Dometic CoolAir RT 780 Návod na inštaláciu

Typ
Návod na inštaláciu
Assembly kit for
Volvo Globetrotter XL (L2H3)
Installation manual . . . . . . . . . . . . . . .9
Montagesatz für
Volvo Globetrotter XL (L2H3)
Einbauanleitung . . . . . . . . . . . . . . . .25
Kit de montage pour
Volvo Globetrotter XL (L2H3)
Notice de montage . . . . . . . . . . . . . .42
Juego de montaje para
Volvo Globetrotter XL (L2H3)
Instrucciones de instalación . . . . . . .60
Set di montaggio per
Volvo Globetrotter XL (L2H3)
Istruzioni di montaggio . . . . . . . . . . .78
Montageset voor
Volvo Globetrotter XL (L2H3)
Montagehandleiding. . . . . . . . . . . . .95
Monteringssæt til
Volvo Globetrotter XL (L2H3)
Installationsvejledning . . . . . . . . . . 112
Monteringssats för
Volvo Globetrotter XL (L2H3)
Monteringsanvisning . . . . . . . . . . .128
Monteringssett for
Volvo Globetrotter XL (L2H3)
Montasjeveiledning . . . . . . . . . . . .144
Asennussarja malleihin
Volvo Globetrotter XL (L2H3)
Asennusohje . . . . . . . . . . . . . . . . .159
Kit de montagem para
Volvo Globetrotter XL (L2H3)
Instruções de montagem . . . . . . . .174
Монтажный комплект для
Volvo Globetrotter XL (L2H3)
Инструкция по монтажу . . . . . . . .190
Zestaw montażowy do
Volvo Globetrotter XL (L2H3)
Instrukcja montażowa . . . . . . . . . .207
EN
DE
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
PL
Montážní sada pro vozidla
Volvo Globetrotter XL (L2H3)
Návod k instalaci . . . . . . . . . . . . . . 224
Montážna súprava pre
Volvo Globetrotter XL (L2H3)
Montážny návod . . . . . . . . . . . . . . 239
Szerelőkészlet a következőkhöz:
Volvo Globetrotter XL (L2H3)
Szerelési útmutató. . . . . . . . . . . . . 256
CS
SK
HU
CoolAir RT780
3
CoolAir RT780
276358
169
1
830
2
CoolAir RT780
4
1
3
4
5
CoolAir RT780
1
2
3
5
4
5
CoolAir RT780
6
1
2
3
4
5
6
7
6
134567
8
9
2
7
7
CoolAir RT780
12
11
10
1
2
3
8
7
4 9
6
5
7
11
M
M
8
CoolAir RT780
8
bl br gl gr ro sw w
DE Blau Braun Gelb Grün Rot Schwarz Weiß
EN Blue Brown Yellow Green Red Black White
FR Bleu Marron Jaune Vert Rouge Noir Blanc
ES Azul Marrón Amarillo Verde Rojo Negro Blanco
IT Blu Marrone Giallo Verde Rosso Nero Bianco
NL Blauw Bruin Geel Groen Rood Zwart Wit
DA Blå Brun Gul Grøn Rød Sort Hvid
SV Blå Brun Gul Grön Röd Svart Vit
NO Blå Brun Gul Grønn Rød Svart Hvit
FI Sininen Ruskea Keltainen Vihr Punainen Musta Valkoinen
PT Azul Castanho Amarelo Verde Cinzento Vermelho Preto
RU Синий Коричневый Желтый Зеленый Красный Черный Белый
PL Niebieski Brązowy Żółty Zielony Czerwony Czarny Biały
CS Modrá Hněda Žlutá Zelená Červená Černá Bílá
SK Modrá Hnedá Žltá Zelená Červená Čierna Biela
HU Kék Barna Sárga Zöld Piros Fekete Fehér
EN
9
CoolAir RT780
Contents
1 Symbols and formats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.1 Using the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Handling electrical cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Conventions in this manual. . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.1 General information on the installation manual . . . . . . . . . . . . . . . . . . . 12
3.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
7.1 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7.2 Removing the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.3 Preparing the unit fastening. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.4 Preparing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.5 Attaching the seal for the cab roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.6 Installing the unit in the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7.7 Installing the electrical supply lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.8 Fastening the cover frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8 Configuration of unit software . . . . . . . . . . . . . . . . . . . . . . . . .19
8.1 Starting and ending configuration mode . . . . . . . . . . . . . . . . . . . . . . . . 20
8.2 Menu level 1: Set temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8.3 Menu level 2: Low voltage cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
8.4 Menu level 3: Operating mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8.5 Menu level 4: Default setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8.6 Menu level 5: Temperature unit display. . . . . . . . . . . . . . . . . . . . . . . . . 23
9 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Symbols and formats CoolAir RT780
10
1 Symbols and formats
!
!
A
I
Action: This symbol indicates that action is required on your part. The
required action is described step-by-step.
This symbol describes the result of an action.
Fig. 1 5, page 3: This refers to an element in an illustration. In this case,
item 5 in figure 1 on page 3.
2 Safety instructions
You must read the entire manual thoroughly and carefully.
We can only guarantee the reliability of the air conditioning roof unit if the
instructions are adhered to. The same applies to the prevention of injury
and damage to property.
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and
excess voltage
Alterations to the product without express permission from the manu-
facturer
Use for purposes other than those described in the operating manual
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal
or serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and
impair the function of the product.
NOTE
Supplementary information for operating the product.
EN
11
CoolAir RT780 Safety instructions
2.1 Using the device
The freedom of movement of semi-trailers (of the outer edges of the
semi-trailer when turning or jackknifing) and other vehicle attachments
must not be restricted.
Only use the air conditioning roof unit for the purpose specified by the
manufacturer and do not make any alterations or structural changes
to the device.
Do not use the air conditioning roof unit if it is visibly damaged.
The air conditioning roof unit must be installed safely so that it cannot
tip over or fall down.
Installation, maintenance and repair work may only be carried out by
qualified personnel from a specialist company who are familiar with
the risks involved and the relevant regulations.
Do not use the air conditioning roof unit near flammable fluids and
gases.
Do not operate the air conditioning roof unit if the ambient temperature
is below 0 °C.
Do not undo the upper cover of the air conditioning roof unit in the
event of a fire. Use approved extinguishing agents instead. Do not use
water to extinguish fires.
Please inquire from your vehicle manufacturer whether the height
entered in your vehicle documentation needs to be altered due to the
installation of the air conditioning roof unit (height 169 mm).
Disconnect all power supply lines when working on the air conditioning
roof unit (cleaning, maintenance, etc).
2.2 Handling electrical cables
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive
materials (metal).
Do not pull on the cables.
Attach and lay the cables in such a manner that they cannot be tripped
over or damaged.
The electrical power supply may only be connected by a specialist
workshop.
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
Never lay power supply lines (battery leads) in the vicinity of signal or
control cables.
Conventions in this manual CoolAir RT780
12
3 Conventions in this manual
3.1 General information on the installation manual
This installation manual contains the essential information and instruc-
tions for installing the air conditioning roof unit. The information contained
is orientated towards the company installing the air conditioning roof unit.
The following instructions are intended to help you properly use the
installation manual:
The installation manual is part of the scope of delivery and should be
stored carefully.
The installation manual provides you with important information on the
installation of the device and can also be used as a reference material
in the event of repairs.
The manufacturer assumes no liability for non-observance of this
installation manual. Any claims are excluded in this case.
3.2 Target group
The installation and configuration information in this manual is intended
for qualified installation personnel who are familiar with the guidelines
and safety precautions to be applied during the installation of lorry
accessory parts.
4 Intended use
The installation kit (item no. 9100300099) enables the installation of an
air conditioning roof unit CoolAir RT780 (item no. 9105306291) in a roof
ventilation opening (hatch) provided at the plant in a
Volvo Globetrotter XL (L2H3) driver cab.
A
I
NOTICE!
The RT780 unit is not suitable for installation in construction
machines, agricultural machines or similar equipment. They will not
work properly if exposed to strong vibrations.
Operating the RT780 unit with voltages other than those specified
can result in damage to the devices.
NOTE
The RT780 unit is only designed for ambient temperatures of up to
43 °C.
EN
13
CoolAir RT780 Scope of delivery
5 Scope of delivery
CoolAir RT780 installation kit for VOLVO Globetrotter XL (L2H3),
item no. 9100300099
6 Accessories
Available as accessories (not included in the scope of delivery):
Part designation Quantity Item no.
Installation manual 1 4445101429
1/4" hexagon bit 1 4445900172
Thread insert with flange M8 8 4445200068
2.5 m insulating tape (profile: 10 x 20 mm) 1
Spacer sleeve L = 18 mm, 14 mm 8 4443900236
Hex screw M8 x 40 8
Spring washer M8 8
Washer 8.4 x 20 8
Connection cable 6 mm² x 4 m 1 4441300149
Cable binder 1
Cover frame 1 4443000289
Self-tapping screw 4.8 x 50 6
Washer M6 6
Part designation Item no.
Connection cable 8 mm² x 9.5 m 9100300027
Installation CoolAir RT780
14
7Installation
A
7.1 Notes on installation
These installation instructions must be read completely prior to the instal-
lation of the air conditioning roof unit.
The following tips and instructions must be observed wile installing the air
conditioning roof unit:
!
Always check whether any vehicle components could be damaged or
their operation impaired by the unit before installing the air condition-
ing roof unit. You can use fig. 1, page 3 and fig. 2, page 3 to check
the dimensions of the installed unit. The dotted line indicates the mid-
dle of the sunroof opening.
Before installation, find out (by consulting the manufacturer of the
vehicle) whether the construction is designed for the static weight and
the loads of the parking cooler when the vehicle is in motion. The
manufacturer of the air conditioning roof unit assumes no liability
whatsoever.
The roof inclination of the mounting surface may not exceed 8° in the
direction of travel.
The supplied assembly parts must not be modified during installation.
The ventilation slots (grill) may not be covered (minimum distance
from other attachment parts: 10 cm).
NOTICE!
The air conditioning roof unit may only be installed by qualified per-
sonnel from a specialist company. The following information is
intended for technicians who are familiar with the guidelines and
safety precautions to be applied.
The manufacturer only assumes liability for parts included in the
scope of delivery. The validity of the warranty expires if the device is
installed together with third-party parts.
Check whether the roof of the vehicle is able to support the weight of
a person before climbing onto it. Ask the vehicle manufacturer about
the permitted roof loads.
WARNING!
Make sure that all electrical components are electrically discharged
before carrying out work on them!
EN
15
CoolAir RT780 Installation
You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. On
some vehicles, larger consumers connected to the terminal block are
switched off after a short while if the power requirement is too high.
Ask your vehicle manufacturer for the specifications of the terminal
block.
When installing the system and making the electrical connections,
observe the guidelines from the body manufacturer.
Pay attention to the connection plan for the device:
!
!
I
No. in fig. 8,
page 7
Designation
1 Control pad
2 Connection cable
3 Room temperature sensor
4Earth
5 Klickson (compressor)
6 Compressor
7 Condenser fan
8 Vaporiser fan
9Earth
10 25 A fuse
11 2 A fuse
12 4 A fuse
WARNING!
Before installing the air conditioning roof unit, all connections to the
battery of the vehicle must be disconnected.
Non-observance of this regulation can result in danger of electrocution.
CAUTION!
Improper installation of the air conditioning roof unit can result in irrepa-
rable damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning
roof unit is not installed according to this installation manual. That
applies to malfunctions and the safety of the air conditioning roof unit, in
particular to injuries and damage to property.
NOTE
After installing the unit, the specified parameters of the unit software
must be checked (chapter “Configuration of unit software” on page 19).
Installation CoolAir RT780
16
7.2 Removing the sunroof
Remove all screws and fixtures of the existing sunroof.
Take out the sunroof.
Remove the sealant around the opening, so that the surface is clean
and free of grease.
I
7.3 Preparing the unit fastening
Enlarge the existing 6.5 mm drill holes for fastening the sunroof to
a diameter of 8.5 mm (fig. 5 5, page 5).
7.4 Preparing the unit
A
Place the air conditioning roof unit on a work surface with the housing
facing down.
A
Screw in the 8 self-threading M8 thread inserts in the blind holes
marked with “1” (fig. 3 1, page 4).
Use the supplied 1/4" bit for this.
NOTE
Dispose of all waste material, glue, silicone and seals separately.
Observe the local disposal guidelines.
NOTICE!
During preparatory work on the surfaces, secure the unit from falling
down.
Make sure that the work surface is clean and level to ensure that the unit
is not damaged.
NOTICE!
Screw in the thread insert vertically.
Do not exceed the screw torque of 10 Nm.
EN
17
CoolAir RT780 Installation
7.5 Attaching the seal for the cab roof
A
Stick the 2.5 m insulating tape (10 x 20 mm) to the cab roof, following
the outline of the sunroof opening (fig. 4, page 4).
Provide the abutting edge and the top edge of the insulating tape with
an unhardened plastic butyl sealing compound (e.g.
SikaLastomer-710).
7.6 Installing the unit in the sunroof
Set the unit down centrally aligned and in the direction of travel
(fig. 1, page 3) on the sunroof opening.
I
Place the spacer sleeve L = 18 mm (fig. 5 1, page 5) on the
fastening drill holes as shown in fig. 5, page 5.
Screw one hex screw M8 x 40 mm (fig. 5 4, page 5) with a washer
(fig. 5 2, page 5) and spring washer (fig. 5 3, page 5) in the
8 thread inserts on the bottom of the unit.
A
Tighten the screws with a torque of 8 Nm.
NOTICE!
Ensure that the adhesive surface for the seal between the unit and the
cab roof is clean (free of dust, oil, etc.).
NOTE
Make sure the air conditioning roof unit is centred perfectly. The seal
must be applied continuously around the air conditioning roof unit after
being placed on the roof of the vehicle. This is the only way to ensure a
tight seal.
NOTICE!
Do not exceed the specified torque under any circumstances. This is the
only way to ensure that the thread inserts are not torn out.
Installation CoolAir RT780
18
7.7 Installing the electrical supply lines
!
A
I
You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. Ask your
vehicle manufacturer for the specifications of the terminal block.
Lay the supply line and connect it to the vehicle (red line to plus, black
line to minus).
Plug in the supply line plug into the socket of the air conditioning roof
unit supply line.
To relieve strain on the supply line, secure it with a cable tie, e.g. to
the cab roof.
7.8 Fastening the cover frame
A
fig. 6, page 6
Fasten the cover frame (5) to the cab roof (original fastening points)
with the six self-tapping screws (7) and washers (6).
WARNING!
The electrical power supply may only be performed by qualified
personnel with specialist knowledge.
Make sure there is no voltage present on electrically operated
components before carrying out work on them!
NOTICE!
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
The battery must be able to supply the required current and voltage
(chapter “Technical data” on page 24).
NOTE
The unit is equipped as standard with a 4 m long cable with a cross-
section of 6 mm
2
. If longer cable lengths are required, then the cable
cross-section must be increased by an authorised specialist workshop:
In this case cut off the cable as closely as possible to the unit
(max. 0.5 m) and then establish a suitable connection with a larger
cable cross-section.
When the cable is extended by 4 m to 6 m in length, the manufacturer
recommends using a cross-section of at least 8 mm
2
.
NOTICE!
Screw the screws in carefully order not to damage the cover frame.
EN
19
CoolAir RT780 Configuration of unit software
8 Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set
at the control panel (fig. 7, page 6).
I
Menu
level
Parameter Meaning
Default
setting
1 Set temperature The unit starts at the temperature
defined here.
20 °C (68 °F)
2 Low voltage
cut-off
The battery monitor shuts down the unit
at the voltage defined here.
Characteristic
figure 4 =
22,8 V
3 Operating mode The unit starts with the operating mode
defined here.
0 = Automatic
mode
4 Default settings Parameters 1 – 3 can be reset to the
default settings.
--
5 Temperature unit
display
The temperature can be displayed in °C
or °F.
°C
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is
available.
Configuration of unit software CoolAir RT780
20
8.1 Starting and ending configuration mode
The adjustable parameters can be changed in configuration mode:
When using the button to switch on the unit, hold both buttons +
and
pressed until the compressor LED flashes.
You are now in configuration mode.
The display version (e. g. “3.1S”) appears in the display for 2 seconds.
The first digit of the display shows the menu level and the second and
third digits show the parameters which can be set, e.g. 1.17 for menu
level 1 and a set target value of 17 °C.
I
Press the button to quit configuration mode.
8.2 Menu level 1: Set temperature
The unit always starts with a defined value for the room temperature. This
parameter can be configured between 17 and 30 °C (62 and 86 °F).
Start configuration mode (chapter “Starting and ending configuration
mode” on page 20).
The first digit of the display shows the menu level and the second and
third show the parameter which can be set.
Press the button to change the parameters.
Use the +
and
buttons
to select the target value (in °C) at which the
unit should start operation.
The digits in the display flash until the parameter you entered is
confirmed.
Press the button to confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 1 again and can use the +
and
buttons to
switch between menu levels.
NOTE
If you make no entry on the control panel for 60 seconds, the unit quits
configuration mode and shuts down.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272

Dometic CoolAir RT 780 Návod na inštaláciu

Typ
Návod na inštaláciu