RT780 MAN TGX XXL

Dometic RT780 MAN TGX XXL, CoolAir RT780 Návod na inštaláciu

  • Prečítal som si inštalačnú príručku pre klimatizačnú jednotku Dometic CoolAir RT780. Som pripravený zodpovedať vaše otázky týkajúce sa montáže, zapojenia, nastavenia a prevádzky tejto jednotky, ktorá je určená pre nákladné vozidlá MAN TGX XXL. Príručka obsahuje podrobné informácie o jednotlivých krokoch inštalácie, ako aj o konfigurácii parametrov, ako je teplota chladenia a ochrana proti podnapätiu.
  • Ako nastaviť požadovanú teplotu?
    Ako funguje ochrana proti podnapätiu?
    Aké sú rozmery jednotky?
AIR CONDITIONERS
COOLAIR
RT780
Assembly kit for MAN TGX XXL
Installation Manual . . . . . . . . . . . . . . . . . . 8
Montagesatz für MAN TGX XXL
Montageanleitung . . . . . . . . . . . . . . . . . 24
Kit de montage pour MAN TGX XXL
Instructions de montage. . . . . . . . . . . . . .41
Juego de montaje para MAN TGX XXL
Instrucciones de montaje . . . . . . . . . . . . 58
Kit de montagem para MAN TGX XXL
Instruções de montagem . . . . . . . . . . . . 76
Set di montaggio per MAN TGX XXL
Indicazioni di montaggio . . . . . . . . . . . . 94
Montageset voor MAN TGX XXL
Montagehandleiding . . . . . . . . . . . . . . .112
Monteringssæt til MAN TGX XXL
Monteringsvejledning . . . . . . . . . . . . . 129
Monteringssats för MAN TGX XXL
Monteringsanvisning . . . . . . . . . . . . . . 145
Monteringssett for MAN TGX XXL
Monteringsanvisning . . . . . . . . . . . . . . .161
Asennussarja malleihin MAN TGX XXL
Asennusohje . . . . . . . . . . . . . . . . . . . . . 177
Монтажный комплект для
MAN TGX XXL
Инструкция по монтажу. . . . . . . . . . . . 193
Zestaw montażowy do MAN TGX XXL
Instrukcja montażu . . . . . . . . . . . . . . . . . 211
Montážna súprava pre MAN TGX XXL
Návod na montáž . . . . . . . . . . . . . . . . . 228
Montážní sada pro vozidla MAN TGX XXL
Návod k montáži. . . . . . . . . . . . . . . . . . 244
Szerelőkészlet a következőkhöz:
MAN TGX XXL
Szerelési útmutató . . . . . . . . . . . . . . . . 260
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
RT780-MAN--I-16s.book Seite 1 Donnerstag, 14. Juni 2018 7:49 19
RT780-MAN--I-16s.book Seite 2 Donnerstag, 14. Juni 2018 7:49 19
3
CoolAir RT780
276358
188
1
830
2
RT780-MAN--I-16s.book Seite 3 Donnerstag, 14. Juni 2018 7:49 19
CoolAir RT780
4
1
2
2
2
3
4
RT780-MAN--I-16s.book Seite 4 Donnerstag, 14. Juni 2018 7:49 19
5
CoolAir RT780
1
3
5
4
2
6
5
1
2
3
4
5
8
7
6
9
10
6
RT780-MAN--I-16s.book Seite 5 Donnerstag, 14. Juni 2018 7:49 19
CoolAir RT780
6
134567
8
9
2
7
12
11
10
1
2
3
8
7
4 9
6
5
7
11
+24 V –/0 V
M
M
M
8
RT780-MAN--I-16s.book Seite 6 Donnerstag, 14. Juni 2018 7:49 19
7
CoolAir RT780
bl br gl gr ro sw w
EN Blue Brown Yellow Green Red Black White
DE Blau Braun Gelb Grün Rot Schwarz Weiß
FR Bleu Marron Jaune Vert Rouge Noir Blanc
ES Azul Marrón Amarillo Verde Rojo Negro Blanco
PT Azul Castanho Amarelo Verde Cinzento Vermelho Preto
IT Blu Marrone Giallo Verde Rosso Nero Bianco
NL Blauw Bruin Geel Groen Rood Zwart Wit
DA Blå Brun Gul Grøn Rød Sort Hvid
SV Blå Brun Gul Grön Röd Svart Vit
NO Blå Brun Gul Grønn Rød Svart Hvit
FI Sininen Ruskea Keltainen Vihr Punainen Musta Valkoinen
RU Синий Коричневый Желтый Зеленый Красный Черный Белый
PL Niebieski Brązowy Żółty Zielony Czerwony Czarny Biały
SK Modrá Hnedá Žltá Zelená Červená Čierna Biela
CS Modrá Hněda Žlutá Zelená Červená Černá Bílá
HU Kék Barna Sárga Zöld Piros Fekete Fehér
RT780-MAN--I-16s.book Seite 7 Donnerstag, 14. Juni 2018 7:49 19
EN
CoolAir RT780
8
Contents
1 Symbols and formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 Using the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.2 Handling electrical cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3 Conventions in this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 General information on the installation manual . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.1 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6.2 Removing the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
6.3 Preparing the unit fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
6.4 Preparing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
6.5 Attaching the seal for the cab roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6.6 Installing the unit in the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6.7 Installing the electrical supply lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
6.8 Fastening the cover frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
7 Configuration of unit software . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.1 Starting and ending configuration mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
7.2 Menu level 1: Set temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
7.3 Menu level 2: Low voltage cut-off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.4 Menu level 3: Operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
7.5 Menu level 4: Default setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.6 Menu level 5: Temperature unit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
RT780-MAN--I-16s.book Seite 8 Donnerstag, 14. Juni 2018 7:49 19
9
EN
CoolAir RT780 Symbols and formats
1 Symbols and formats
!
!
A
I
2 Safety instructions
You must read the entire manual thoroughly and carefully.
We can only guarantee the reliability of the air conditioning roof unit if the
instructions are adhered to. The same applies to the prevention of injury and
damage to property.
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and incorrect
connection voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the
function of the product.
NOTE
Supplementary information for operating the product.
RT780-MAN--I-16s.book Seite 9 Donnerstag, 14. Juni 2018 7:49 19
EN
Safety instructions CoolAir RT780
10
2.1 Using the device
The freedom of movement of semi-trailers (of the outer edges of the semi-
trailer when turning or jackknifing) and other vehicle attachments must not be
restricted.
Only use the air conditioning roof unit for the purpose specified by the
manufacturer and do not make any alterations or structural changes to the
device.
Do not use the air conditioning roof unit if it is visibly damaged.
The air conditioning roof unit must be installed safely so that it cannot tip over
or fall down.
Installation, maintenance and repair work may only be carried out by
qualified personnel from a specialist company who are familiar with the risks
involved and the relevant regulations.
Do not use the air conditioning roof unit near flammable fluids and gases.
Do not operate the air conditioning roof unit if the ambient temperature is
below 0 °C.
Do not undo the upper cover of the air conditioning roof unit in the event of
a fire. Use approved extinguishing agents instead. Do not use water to extin-
guish fires.
Please inquire from your vehicle manufacturer whether the height entered in
your vehicle documentation needs to be altered due to the installation of the
air conditioning roof unit (height 188 mm).
Disconnect all power supply lines when working on the air conditioning roof
unit (cleaning, maintenance, etc).
2.2 Handling electrical cables
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive materials
(metal).
Do not pull on the cables.
Attach and lay the cables in such a manner that they cannot be tripped over
or damaged.
The electrical power supply may only be connected by a specialist work-
shop.
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
Never lay power supply lines (battery leads) in the vicinity of signal or control
cables.
RT780-MAN--I-16s.book Seite 10 Donnerstag, 14. Juni 2018 7:49 19
11
EN
CoolAir RT780 Conventions in this manual
3 Conventions in this manual
3.1 General information on the installation manual
This installation manual contains the essential information and instructions for
installing the air conditioning roof unit. The information contained is orientated
towards the company installing the air conditioning roof unit.
The following instructions are intended to help you properly use the installation
manual:
The installation manual is part of the scope of delivery and should be stored
carefully.
The installation manual provides you with important information on the
installation of the device and can also be used as a reference material in the
event of repairs.
The manufacturer assumes no liability for non-observance of this installation
manual. Any claims are excluded in this case.
3.2 Target group
The installation and configuration information in this manual is intended for
qualified installation personnel who are familiar with the guidelines and safety
precautions to be applied during the installation of lorry accessory parts.
4 Intended use
The installation kit enables the installation of an air conditioning roof unit
CoolAir RT780 (ref. no. 9105306291) in a roof ventilation opening (hatch)
provided at the plant in a MAN TGX XXL driver cab.
A
I
NOTICE!
The RT780 unit is not suitable for installation in construction machines,
agricultural machines or similar equipment. They will not work properly if
exposed to strong vibrations.
Operating the RT780 unit with voltages other than those specified can
result in damage to the devices.
NOTE
The RT780 unit is only designed for ambient temperatures of up to 43 °C.
RT780-MAN--I-16s.book Seite 11 Donnerstag, 14. Juni 2018 7:49 19
EN
Scope of delivery CoolAir RT780
12
5 Scope of delivery
CoolAir RT780 installation kit for MAN TGX XXL
Part designation Quantity Ref. no.
Installation manual 1 4445102400
1/4" hexagon bit 1 4445900172
Thread insert with flange M8 8 4445200068
Thread insert with flange M6 4 4445200069
2.5 m insulating tape (profile: 35 x 20 mm) 1
Spacer sleeve L = 40 mm, 14 mm 8 4443900237
Hex screw M8 x 60 8
Spring washer M8 8
Washer 8.4 x 20 8
MAN underlay strip 4 4442500511
Connection cable 8 mm² x 11 m 1 4441300243
Cable binder 1
Cover frame
Grey
Beige
1
4443000296
4443000483
Allen screw with cylindrical head M6 x 100 4
Washer M6 4
Spacer sleeve L = 48 mm, 10 mm 4 4443900241
Spacer sleeve L = 40 mm, 10 mm 4 4443900240
Maxi Fuse holder 1 4441600172
Maxi Fuse 30 A 1 4441550009
Ring terminal M8 1
Ring terminal M10 1
Joint connector 1
RT780-MAN--I-16s.book Seite 12 Donnerstag, 14. Juni 2018 7:49 19
13
EN
CoolAir RT780 Installation
6 Installation
A
6.1 Notes on installation
These installation instructions must be read completely prior to the installation of
the air conditioning roof unit.
The following tips and instructions must be observed wile installing the air con-
ditioning roof unit:
!
Always check whether any vehicle components could be damaged or their
operation impaired by the unit before installing the air conditioning roof unit.
You can use fig. 1, page 3 and fig. 2, page 3 to check the dimensions of
the installed unit. The dotted line indicates the middle of the sunroof open-
ing.
Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of
the parking cooler when the vehicle is in motion. The manufacturer of the air
conditioning roof unit assumes no liability whatsoever.
The roof inclination of the mounting surface may not exceed 8° in the
direction of travel.
The supplied assembly parts must not be modified during installation.
The ventilation slots (grill) may not be covered (minimum distance from other
attachment parts: 10 cm).
The unit must be connected directly to the battery.
For installation and repair work, adhere to the corresponding rules of
technology and the MAN installation guidelines.
NOTICE!
The air conditioning roof unit may only be installed by qualified personnel
from a specialist company. The following information is intended for
technicians who are familiar with the guidelines and safety precautions to
be applied.
The manufacturer only assumes liability for parts included in the scope of
delivery. The validity of the warranty expires if the device is installed
together with third-party parts.
Check whether the roof of the vehicle is able to support the weight of a
person before climbing onto it. Ask the vehicle manufacturer about the
permitted roof loads.
WARNING!
Make sure that all electrical components are electrically discharged before
carrying out work on them!
RT780-MAN--I-16s.book Seite 13 Donnerstag, 14. Juni 2018 7:49 19
EN
Installation CoolAir RT780
14
When installing the system and making the electrical connections, observe
the guidelines from the body manufacturer.
Pay attention to the connection plan for the device:
!
!
I
No. in
fig. 8, page 6
Designation
1Control pad
2 Connection cable
3 Room temperature sensor
4Earth
5 Klickson (compressor)
6Compressor
7Condenser fan
8Vaporiser fan
9Earth
10 25 A fuse
11 2 A fuse
12 4 A fuse
WARNING!
Before installing the air conditioning roof unit, all connections to the battery of
the vehicle must be disconnected.
Non-observance of this regulation can result in danger of electrocution.
CAUTION!
Improper installation of the air conditioning roof unit can result in irreparable
damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning roof
unit is not installed according to this installation manual. That applies to mal-
functions and the safety of the air conditioning roof unit, in particular to injuries
and damage to property.
NOTE
After installing the unit, the specified parameters of the unit software must be
checked (chapter “Configuration of unit software” on page 18).
RT780-MAN--I-16s.book Seite 14 Donnerstag, 14. Juni 2018 7:49 19
15
EN
CoolAir RT780 Installation
6.2 Removing the sunroof
Remove all screws and fixtures of the existing sunroof.
Take out the sunroof.
Remove the sealant around the opening, so that the surface is clean and free
of grease.
I
6.3 Preparing the unit fastening
Enlarge the existing 6.5 mm drill holes for fastening the sunroof to a
diameter of 8.5 mm (fig. 5 5, page 5).
6.4 Preparing the unit
A
Place the air conditioning roof unit on a work surface with the housing facing
down.
A
Screw in the 8 self-threading M8 thread inserts in the blind holes marked with
“1” (fig. 3 1, page 4).
Use the supplied 1/4" bit for this.
Screw in the 4 self-threading M6 thread inserts in the corresponding blind
holes on the left and right of the outlet unit as shown in fig. 3 2, page 4.
Use a 5 mm hexagon bit for this.
NOTE
Dispose of all waste material, glue, silicone and seals separately. Observe the
local disposal guidelines.
NOTICE!
During preparatory work on the surfaces, secure the unit from falling down.
Make sure that the work surface is clean and level to ensure that the unit is not
damaged.
NOTICE!
Screw in the thread insert vertically.
Do not exceed the screw torque of
8 Nm for M6
10 Nm for M8
RT780-MAN--I-16s.book Seite 15 Donnerstag, 14. Juni 2018 7:49 19
EN
Installation CoolAir RT780
16
6.5 Attaching the seal for the cab roof
A
Stick the 2.5 m insulating tape (35 x 20 mm) to the cab roof, following the
outline of the sunroof opening (fig. 4, page 4).
Provide the abutting edge and the top edge of the insulating tape with an
unhardened plastic butyl sealing compound (e.g. SikaLastomer-710).
6.6 Installing the unit in the sunroof
Set the unit down centrally aligned and in the direction of travel (fig. 1,
page 3) on the sunroof opening.
I
Place the spacer sleeve L = 40 mm, 14 mm (fig. 5 1, page 5) on the
fastening drill holes as shown in fig. 5, page 5.
Use the underlay strips supplied (fig. 5 2, page 5) for fastening the unit.
Screw one hex screw M8 x 60 mm (fig. 5 5, page 5) with a washer
(fig. 5 3, page 5) and spring washer (fig. 5 4, page 5) in the 8 thread
inserts on the bottom of the unit.
A
Tighten the screws with a torque of 8 Nm.
NOTICE!
Ensure that the adhesive surface for the seal between the unit and the cab roof
is clean (free of dust, oil, etc.).
NOTE
Make sure the air conditioning roof unit is centred perfectly. The seal must be
applied continuously around the air conditioning roof unit after being placed
on the roof of the vehicle. This is the only way to ensure a tight seal.
NOTICE!
Do not exceed the specified torque under any circumstances. This is the only
way to ensure that the thread inserts are not torn out.
RT780-MAN--I-16s.book Seite 16 Donnerstag, 14. Juni 2018 7:49 19
17
EN
CoolAir RT780 Installation
6.7 Installing the electrical supply lines
!
A
I
Plug the cable strand for the power supply into the unit and run it through the
overhead cupboard on the right to the A pillar.
Run the cable strand down to the central electrics (preferably along the roof
hatch drain hose) and the mounting interface to the outside.
Lay the positive and negative cables for the battery box in a protected place.
Trim the negative cable (black) to length if necessary and attach an
appropriate ring terminal.
Connect the negative cable (black) directly to the negative terminal of the
battery.
I
Attach the fuse holder in a suitable location.
Lay the positive cable (red) to the fuse holder and trim.
Trim the shorter connection cable from the fuse holder to the correct length
and connect with a joint connector on the positive cable (red).
Insulate the connection cable with the joint connectors properly.
Trim the longer connection cable from the fuse holder if necessary and fit a
suitable ring terminal.
Connect the longer connection cable from the fuse holder with the ring
terminal directly to the positive terminal of the battery.
WARNING!
The electrical power supply may only be performed by qualified personnel
with specialist knowledge.
Make sure there is no voltage present on electrically operated components
before carrying out work on them!
NOTICE!
Fit a fuse of 30 amps to the connection to the vehicle's power supply.
The battery must be able to supply the required current and voltage
(chapter “Technical data” on page 23).
NOTE
The unit is equipped as standard with an 11 m long cable with a cross-
section of 8 mm².
The connection must be made directly to the battery.
NOTE
Place the fuse holder no more than 0.3 m from the positive terminal of the
battery.
RT780-MAN--I-16s.book Seite 17 Donnerstag, 14. Juni 2018 7:49 19
EN
Configuration of unit software CoolAir RT780
18
6.8 Fastening the cover frame
A
fig. 6, page 5
Fasten the cover frame (8) to the unit with the four cylindrical screws (10),
washers (9) and the eight spacer sleeves (L = 40 mm, 10 mm: 6;
L=48mm, 10 mm: 7). The spacer sleeves keep the cover frame apart from
the unit.
7 Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set at the
control panel (fig. 7, page 6):
I
NOTICE!
Screw the screws in carefully order not to damage the cover frame.
Menu
level
Parameter Meaning
Default
setting
1 Set temperature The unit starts at the temperature
defined here.
20 °C (68 °F)
2Low voltage
cut-off
The battery monitor shuts down the unit
at the voltage defined here.
Characteristic
figure 4 =
22,8 V
3 Operating mode The unit starts with the operating mode
defined here.
0 = Auto-
matic mode
4 Default settings Parameters 1 – 3 can be reset to the
default settings.
--
5Temperature unit
display
The temperature can be displayed in °C
or °F.
°C
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is available.
RT780-MAN--I-16s.book Seite 18 Donnerstag, 14. Juni 2018 7:49 19
19
EN
CoolAir RT780 Configuration of unit software
7.1 Starting and ending configuration mode
The adjustable parameters can be changed in configuration mode:
When using the button to switch on the unit, hold both buttons +
and
pressed until the compressor LED flashes.
You are now in configuration mode.
The display version (e. g. “3.1S”) appears in the display for 2 seconds.
The first digit of the display shows the menu level and the second and third
digits show the parameters which can be set, e.g. 1.17 for menu level 1 and a
set target value of 17 °C.
I
Press the button to quit configuration mode.
7.2 Menu level 1: Set temperature
The unit always starts with a defined value for the room temperature. This
parameter can be configured between 17 and 30 °C (62 and 86 °F).
Start configuration mode (chapter “Starting and ending configuration mode”
on page 19).
The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
Press the button to change the parameters.
Use the +
and
buttons
to select the target value (in °C) at which the unit
should start operation.
The digits in the display flash until the parameter you entered is confirmed.
Press the button to confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 1 again and can use the +
and
buttons to switch
between menu levels.
NOTE
If you make no entry on the control panel for 60 seconds, the unit quits
configuration mode and shuts down.
RT780-MAN--I-16s.book Seite 19 Donnerstag, 14. Juni 2018 7:49 19
EN
Configuration of unit software CoolAir RT780
20
7.3 Menu level 2: Low voltage cut-off
The battery monitor protects the battery from excessive discharging.
A
If only the set power supply is available here for the air conditioning roof unit, the
unit is switched off.
Start configuration mode (chapter “Starting and ending configuration mode”
on page 19).
The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
Press the
+
button
once to switch to menu level
2
.
Press the button to change the parameter.
The digits in the display flash until the parameter you entered is confirmed.
Use the +
and
buttons
to set the value for low voltage shutdown. The
characteristic figures at second and third place on the display represent the
voltage (V) at which the unit is shut down:
Press the button to confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 2 again and can use the +
and
buttons to switch
between menu levels.
NOTICE!
When the battery monitor switches the device off, the battery only has part of
its charging capacity. Avoid starting repeatedly or operating electrical consum-
ers. Make sure that the battery is recharged. As soon as the required voltage is
available again, the unit can be operated again.
Characteristic
figure
Low voltage
shutdown
Characteristic
figure
Low voltage
shutdown
1 22.2 6 23.0
2 22.4 7 23.1
3 22.6 8 23.2
4 22.8 9 23.4
5 22.9 10 23.6