Dometic CoolAir RT780, SP950T Návod na inštaláciu

Typ
Návod na inštaláciu
1
4 m
100
100
830
276358
169
100
12
11
10
1
2
3
8
7
4 9
6
5
7
11
M
M
q
w
e
r
y
j
h
g
f
sd
u
i
o
a
t
k l
1(
2)
RT780
Renault Day, Day/Night
1
2
4
3
5
6
RT780-SP950T-Renault-H1--I-16s.book Seite 1 Donnerstag, 14. Juni 2018 10:02 22
2
24 V
10
20
10
7.5
7.5
10
10
10
20
15
20
2
0
20
15
2
0
10
10
20
1
0
10
2
0
10
2
0
1
0
15
7.5
15
15
7.5
2
0
1
0
1010
2
0
5
5
10
7.5
7.5
2
0
10
2.
1.
l
1(
l
1
1
4
3
3
3
8 Nm
y
u
t
w
M8 x 40
M8
14 x 18
8,5 x 20
A B
k
3
33
3 3
5 54 4
3
3
3
33
3 3
44
5 5
2
2
2
2
2
2
1
1
1
1
1
1
1
1
10 Nm
2)
q
r
B
A
e
M4 x 12
M4
M4
s
d
a
h
j
3
33
3 3
5 54 4
3
3
33
33
4 4
5 5
2
2
2
2
2
2
1
1
1
1
1
1
i
10 x 48
o
10 x 39
M6
M6 x 100
f
g
a
7 b
8
c
9
a
0
4445102179 RT L 07/2019
RT780-SP950T-Renault-H1--I-16s.book Seite 2 Donnerstag, 14. Juni 2018 10:02 22
YOUR LOCAL DEALER
dometic.com/dealer
A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of:
DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden
YOUR LOCAL SUPPORT
dometic.com/contact
YOUR LOCAL SALES OFFICE
dometic.com/sales-offices
1
291286
60 100
100
100
779
q
w
e
r
y
j
h
g
f
sd
u
i
o
a
t
k l
1(
4 m
+ 24 V -/ 0 V
ro sw
sw
sw
br
gr
w
br
gr
gl
gr br w
gr/gl
w br w br grbr
M
M
1
2
3
4
5
6
7
8
9
10
11
gr/gl
12
w
gr
sw
br
wbr
grgl
br gr/gl gr
SP950T
Renault Day, Day/Night
1
2
4
3
5
6
RT780-SP950T-Renault-H1--I-16s.book Seite 1 Donnerstag, 14. Juni 2018 10:02 22
2
A B
k
r e
M4 x 12
M4
M4
s
d
a
h
j
3
33
3 3
5 54 4
3
3
33
33
44
5 5
2
2
2
2
2
1
1
1
1
1
1
i
10 x 48
o
10 x 39
M6
M6 x 100
f
g
a
1
1
4
3
3
3
2
8 Nm
y
u
t
q
w
M8 x 45
M8
14 x 18
8,5 x 20
M8
4,2 m
1
2
3
4
24 V
10
20
10
7.5
7.5
10
10
10
20
15
20
2
0
20
15
2
0
10
10
20
1
0
10
2
0
10
2
0
1
0
15
7.5
15
15
7.5
20
1
0
1010
20
5
5
10
7.5
7.5
20
10
1
2.
1.
l
;
l
9
7 b
c
0
a
d
8
4445102179 SP L 07/2019
RT780-SP950T-Renault-H1--I-16s.book Seite 2 Donnerstag, 14. Juni 2018 10:02 22
YOUR LOCAL DEALER
dometic.com/dealer
A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of:
DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden
YOUR LOCAL SUPPORT
dometic.com/contact
YOUR LOCAL SALES OFFICE
dometic.com/sales-offices
AIR CONDITIONERS
COOLAIR
RT780, SP950T
Assembly kit for Renault Trucks Day and
Day & Night driver cab
Installation Manual . . . . . . . . . . . . . . . . . . 3
Montagesatz für Renault Trucks Day und
Day & Night Fahrerhaus
Montageanleitung . . . . . . . . . . . . . . . . . .21
Kit de montage pour Renault Trucks
cabine Day et Day & Night
Instructions de montage. . . . . . . . . . . . . 40
Juego de montaje para Renault Trucks
con cabina Day y Day & Night
Instrucciones de montaje . . . . . . . . . . . . 58
Kit de montagem para Renault Trucks
cabina Day e Day & Night
Instruções de montagem . . . . . . . . . . . . 76
Set di montaggio per cabina di guida per
Renault Tracks Day e Day & Night
Indicazioni di montaggio . . . . . . . . . . . . 94
Montageset voor Renault Trucks Day en
Day & Night bestuurderscabine
Montagehandleiding . . . . . . . . . . . . . . .112
Monteringssæt til Renault-lastbiler med
Day og Day & Night-førerhus
Monteringsvejledning . . . . . . . . . . . . . 130
Monteringssats för Renault Trucks Day-
och Day & Night-hytt
Monteringsanvisning . . . . . . . . . . . . . . 147
Monteringssett for Renault Trucks Day
og Day & Night førerhus
Monteringsanvisning . . . . . . . . . . . . . . .164
Asennussarja Renault-kuorma-autot Day
ja Day & Night -ohjaamolla
Asennusohje . . . . . . . . . . . . . . . . . . . . . . 181
Монтажный комплект для Renault
Trucks с кабиной Day и Day & Night
Инструкция по монтажу . . . . . . . . . . . . 198
Zestaw montażowy do Samochody
ciężarowe Renault z kabiną kierowcy
Day i Day & Night
Instrukcja montażu . . . . . . . . . . . . . . . . . 217
Montážna súprava pre Renault Trucks
Day a Day & Night kabína vodiča
Návod na montáž . . . . . . . . . . . . . . . . . 236
Montážní sada pro vozidla tahač Renault
s kabinou Day a Day & Night
Návod k montáži. . . . . . . . . . . . . . . . . . 253
Szerelőkészlet a következőkhöz: Renault
Trucks Day és Day & Night vezetőfülke
Szerelési útmutató . . . . . . . . . . . . . . . . .270
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
3
EN
CoolAir RT780, SP950T
Please read this instruction manual carefully before installation and
first use, and store it in a safe place. If you pass on the product to
another person, hand over this instruction manual along with it.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Using the device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Handling electrical cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 RT780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 SP950 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.1 RT780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2 SP950 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.1 Notes on installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.2 Removing the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
7.3 Attaching the seal for the cab roof. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7.4 Preparing the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7.5 Installing the unit in the sunroof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7.6 Installing the electrical supply lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.7 Installing supply lines to the condenser unit (SP950T only). . . . . . . . . . . . . . . . 14
7.8 Preparing the cover frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7.9 Fastening the cover frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8 Configuration of unit software . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.1 Starting and ending configuration mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.2 Menu level 1: Set temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8.3 Menu level 2: Low voltage cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8.4 Menu level 3: Operating mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8.5 Menu level 4: Default setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8.6 Menu level 5: Temperature unit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Explanation of symbols CoolAir RT780, SP950T
4
1 Explanation of symbols
!
!
A
I
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and incorrect
connection voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the
function of the product.
NOTE
Supplementary information for operating the product.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
5
EN
CoolAir RT780, SP950T Safety instructions
2.1 Using the device
The freedom of movement of semi-trailers (of the outer edges of the semi-
trailer when turning or jackknifing) and other vehicle attachments must not be
restricted.
Only use the air conditioning roof unit for the purpose specified by the
manufacturer and do not make any alterations or structural changes to the
device.
Do not use the air conditioning roof unit if it is visibly damaged.
The air conditioning roof unit must be installed safely so that it cannot tip over
or fall down.
Installation, maintenance and repair work may only be carried out by
qualified personnel from a specialist company who are familiar with the risks
involved and the relevant regulations.
Do not use the air conditioning roof unit near flammable fluids and gases.
Do not operate the air conditioning roof unit if the ambient temperature is
below 0 °C.
•Do not undo the upper cover of the air conditioning roof unit in the event of
a fire. Use approved extinguishing agents instead. Do not use water to extin-
guish fires.
Please inform your vehicle manufacturer if the height entered in your vehicle
documents needs to be altered due to the installation of the air conditioning
roof unit:
RT780 height: 169 mm
SP950 height: 60 mm
Disconnect all power supply lines when working on the air conditioning roof
unit (cleaning, maintenance, etc).
2.2 Handling electrical cables
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive materials
(metal).
Do not pull on the cables.
Attach and lay the cables in such a manner that they cannot be tripped over
or damaged.
The electrical power supply may only be connected by a specialist work-
shop.
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
Never lay power supply lines (battery leads) in the vicinity of signal or control
cables.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Target group CoolAir RT780, SP950T
6
3 Target group
This installation manual contains the essential information and instructions for
installing the parking cooler. It is intended for competent installer technical staff
who are familiar with the guidelines and safety precautions to be applied when
installing lorry accessories.
This installation manual should always be kept with the unit to which it relates.
4 Intended use
A
I
4.1 RT780
The installation kit enables the installation of a air conditioning roof unit CoolAir
RT780 in a roof opening (ventilation hatch) provided at the plant in a Renault
Trucks with a Day or Day & Night driver cab.
4.2 SP950
The installation kit enables the installation of a CoolAir SP950T roof evaporator
unit in a roof opening (ventilation hatch) provided at the plant in a Renault Trucks
with a Day or Day & Night driver cab.
The CoolAir SP950T roof evaporator unit can only be operated in combination
with a CoolAir SP950C condenser unit. Both components together form the
CoolAir SP950 parking cooler.
NOTICE!
The device is not suitable for installation in construction machines,
agricultural machines or similar equipment. They will not work properly if
exposed to strong vibrations.
Operating the device with voltages other than those specified can result in
damage to the devices.
NOTE
The device is only designed for ambient temperatures of up to 43 °C.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
7
EN
CoolAir RT780, SP950T Scope of delivery
5 Scope of delivery
5.1 RT780
CoolAir RT780 installation kit for
Renault Trucks Day and Day & Night driver cab
Item in
fig. 1
Part designation Quantity Ref. no.
. Thread insert with flange M8 14 4445200068
3 Spacer sleeve L = 18 mm, 14 mm 8 4443900236
$ Adapter for cover frame 2 4442500796
/ Rounded head screw M8 x 16 6 4445200048
1 Washer 8,5 x 20 x 1,25 8 4445200113
4 Spring washer M8 8 4445200091
2 Hex screw M8 x 40 8 4445200106
( Spacer sleeve L = 48 mm, 10 mm 4 4443900241
, Spacer sleeve L = 39 mm, 10 mm 4 4443900339
" Cover frame 1 4443000355
 Nut M4 4 4445200055
 Washer M4 4 4445200120
 Washer M6 4 4445200115
 Allen screw with cylindrical head M4 x 100 4 4445200092
 Cap for cover frame 1 4443000357
Allen screw with cylindrical head M6 x 12 4 4445200119
 2.5 m insulating tape (profile: 10 x 20 mm) 1 4443300055
 Connection cable 6 mm² x 11 m 1 4441300149
 Cable binder 1 4445900256
 1/4" hexagon bit 1 4445900172
Installation manual 1 4445102179
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Accessories CoolAir RT780, SP950T
8
5.2 SP950
CoolAir SP950T installation kit for
Renault Trucks Day and Day & Night driver cab
6 Accessories
Available as accessories (not included in the scope of delivery):
Item in
fig. 1
Part designation Quantity Ref. no.
. Washer M8 8 4445200117
3 Spacer sleeve L = 18 mm, 14 mm 8 4443900236
$ Adapter for cover frame 2 4442500796
/ Rounded head screw M8 x 16 6 4445200048
1 Washer 8,5 x 20 x 1,25 8 4445200113
4 Spring washer M8 8 4445200091
2 Hex screw M8 x 45 8 4445200107
( Spacer sleeve L = 48 mm, 10 mm 4 4443900241
, Spacer sleeve L = 39 mm, 10 mm 4 4443900339
" Cover frame 1 4443000355
 Nut M4 4 4445200055
 Washer M4 4 4445200120
 Washer M6 4 4445200115
 Allen screw with cylindrical head M6 x 100 4 4445200092
 Cap for cover frame 1 4443000357
Allen screw with cylindrical head M4 x 12 4 4445200119
 2.5 m insulating tape (profile: 10 x 20 mm) 1 4443300055
 Connection cable 6 mm² x 11 m 1 4441300149
 Cable binder 1 4445900256
Installation manual 1 4445102179
Part designation Ref. no.
Connection cable 8 mm² x 9.5 m 9100300027
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
9
EN
CoolAir RT780, SP950T Installation
7 Installation
!
A
7.1 Notes on installation
The following tips and instructions must be observed wile installing the air
conditioning roof unit:
!
Before installing the parking cooler, check whether any vehicle components
could be damaged or have their function impaired as a result of the installa-
tion.
Check the dimensions of the system to be installed (fig. 2).
The dotted line indicates the middle of the roof hatch opening.
Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of
the parking cooler when the vehicle is in motion. The manufacturer of the air
conditioning roof unit assumes no liability whatsoever.
The roof inclination of the mounting surface may not exceed 8° in the
direction of travel.
The supplied assembly parts must not be modified during installation.
CAUTION!
Improper installation of the air conditioning roof unit can result in irreparable
damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning roof
unit is not installed according to this installation manual. That applies to mal-
functions and the safety of the air conditioning roof unit, in particular to injuries
and damage to property.
NOTICE!
The air conditioning roof unit may only be installed by qualified personnel
from a specialist company. The following information is intended for
technicians who are familiar with the guidelines and safety precautions to
be applied.
The manufacturer only assumes liability for parts included in the scope of
delivery. The validity of the warranty expires if the device is installed
together with third-party parts.
Check whether the roof of the vehicle is able to support the weight of a
person before climbing onto it. Ask the vehicle manufacturer about the
permitted roof loads.
WARNING!
Make sure that all electrical components are electrically discharged before
carrying out work on them.
Before installing the parking cooler, disconnect all connections to the vehicle
battery.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Installation CoolAir RT780, SP950T
10
The ventilation slots (grill) may not be covered (minimum distance from other
attachment parts: 10 cm).
You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. On some
vehicles, larger consumers connected to the terminal block are switched off
after a short while if the power requirement is too high. Ask your vehicle
manufacturer for the specifications of the terminal block.
When installing the system and making the electrical connections, observe
the guidelines from the body manufacturer.
Pay attention to the connection plan for the device:
RT780
No. in
fig. 5
Designation
1Control pad
2 Connection cable
3 Room temperature sensor
4Earth
5 Klickson (compressor)
6Compressor
7Condenser fan
8Vaporiser fan
9Earth
10 25 A fuse
11 2 A fuse
12 4 A fuse
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
11
EN
CoolAir RT780, SP950T Installation
SP950
I
7.2 Removing the sunroof
Proceed as follows (fig. 6):
Remove all screws and fixtures of the existing sunroof.
Take out the sunroof.
Remove the sealant around the opening, so that the surface is clean and free
of grease.
I
No. in
fig. 5
Designation
1 Condensate pump
2Evaporator fan
3 Operating circuit board
4 Temperature sensor
5 Level sensor
6 Control unit
725 A fuse
8 4 A fuse vaporiser fan
9 4 A fuse condenser fan
10 Condenser fan
11 Compressor
12 Klickson (compressor)
bl br gl gr ro sw w
Blue Brown Yellow Green Red Black White
NOTE
After installing the unit, the specified parameters of the unit software must be
checked (chapter “Configuration of unit software” on page 15).
NOTE
Dispose of all waste material, glue, silicone and seals separately. Observe the
local disposal guidelines.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Installation CoolAir RT780, SP950T
12
7.3 Attaching the seal for the cab roof
A
Stick the insulating tape to the cab roof (fig. 7).
Provide the abutting edge and the top edge of the insulating tape with an
unhardened plastic butyl sealing compound (e.g. SikaLastomer-710).
7.4 Preparing the unit
A
Proceed as follows (fig. 8):
Place the air conditioning roof unit on a work surface with the housing facing
down.
RT780 only: Screw in the self-threading thread inserts in the corresponding
blind holes.
Fix the two sheet metals as shown.
7.5 Installing the unit in the sunroof
Set the unit down centrally aligned and in the direction of travel (fig. 9) on
the sunroof opening.
I
A
Fix the parking cooler in place as illustrated (fig. 0)
NOTICE!
Ensure that the adhesive surface for the seal between the unit and the cab roof
is clean (free of dust, oil, etc.).
NOTICE!
During preparatory work on the surfaces, secure the unit from falling down.
Make sure that the work surface is clean and level to ensure that the unit is
not damaged.
Do not exceed the specified torque under any circumstances. This is the
only way to ensure that the thread inserts are not torn out.
NOTE
Make sure the air conditioning roof unit is centred perfectly. The seal must be
applied continuously around the air conditioning roof unit after being placed
on the roof of the vehicle. This is the only way to ensure a tight seal.
NOTICE!
Do not exceed the specified torque under any circumstances. This is the only
way to ensure that the thread inserts are not torn out.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
13
EN
CoolAir RT780, SP950T Installation
7.6 Installing the electrical supply lines
!
A
I
You can connect the unit to the battery via the lorry's terminal block or directly.
The terminal block is to be preferred for the connection. Ask your vehicle
manufacturer for the specifications of the terminal block.
Proceed as follows (fig. b):
Lay the supply line and connect it to the vehicle (red line to plus, black line to
minus).
Plug in the supply line plug into the socket of the air conditioning roof unit
supply line.
To relieve strain on the supply line, secure it with a cable tie, e.g. to the cab
roof.
WARNING!
The electrical power supply may only be performed by qualified personnel
with specialist knowledge.
Make sure there is no voltage present on electrically operated components
before carrying out work on them!
NOTICE!
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
The battery must be able to supply the required current and voltage
(chapter “Technical data” on page 20).
Cut the connection cable to the shortest possible length. Otherwise the
voltage drop is increased and thereby the air conditioning roof unit‘s
performance reduced.
NOTE
The unit is equipped as standard with a 4 m long cable with a cross-section of
6mm
2
. If longer cable lengths are required, then the cable cross-section must
be increased by an authorised specialist workshop:
In this case cut off the cable as closely as possible to the unit (max. 0.5 m) and
then establish a suitable connection with a larger cable cross-section.
When the cable is extended by 4 m to 6 m in length, the manufacturer
recommends using a cross-section of at least 8 mm
2
.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Installation CoolAir RT780, SP950T
14
7.7 Installing supply lines to the condenser unit
(SP950Tonly)
Observe the following instructions when installing the supply lines:
Also observe the installation instructions for the condenser unit.
The maximum cable length between the evaporator and condenser unit is
4.20 m (fig. d).
When installing and bending supply lines, avoid narrow radii. Use a suitable
round object as a bending aid. A radius which is too narrow will buckle the
refrigerant line, and the parking cooler will be inoperable.
Shorten any supply line which is not needed by bending a curve.
Apply packing compound (fig. d 1) to prevent water entering between the
rear wall of the truck and the clip.
I
Fasten the supply lines to the rear wall of the truck using the clips provided
(fig. d).
Insert the corrugated piping in the holder provided (fig. d 2).
Put the cover on (fig. d 4).
7.8 Preparing the cover frame
A
If you do not have a cover made specifically for Renault Trucks available:
Fit the cap supplied in the cover frame as illustrated (fig. a).
7.9 Fastening the cover frame
A
Fix the cover frame in place as illustrated (fig. c).
NOTE
If you wish to avoid damaging the rear wall of the truck (drilling a hole), you can
also apply the clip using a suitable adhesive. Observe the instructions provided
by the adhesive manufacturer.
NOTICE!
Screw the screws in carefully order not to damage the cover frame.
NOTICE!
Screw the screws in carefully order not to damage the cover frame.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
15
EN
CoolAir RT780, SP950T Configuration of unit software
8 Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set at the
control panel (fig. 4):
I
8.1 Starting and ending configuration mode
The adjustable parameters can be changed in configuration mode:
When using the button to switch on the unit, hold both buttons +
and
pressed until the compressor LED flashes.
You are now in configuration mode.
The display version (e. g. “3.1S”) appears in the display for 2 seconds.
The first digit of the display shows the menu level and the second and third
digits show the parameters which can be set, e.g.
1.17 for menu level 1 and a
set target value of 17 °C.
I
Press the button to quit configuration mode.
Menu
level
Parameter Meaning
Default
setting
1 Set temperature The unit starts at the temperature
defined here.
20 °C (68 °F)
2Low voltage
cut-off
The battery monitor shuts down the unit
at the voltage defined here.
Characteristic
figure 4 =
22,8 V
3 Operating mode The unit starts with the operating mode
defined here.
0 = Auto-
matic mode
4 Default settings Parameters 1 – 3 can be reset to the
default settings.
--
5Temperature unit
display
The temperature can be displayed in °C
or °F.
°C
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is available.
NOTE
If you make no entry on the control panel for 60 seconds, the unit quits
configuration mode and shuts down.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
EN
Configuration of unit software CoolAir RT780, SP950T
16
8.2 Menu level 1: Set temperature
The unit always starts with a defined value for the room temperature. This
parameter can be configured between 17 and 30 °C (62 and 86 °F).
Start configuration mode (chapter “Starting and ending configuration mode”
on page 15).
The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
Press the button to change the parameters.
Use the +
and
buttons
to select the target value (in °C) at which the unit
should start operation.
The digits in the display flash until the parameter you entered is confirmed.
Press the button to confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 1 again and can use the +
and
buttons to switch
between menu levels.
576375HQDXOW+,VERRN6HLWH'RQQHUVWDJ-XQL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292

Dometic CoolAir RT780, SP950T Návod na inštaláciu

Typ
Návod na inštaláciu