE 4 FA
9 Further information
9.1 Recycling the cleaner
Make the old cleaner unusable im-
mediately.
1. Unplug the cleaner and cut the
power cord.
Do not discard of electrical appli-
ances with household waste.
As specified in European Directive
2002/96/EC on old electrical
and electronic appliances, used
electrical goods must be col-
lected separately and recycled
ecologically. Contact your local
authorities or your nearest deal-
er for further information.
9.2 Guarantee Our general conditions of business
are applicable with regard to the
guarantee. Subject to change as a
result of technical advances.
The guarantee is invalidated if the
machine is not operated in ac-
cordance with these instructions
or otherwise abused. The guaran-
tee is invalidated if the machine is
not serviced as described.
9.3 EU Declaration of
Conformity
EU Declaration of Conformity
Product:
High Pressure Cleaner
Type:
NEPTUNE 4
Description:
230 V 1~, 50 Hz / 400 V 3~, 50 Hz / IP X5
The design of the unit corresponds to the
following pertinent regulations:
EC Machine Directive 2006/42/EC
EC Low-voltage Directive 2006/95/EC
EC EMC Directive 2004/108/EC
Applied harmonised standards:
EN ISO 12100-1, EN ISO 12100-2, EN 60335-2-79
EN 55014-1, EN 55014-2, EN 61000-3-2
Applied national standards and technical
specifi cations:
DIN EN 60335-2-79
Nilfi sk-Advance A/S
Industrivej 1
DK-9560 Hadsund
Dipl. Ing. Wolfgang Nieuwkamp
Tests and approvals
Hadsund, 01.06.2009
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418

Nilfisk-ALTO NEPTUNE 4 FA Operating Instructions Manual

Typ
Operating Instructions Manual

v iných jazykoch