7
Electrical Installation
The panel is equipped with a 1/N 230 V / 50 Hz twin- conductor.
Color marking of the conductors:
Phase – brown,
Central (active) conductor – blue.
The supply cable is connected to the box on the wall, see picture 3. If the supply cord of the appliance is damaged, it has to
be replaced by the manufacturer, their service technician or a similarly qualified person in order to avoid the occurrence of a
dangerous situation.
Panel control
To control the panel, we recommend using an external room thermostat with a switch (for example, Fenix Therm 100).
A room thermostat ensures the air in the room is maintained at a set temperature.
Furthermore, the panel is equipped with a limiting thermostat which ensures that the maximum temperature of the panel doesn’t
exceed 80 °C.
Demounting of the panel
Before loosening the fixation brackets, disconnect the panel from the mains using a two- pole switch. Loosen the mounting
screws using tools and lift the panel vertically upwards in such a way that the brackets are released from the screws. Next,
the supply cable needs to be disconnected from the box on the wall.
Warning
Any intervention within the panel itself must be only carried out by a qualified person. Before starting such work, the panel
must be disconnected from the source of electricity. As the material is fragile, extra care must be taken during transport, han-
dling and mounting.
• The panel must not be transported by holding the rail.
• The maximum load capacity of the rail is 15kg.
CAUTION: Towels, bath towels and similar may only be placed on the metal rail of the panel. The rail is designed only for the drying of textiles
washed in water.
Important safety instructions — CAUTION
Do not cover the panel under any circumstances. The sign “DO
NOT COVER” is a warning that any material by which the panel
is covered may cause damage to the panel. No furniture may be
placed in front of the panel (see picture 5), as the free circula-
tion of air must not be impeded. Remove any dust from the
panel regularly, at least before the start of every heating season.
Do not touch the panel when in the bathtub or shower!
CAUTION: If the glass is damaged, the heater must not be used.
The panel can be mounted on bases of flammability class C1,
C2
• This appliance is not designed to be used by people (including children) whose physical, sensorial or mental disability or lack
of experience and knowledge prevent the safe operation of the appliance, unless they are supervised or have been instructed on
how to use the appliance by a person who is responsible for their safety.
• Children should be supervised in order to ensure that they do not play with the appliance.