Weller WFE 2ES Používateľská príručka

Typ
Používateľská príručka
WFE 2ES
Betriebsanleitung - Operating Instructions - Mode dèmploi - Istruzioni per lùso - Manual de uso -
Manual do utilizador - Gebruiksaanwijzing - Instruktionsbok - Betjeningsvejledning - Käyttöohjeet -
Οδηγίες Λειτουργίας- Kullanım kılavuzu - Návod k použití - Instrukcja obsługi - Üzemeltetési utasítás
Návod na používanie - Navodila za uporabo - Kasutusjuhend - Lietosanas instrukcija -
Naudojimo instrukcija
WFE 2ES Operating Instructions I
The data specified above only serves
to describe the product. No statements
concerning a certain condition or suitability for
a certain application can be derived from our
information. The given information does not
release the user from the obligation of own
judgement and verification. It must be
remembered that our products are subject to a
natural process of wear and aging.
© This document, as well as the data,
specifications and other information set forth
in it, are the exclusive property of
Weller Tools GmbH. Without their consent it
may not be reproduced or given to third
parties. Subject to modifications.
Printed in Germany.
09.2011
Deutsch
DE
English
EN
Français
FR
Italiano
IT
Español
ES
Português
PT
Nederlands
NL
Svenska
SV
Dansk
DK
Suomi
FI
Eλληvık
GR
Türkçe
TR
Česky
CZ
Polski
PL
Magyar
HU
Slovensky
SK
Slovenščina
SL
Saksa keel
EE
Lietuviškal
LV
Vāciski
LT
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Betriebsanleitung
DE
WFE 2ES
WFE 2ES
Geräteübersicht
1 Öffnung für Abluft
2 Filtergehäuse
3 Rohrstutzen
Vakuumanschluss
4 Spannschlösser
5 Netzschalter
6 Sicherung
7 Netzanschluss
8 Turbinengehäuse
9 Verschlussstopfen
10 Feinstaubfilter
11 Kompaktfilter
12 Turbinenplatte
10
11
12
8
2
WFE 2ES 3-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Inhalt
1
Zu dieser Anleitung .................................................................... 3
2 Zu Ihrer Sicherheit ..................................................................... 4
3 Lieferumfang WFE 2ES ............................................................. 4
4 Gerätebeschreibung .................................................................. 5
5 Gerät in Betrieb nehmen ............................................................ 5
6 Lötrauch absaugen .................................................................... 6
7 Filter wechseln ........................................................................... 7
8 Fehlermeldungen und Fehlerbehebung..................................... 8
9 Zubehör ..................................................................................... 8
10 Entsorgung ................................................................................ 8
11 Garantie ..................................................................................... 8
1 Zu dieser Anleitung
Wir danken Ihnen für das mit dem Kauf der Weller WFE 2ES
erwiesene Vertrauen. Bei der Fertigung wurden strengste
Qualitätsanforderungen zugrunde gelegt, die eine einwandfreie
Funktion des Gerätes sicherstellen.
Diese Anleitung enthält wichtige Informationen, um die
Lötrauchabsaugung WFE 2ES sicher und sachgerecht in Betrieb zu
nehmen, zu bedienen, zu warten und einfache Störungen selbst zu
beseitigen.
Z Lesen Sie diese Anleitung und die beiliegenden
Sicherheitshinweise vor Inbetriebnahme des Gerätes vollständig
bevor Sie mit der Lötrauchabsaugung WFE 2ES arbeiten.
Z Bewahren Sie diese Anleitung so auf, dass sie für alle Benutzer
zugänglich ist.
1.1 Berücksichtigte Richtlinien
Die Weller Lötrauchabsaugung WFE 2ES entspricht den Angaben
der EG Konformitätserklärung mit den Richtlinien 2004/108/EG und
2006/95/EG.
1.2 Mitgeltende Dokumente
Betriebsanleitung der Lötrauchabsaugung WFE 2ES
Begleitheft Sicherheitshinweise zu dieser Anleitung
4-8 WFE 2ES
2 Zu Ihrer Sicherheit
Die Lötrauchabsaugung WFE 2ES wurde entsprechend dem
heutigen Stand der Technik und den anerkannten
sicherheitstechnischen Regeln hergestellt. Trotzdem besteht die
Gefahr von Personen- und Sachschäden, wenn Sie die
Sicherheitshinweise im beiliegenden Sicherheitsheft sowie die
Warnhinweise in dieser Anleitung nicht beachten. Geben Sie die
Lötrauchabsaugung WFE 2ES an Dritte stets zusammen mit der
Betriebsanleitung weiter.
2.1 Bestimmungsgemäßer Gebrauch
Verwenden Sie die Lötrauchabsaugung WFE 2ES ausschließlich
gemäß dem in der Betriebsanleitung angegebenen Zweck der
Lötrauchabsaugung von Arbeitsflächen unter den hier angegebenen
Bedingungen. Der bestimmungsgemäße Gebrauch der
Lötrauchabsaugung WFE 2ES schließt auch ein, dass
Sie diese Anleitung beachten,
Sie alle weiteren Begleitunterlagen beachten,
Sie die nationalen Unfallverhütungsvorschriften am Einsatzort
beachten.
Für eigenmächtig vorgenommene Veränderungen am Gerät wird
vom Hersteller keine Haftung übernommen.
3 Lieferumfang WFE 2ES
WFE 2ES inkl. Filter
Anschlusskabel
Betriebsanleitung
Heft Sicherheitshinweise
WFE 2ES 5-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
4 Gerätebeschreibung
Die Weller WFE 2ES ist eine Lötrauchabsaugung für den Einsatz als
Arbeitsflächenabsaugung für folgende Eigenschaften und
Funktionen konzipiert:
Sie besitzt eine leistungsstarke wartungsfreie Turbine und ist
bestens geeignet für den industriellen Dauerbetrieb.
Individuelle Gestaltung des Rohrsystems mit max. 2 Rohrstutzen.
3-Stufen-Filter (Feinstaub-, Schwebstoff- und Aktivkohlefilter)
abgestimmt auf die standardmäßige Zusammensetzung von
Lötrauch.
Hohe Filtereffizienz: Beim Einsatz von geprüften
Schwebstofffiltern der Klasse H12 liegt nach EN 1822 der
Abscheidgrad des Filtersatzes im Auslieferzustand bei 99,5 %, bei
einer Partikelgröße von 0,18 µm (Werte gelten nur bei Benutzung
von Orginalteilen).
4.1 Technische Daten WFE 2ES
A
bmessungen L x B x H (mm): 320 x 320 x 395
Gewicht 9 kg
Spannung 230 V, 50Hz
120 V, 60 Hz
Elektr. Leistung 115 VA
Max. Vakuum 1800 Pa
Max. Fördermenge 220 ㎥
/
h
Feinstaubfilter Stufe 1: Feinstaubfilter F5 nimmt 40-60 %
Feinstaub > 1 mm au
f
.
Kompaktfilter Stufe 2+3: Schwebstofffilter Klasse H12
(99,5 % bei Partikel bis ca. 0,18 µm) ist
kombiniert mit einem Aktivkohlefilte
r
.
5 Gerät in Betrieb nehmen
Achten Sie beim Aufstellen des Gerätes darauf, dass die Abluft
ungehindert aus der Abluftöffnung befördert werden kann.
1. Das Gerät sorgfältig auspacken.
2. Lötrauchabsaugung WFE 2ES über einen
- flexiblen Absaugschlauch
oder
- direkt mit dem Vakuumrohrsystem verbinden.
3. Vor Inbetriebnahme Netzspannung mit der Angabe auf dem
Typschild überprüfen.
4. Bei korrekter Netzspannung das WFE 2ES mit dem Netz
verbinden.
5. Gerät am Netzschalter (7) einschalten.
6-8 WFE 2ES
6 Lötrauch absaugen
WARNUNG!
Giftige Gase
Der Unterdruck des WFE 2ES ist für die Direktabsaugung nicht
ausreichend. Beim Löten entstehen giftige Gase welche
ungefiltert zu Gesundheitsschäden führen.
Z Verwenden Sie das WFE 2ES nur zur
Flächenlötrauchabsaugung.
Löten oder Schweißen von Lackdrähten
Verwenden Sie beim Löten und Schweißen von Lackdrähten die
standardmäßige Filtermatte F5 und einen Feinstaubfilter der
Klasse F7.
Absaugen von Klebedämpfen
Verwenden Sie beim Absaugen von Klebedämpfen einen
Breitbandgasfilter (ohne Schwebestofffilter).
Absaugen beim Löten und Schweißen
1. Filter auf Eignung und Einsatzfähigkeit überprüfen.
2. Absaugschlauch am Vakuumanschluss (3) des WFE 2ES
anschließen.
3. Absaugschlauch positionieren und fixieren.
4. WFE 2ES einschalten und absaugen.
WARNUNG!
Selbstentzündung der Aktivkohle
Durch hohe Schadgaskonzentration kann es zu einer starken
Erwärmung der Aktivkohle kommen, die zur Selbstentzündung
des Filters führen kann.
Z Betreiben Sie das Gerät vor dem Abschalten für mehrere
Minuten mit schadgasfreier Luft.
5. Nach dem abgeschlossenen Löt-/Klebevorgang
Gerät 5 min schadgasfrei betreiben.
6. Gerät abschalten
WFE 2ES 7-8
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
7 Filter wechseln
WARNUNG!
Ungefilterte Schadstoffe und Gase
Ein übersättigter Aktivkohlefilter nimmt keine Schadstoffe und
Gase mehr auf. Die Gase und Schadstoffe werden ungefiltert
wieder an die Umgebung abgegeben.
Z Halten Sie die empfohlenen Filterwechselintervalle ein.
Hinweis Verschiedene Flussmittel, Flussmittelanteile sowie
unterschiedliche Staubanteile der abgesaugten Luft können die
Lebensdauer des Filters wesentlich reduzieren.
Deshalb müssen Sie regelmäßig den Filter überprüfen und ggf.
wechseln.
Empfehlung zum Filterwechsel:
Z Bei Einschicht Betrieb den Vorfilter (=Feinstaubfilter) alle 10
Tage überprüfen und bei starker Verunreinigung auswechseln.
Z Kompaktfilter nach dem 6. – 8. Vorfilterwechsel austauschen.
Filter ausbauen:
1. Netzstecker (7) vom Netz trennen.
2. Spannschlösser (4) zwischen Turbinengehäuse (8) und
Filtergehäuse (2) öffnen.
3. Filtergehäuse (2) abheben.
4. Verunreinigten Feinstaubfilter (10) aus Kompaktfilter (11)
entnehmen
oder
Verunreinigten Kompaktfilter (11) entnehmen.
Hinweis
Entsorgen Sie die verschmutzten Filter als Sondermüll nach den
Vorschriften des Verwendungslandes.
Neuen Filter einbauen:
5. Kompaktfilter (11) einlegen (Durchflussrichtung beachten).
6. Feinstaubfilter (10) in den Kompaktfilter (11) einlegen.
7. Filtergehäuse (2) schließen
8. Spannschlösser (4) schließen.
9. Datum des Filterwechsels auf Wartungslabel notieren und am
Gehäuse gutsichtbar anbringen.
10. Netzstecker (7) einstecken.
Das Gerät ist nun wieder betriebsbereit.
8-8 WFE 2ES
8 Fehlermeldungen und Fehlerbehebung
Störung Mögliche Ursache Maßnahmen zur Abhilfe
Fehlende Absaugleistung
Rohrsystem undicht
Filter verschmutzt
Rohrsystem abdichten
Filter wechseln
WFE 2ES läuft nicht an
Thermische Abschaltung WFE 2ES abkühlen lassen
Nach ca. 3h wieder einschalten
Schwebstofffilter zu schnell
verschmutzt
Kein Vorfilter eingesetzt Vorfilter einsetzen
F7 Filter einsetzen
Vorabscheider einsetzen (bei
hohem Feststoffanteil)
9 Zubehör
T005 36 571 99 Set KIT1WF Trichter für WFE 2 Flächenabsaugung
T005 36 572 99 Set KIT1WF Düsen für WFE 2 Flächenabsaugung
T005 87 358 62 Filtergehäuse
T005 87 627 56 Absaugschlauch flexible Ø 60 (5 m)
T005 87 627 01 Filterset H12 mit 10 Vorfilter F5
besteht aus: HEPA Filter H12, Breitbandgasfilter
(10 % Aktivkohle)
T005 87 627 03 Feinstaubfilter F5 (10 St.)
T005 87 627 04 Gehäuseoberteil
Feinstaubfilter für Kompaktfilter
T005 87 359 36 Kompaktfilter HEPA H13+Gasfilter
T005 87 359 37 Feinstaubfilter F5 (10 St.)
T005 87 359 38 Feinstaubfilter F7 (10 St.)
10 Entsorgung
Entsorgen Sie ausgetauschte Geräteteile, Filter oder alte Geräte
gemäß den Vorschriften Ihres Landes.
11 Garantie
Die Mängelansprüche des Käufers verjähren in einem Jahr ab
Ablieferung an ihn. Dies gilt nicht für Rückgriffsansprüche des
Käufers nach §§ 478, 479 BGB.
Aus einer von uns abgegebenen Garantie haften wir nur, wenn die
Beschaffenheits- oder Haltbarkeitsgarantie von uns schriftlich und
unter Verwendung des Begriffs „Garantie“ abgegeben worden ist.
Technische Änderungen vorbehalten!
Die aktualisierten Betriebsanleitungen finden Sie unter
www.weller-tools.com.
EN
FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Operating instructions
WFE 2ES
WFE 2ES
Equipment overview
1 Opening for exhaust air
2 Filter housing
3 Vacuum connection pipe
nozzle
4 Turnbuckles
5 Mains switch
6 Fuse
7 Mains connection
8 Turbine housing
9 Bung
10 Fine dust filter
11 Compact filter
12 Turbine plate
10
11
12
8
2
WFE 2ES 3-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Contents
1
About these instructions ............................................................ 3
2 For your safety ........................................................................... 4
3 Scope of delivery WFE 2ES ...................................................... 4
4 Device description ..................................................................... 5
5 Starting up the device ................................................................ 5
6 Extracting soldering smoke ........................................................ 6
7 Changing filter ............................................................................ 7
8 Fault messages and fault elimination ........................................ 8
9 Accessories ............................................................................... 8
10 Disposal ..................................................................................... 8
11 Warranty .................................................................................... 8
1 About these instructions
Thank you for placing your trust in our company by purchasing the
Weller WFE 2ES. Production was based on stringent quality
requirements which guarantee the perfect operation of the device.
These instructions contain important information for safe and correct
initial operation of the soldering fume extraction device WFE 2ES,
including continued operation, maintenance and self-correction of
simple faults.
Z Read this Operating Manual and the enclosed Safety Instructions
completely prior to initial operation of the device and before
starting work with the soldering fume extraction device WFE 2ES.
Z Ensure that these instructions are accessible to all users.
1.1 Applied directives
The Weller soldering fume extraction device WFE 2ES complies with
the specifications of the EC Declaration of Conformity based on
Directives 2004/108/EC and 2006/95/EC.
1.2 Further applicable documentation
Operating instructions for the soldering fume extraction
device WFE 2ES
Safety information booklet accompanying these instructions
4-8 WFE 2ES
2 For your safety
The soldering fume extraction device WFE 2ES has been
manufactured in accordance with state-of-the-art technology and the
recognised technical safety regulations. There is nevertheless the
risk of personal injury and damage to property if you fail to observe
the safety information set out in the accompanying booklet and the
warnings given in these instructions. If the soldering fume extraction
device WFE 2ES is passed on to third parties, always hand over the
operating instructions as well.
2.1 Specified use
Always use the soldering fume extraction device WFE 2ES
exclusively for the purpose specified in these operating instructions,
namely the soldering fume extraction from working surfaces under
the conditions specified here. Specified use of the soldering fume
extraction device WFE 2ES also includes
observance of this Operating Manual,
you read and follow all additional accompanying documents,
observance of the locally applicable accident prevention
regulations.
The manufacturer shall not be liable for damage resulting from
unauthorised alterations to the machine.
3 Scope of delivery WFE 2ES
WFE 2ES incl. filter
Connecting cable
Operating instructions
Safety information booklet
WFE 2ES 5-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
4 Device description
The Weller WFE 2ES is designed as a soldering fume extraction
device for working surface extraction for the following properties and
functions:
It has a powerful maintenance-free turbine and is perfectly
suitable for continuous operation in industry.
Individual arrangement of the pipe system with max. 2 pipe
nozzles.
3-stage filter (fine dust, HEPA filter and activated carbon filter)
tuned to the standard composition of soldering smoke.
High filter efficiency: when using tested HEPA filters of class H12,
according to EN 1822 the filtration efficiency of the filter set in
delivery condition is 99.5 %, at a particle size of 0.18 µm (values
apply only if original parts are used).
4.1 Technical data WFE 2ES
Dimensions L x W x H (mm): 320 x 320 x 395
Weight 9 kg
Voltage 230 V, 50 Hz
120 V, 60 Hz
Electr. powe
r
115 VA
Max. vacuum 1800 Pa
Max. conveying
capacity
220 ㎥/h
Fine dust filter Stage 1: fine dust filter F5 absorbs
40-60 % fine dust > 1 mm.
Compact filter Stages 2+3: HEPA filter class H12 (99.5 %
with particle up to approx. 0.18 µm) is
combined with an activated carbon filter.
5 Starting up the device
When installing the device, ensure that the exhaust air can be
conveyed unobstructed out of the exhaust air opening.
1. Carefully unpack the device.
2. Connect the soldering fume extraction device WFE 2ES using a
- flexible extraction hose
or
- directly with the vacuum pipe system.
3. Prior to commissioning, check that the mains voltage matches the
specifications on the nameplate.
4. If the mains voltage is correct, connect the WFE 2ES to the
mains.
5. Switch on the device at the mains power switch (7).
6-8 WFE 2ES
6 Extracting soldering smoke
WARNING!
Toxic gases
The vacuum of the WFE 2ES is insufficient for direct extraction.
Toxic gases are created when soldering, which can be harmful to
health if not filtered.
Z Only use the WFE 2ES for surface soldering smoke extraction.
Soldering or welding enamel-covered wires
When soldering or welding enamel-covered wires, use the standard
filter mat F5 and a class F7 fine dust filter.
Extraction of adhesive vapours
When extracting adhesive vapours, use a wide band gas filter
(without HEPA filter).
Extraction during soldering and welding
1. Check filter for suitability and utilisability.
2. Connect extraction hose to vacuum connection (3) of the
WFE 2ES.
3. Position and secure extraction hose.
4. Switch on WFE 2ES and start extraction.
WARNING!
Auto-ignition of the activated carbon
A high concentration of noxious gas can result in considerable
heating of the activated carbon, which can lead to auto-ignition of
the filter.
Z Before switching off, run the unit for several minutes with air
free of noxious gas.
5. When the soldering/adhesion process is complete,
run the unit for 5 minutes free of noxious gas.
6. Shut down unit
WFE 2ES 7-8
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
7 Changing filter
WARNING!
Unfiltered harmful substances and gases
A supersaturated activated carbon filter cannot absorb any more
harmful substances and gases. The gases and harmful
substances are released again unfiltered to the environment.
Z Observe the recommended filter change intervals.
Note Different fluxes, flux concentrations and different dust
concentrations in the extracted air can considerably reduce the
service life of the filter.
The filter must therefore be inspected regularly and replaced if
necessary.
Recommendation for filter change:
Z In single-shift operation, check the pre-filter (=fine dust filter)
every 10 days and replace if badly contaminated.
Z Replace the compact filter after the 6th to 8th pre-filter change.
Removing filter:
1. Disconnect the mains plug (7) from the mains power supply.
2. Open the turnbuckles (4) between the turbine housing (8) and
filter housing (2).
3. Lift up the filter housing (2).
4. Remove the contaminated fine dust filter (10) from the compact
filter (11)
or
remove the contaminated compact filter (11).
Note
Dispose of the contaminated filter as hazardous waste in
accordance with the specifications in the country of use.
Installing new filter:
5. Insert compact filter (11) (observe flow direction).
6. Insert fine dust filter (10) in compact filter (11).
7. Close filter housing (2).
8. Close turnbuckles (4).
9. Note date of filter replacement on maintenance label and affix on
housing in clearly visible position.
10. Insert mains plug (7).
The unit is now ready for operation again.
8-8 WFE 2ES
8 Fault messages and fault elimination
Fault Possible cause Corrective measures
No extraction capability
Pipe system leaking
Filter contaminated
Seal pipe system
Change filte
r
WFE 2ES does not start up
Thermal cut-off Allow the WFE 2ES to cool
down
Switch on again after approx. 3h
HEPA filter contaminated too
quickly
No pre-filter inserted Insert pre-filter
F7 Insert pre-filter
Insert pre-separator (with high
solids content)
9 Accessories
T005 36 571 99 KIT1WF for WFE 2 surface extraction
T005 36 572 99 KIT1WF for WFE 2 surface extraction
T005 87 358 62 Filter housing
T005 87 627 56 Extraction hose, Ø. 60 (5 m)
T005 87 627 01 H12 filter set with 10 F5 prefilters
comprising: H12 HEPA filter, wide band gas filter
(10 % activated charcoal)
T005 87 627 03 Fine dust filter F5 (10 pieces)
T005 87 627 04 Housing upper section
Fine dust filter for Compact filter:
T005 87 359 36 H13 HEPA compact filter +gas filter
T005 87 359 37 Fine dust filter F5 (10 pieces)
T005 87 359 38 Fine dust filter F7 (10 pieces)
10 Disposal
Dispose of replaced equipment parts, filters or old devices in
accordance with the rules and regulations applicable in your country.
11 Warranty
Claims based on defects will fall under the statute of limitations
12 months after delivery to the purchaser of the goods. This shall not
apply to rights of recourse of the purchaser according to sections
478, 479 German Civil Code.
We shall only be liable in the case of a warranty we have issued if
the quality or service life guarantee has been issued by us in writing
with reference to the term "warranty".
Subject to technical alterations and amendments! See the updated
operating instructions at www.weller-tools.com.
EN
FR
IT
ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
WFE 2ES
Mode d'emploi
WFE 2ES
WFE 2ES
Vue d'ensemble de
l'appareil
1 Ouverture d'air d'évacuation
2 Corps de filtres
3 Prise d'aspiration
4 Attaches
5 Interrupteur d'alimentation
6 Fusible
7 Branchement secteur
8 Carter de turbine
9 Bouchon
10 Filtre pour poussières fines
11 Filtre compact
12 Plaque de turbine
10
11
12
8
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163

Weller WFE 2ES Používateľská príručka

Typ
Používateľská príručka

V iných jazykoch