Fitting the inverter SinePower
16
6 Fitting the inverter
6.1 Mounting instructions
When selecting the installation location, observe the following instructions:
• The inverter can be mounted horizontally or vertically.
• The inverter must be installed in a place that is protected from moisture.
• The inverter may not be installed in the presence of flammable materials.
• The inverter may not be installed in a dusty environment.
• The place of installation must be well ventilated. A ventilation system must be
available for installations in small, enclosed spaces. The minimum clearance
around the inverter must be at least 5 cm (fig. 3, page 4).
• The air intake on the underside or the air outlet on the back of the inverter must
remain clear.
• For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the inverter‘s maximal output load is reduced.
Thereby the inverter may shut down due to overload.
• The device must be installed on a level and sufficiently sturdy surface.
A
6.2 Mounting the inverter
➤ Mount the inverter as shown (fig. 4, page 4).
7 Connecting the inverter
!
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
WARNING!
Never connect more than one consumer device to the inverter. The
connection of more than one device must be executed by an electrically
qualified person complying with the local requirements for protection
against electric shock.
DSP200-400--IO-16s.book Seite 16 Donnerstag, 30. November 2017 8:37 08